04 6 8 10 10 ZZM Stations 04B Effective area of external silencer is 160 mm2.
Operating Note 3) 2-position 8-6:5, 8-8:6, 8-10:5 8-6:20, 8-8:15, 8-10:10 frequency cycle/sec. 3-position 8-6:3, 8-8:3, 8-10:2 8-6:10, 8-8:10, 8-10:20 Lubrication Not Required Manual override Non-locking push type Protection structure Dust Proof Coil rated voltage 100VAC, 110VAC, 200VAC, 220VAC, 24VDC Allowable voltage range % -15~ +10% of rated voltage Coil insulation Class B or equivalent
10 8 5 4 ZZMA Stations 04 ZQ 10 10 8 6 ZZMA Stations 04B Effective area of external silencer is 160 mm2.
Stations: 4 Stations, A, B Port: 04B (Side/Bottom, Side Plugged 1/2), SI Unit: 0 (w/o SI Unit), P, R Port Size: 10 (1), P, R Port Location: B (Both Sides), Thread: F (G)
Stations: 10 Stations, AB Port: 03L (3/8, Left), Thread: Rc, Control: None, PR Port: 04B (1/2, Both Sides)
Stations: 10 Stations, AB Port: 03R (3/8, Right), Thread: Rc, Control: None, PR Port: 04B (1/2, Both Sides)
Stations: 10 Stations, AB Port: 04R (1/2, Right), Thread: Rc, Control: None, PR Port: 04B (1/2, Both Sides)
Stations: 10 Stations, AB Port: 04R (1/2, Right), Thread: T (NPTF), Control: None, PR Port: 04B (1/2, Both Sides), PR Thread: T (NPTF), Silencer: SB (Silencer Box)
Stations: 10 Stations, AB Port: 03L (3/8, Left), Thread: T (NPTF), Control: None, PR Port: 04B (1/2, Both Sides), PR Thread: T (NPTF)
Stations: 10 Stations, AB Port: 03R (3/8, Right), Thread: T (NPTF), Control: None, PR Port: 04B (1/2, Both Sides), PR Thread: T (NPTF)
Stations: 10 Stations, AB Port: 04L (1/2, Left), Thread: T (NPTF), Control: None, PR Port: 04B (1/2, Both Sides), PR Thread: T (NPTF)
Stations: 10 Stations, AB Port: 04Y (1/2, Bottom), Thread: Rc, Control: None, PR Port: 04B (1/2, Both Sides)
Stations: 10 Stations, AB Port: 04L (1/2, Left), Thread: Rc, Control: None, PR Port: 04B (1/2, Both Sides)
-02 Round Square embedded type Round Square embedded type G46-10-02 G36-10-01 1.0MPa Note 3) GC3-10AS Note 2) GC3-10AS GC3-10AS 1 4 1 8 1 4 Note 1) Pressure gauge G46-2-02 G36-2-01 G46-2-02 Set pressure + 0.05MPa (at relief flow rate of 0.1l/min(ANR)) 5 to 60C (With no condensation) 5m 0.2MPa Note 3) GC3-2AS GC3-2AS GC3-2AS Note 4) AD48 N.O.
Specifications Model ISE35 Rated pressure range 0 to 1 MPa Display/setting pressure range 0.1 to 1 MPa ZSE20 ISE20 Withstand pressure 1.5 MPa ZSE30 ISE30 Minimum display/setting unit 0.01 MPa Applicable fluid Air, Non-corrosive gas, Non-flammable gas ZSE40 ISE40 12 to 24 VDC 10%, Ripple (p-p) 10% or less (With power supply polarity protection) Power supply voltage ZSE10 ISE10 Current consumption
AR10-A: Rc1/16
AR20-A to AR40-A, AR20(K)-B to AR60(K)-B, and AR20(K)-D to AR40(K)-D: Rc1/8
Old AR10: Rc1/16
Old AR20(K) to AR30(K): Rc1/8
Old AR40(K) to AR60(K): Rc1/4
Old AR1000: Rc1/16
Old AR2000 to AR3000: Rc1/8
Old AR4000 to AR6000: Rc1/4
The refreshed AR series with 2 digits and an “A” suffix (AR40-□□-A) was released in April 2012. The refreshed AR series with 2 digits and a “B” suffix (AR40-□□-B) was released in May 2012. And the new design AR series with 2 digits and a “D” suffix (AR40-□□-D) was released in October 2019.
AR10-A: Rc1/16
AR20-A to AR40-A, AR20(K)-B to AR60(K)-B, and AR20(K)-D to AR40(K)-D: Rc1/8
Old AR10: Rc1/16
Old AR20(K) to AR30(K): Rc1/8
Old AR40(K) to AR60(K): Rc1/4
Old AR1000: Rc1/16
Old AR2000 to AR3000: Rc1/8
Old AR4000 to AR6000: Rc1/4
Body Size: 40, Backflow: w/o Backflow Function, Thread: Rc, Port Size: 04 (1/2), Options: w/o Mounting Option, Set Pressure: 0.05 to 0.85 MPa Setting, Exhaust Mechanism: Relieving Type, Flow Direction: Left to Right, Knob: Downward, Pressure Units: Unit on Product Label: MPa, Pressure Gauge in SI Units: MPa
Body Size: 40, Backflow: w/o Backflow Function, Thread: Rc, Port Size: 1/2, Options: w/o Mounting Option, Set Pressure: 0.05 to 0.85 MPa Setting, Exhaust Mechanism: Relieving Type, Flow Direction: Left to Right, Knob: Downward, Pressure Units: Unit on Product Label: MPa, Pressure Gauge in SI Units: MPa, Made to Order: -