SMC Corporation of America
Elite Part Number Search
Search Results "25A-MXQ16-10C"

to 70C Ambient and fluid temperature With auto switch: 10C to 60C (No freezing) Auto switch specifications and the proper mounting positions for stroke end detection are the same as those for double acting, single rod type.

/Japanese 1 pc.), Y-strainer 20A 1 pc., Barrel nipple 20A 1 pc., Drain pan for the pump Weight (dry state) kg 151 154 Note 1) Use a 15% ethylene glycol aqueous solution if operating in a place where the ambient temperature and/or circulating fluid temperature is 10C or less.

Specifications Suction flow rate of vacuum suction type (Reference values) Bore size (mm) Item 20/25/32/40/50/63/80/100 1.5MPa 1.0MPa 0.05MPa Proof pressure Maximum operating pressure Minimum operating pressure Bore size Suction flow rate l/min (ANR) 20/25/32/40 50/63/80/100 10 20 Without auto switch: 10C to 70C With auto switch: 10C to 60C (No freezing) Ambient and fluid temperature 10-/

Trace the arrow mark , starting with the point A at the pressure dew point 10C to find the intersection B on the pressure characteristic line for 0.7 MPa. 2. Trace the arrow mark , starting with the point B to find the intersection C at the atmospheric pressure dew point. 3.

Trace the arrow mark , starting from point A at a pressure dew point of 10C to obtain the intersection B on the pressure characteristic line for 0.7 MPa. Trace the arrow mark , starting from point B to obtain the intersection C at the dew point under atmospheric pressure.

If the set temperature is repeatedly changed by 10C or more, the thermo-con may fail in short periods of time. Model Air flow [m3/min] Heat generation [W] HECR002-A 2 600 HECR004-A 5 1300 HECR006-A 5 1400 HECR008-A 7 1700 HECR010-A 7 2500 HECR008-W 0.2 200 HECR012-W 0.4 250 Operating Environment/Storage Environment Warning Facility Water Caution 1.

Low concentrations, however, can lead to freezing when circulating fluid temperature is 10C or lower and cause the thermo-chiller to break down. 5. A magnet pump or mechanical seal pump is used as the circulating pump for the circulating fluid.

25C MHZ2-6C/MHZA2-6C 140 Pressure 0.7 MPa Pressure 0.7 MPa 8 120 0.6 MPa 0.6 MPa Pressure 0.7 MPa Pressure 0.7 MPa Gripping force (N) Gripping force (N) 100 6 0.5 MPa 0.5 MPa 0.6 MPa 0.6 MPa 80 0.4 MPa 0.4 MPa 0.5 MPa 0.5 MPa F 4 60 0.3 MPa 0.3 MPa 40 0.4 MPa 0.4 MPa 2 0.25 MPa 0.25 MPa 20 0.3 MPa 0.3 MPa 0 10 20 30 0 20 40 60 80 100120 Gripping point L (mm) Gripping point L (mm) F MHZ2-10C

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com F MHZ2-10C/MHZL2-10C MHZ2-32C 250 Pressure 0.7 MPa Pressure 0.7 MPa Pressure Internal Grip Pressure 0.7 MPa Pressure 0.7 MPa 20 0.6 MPa 0.6 MPa 200 MHZA2, MHZ2, MHZL2 0.6 MPa 0.6 MPa Gripping force (N) Gripping force (N) 15 0.5 MPa 0.5 MPa 0.5 MPa 0.5

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com F MHZ2-10C/MHZL2-10C MHZ2-32C 250 Pressure 0.7 MPa Pressure 0.7 MPa Pressure Internal Grip Pressure 0.7 MPa Pressure 0.7 MPa 20 0.6 MPa 0.6 MPa 200 MHZA2, MHZ2, MHZL2 0.6 MPa 0.6 MPa Gripping force (N) Gripping force (N) 15 0.5 MPa 0.5 MPa 0.5 MPa 0.5

to 70C With auto switch: 10C to 60C (With no condensation) Proof pressure Max. operating pressure Min. operating pressure Mounting Bracket / Part No.

Suction Flow Rate of Vacuum Suction Type (Reference values) Specifications Bore size (mm) Item Bore size Suction flow rate L/min (ANR) 20/25/32/40 50/63/80/100 20 25 32 40 50 63 80 100 10 20 1.5 MPa 1.0 MPa 0.05 MPa Without auto switch: 10C to 70C With auto switch: 10C to 60C (No freezing) Proof pressure Maximum operating pressure Minimum operating pressure Ambient and fluid temperature Stroke

Fluid and fluid temperature Air: 10 to 60C (Dew point temperature: 10C or less) Withstand pressure 2.0 MPa Max. system pressure 1.0 MPa Ambient temperature 20 to 60C Valve leakage*1/External leakage*1 Air 1 cm3/min (ANR) or less Mounting orientation Unrestricted Enclosure*2 IP67 (IP65 for the DIN terminal) Standards*3 CE/UKCA Operating environment Location without the presence of corrosive

Refrigerant AFF AM UL certified product Improved corrosion resistance with the use of stainless steel, plate type heat exchanger (IDFB4E to 75E) AMD Power supply voltage: Single-phase 115 VAC (60 Hz) 230 VAC (60 Hz) Three-phase 460 VAC (60 Hz) AMH AME Air flow capacity SCFM (m3/h [ANR]) Series Rated inlet condition Port size Outlet air pressure dew point Note) AMF 37F(2.8C) 45F(7.2C) 50F(10C

Note 1) Use a 15% ethylene glycol aqueous solution if operating in a place where the ambient temperature and/or circulating fluid temperature is 50F (10C) or less. Note 2) Use fluid in condition below as the circulating fluid.

Lead wire length symbols: 0.5 m Nil (Example) M9NWV 1 m M (Example) M9NWVM 3 m L (Example) M9NWVL 5 m Z (Example) M9NWVZ D-X 427 A CK1 Series Specifications Bore size (mm) 50 40 63 Fluid Air Proof pressure 1.5 MPa Maximum operating pressure 1.0 MPa Minimum operating pressure 0.05 MPa Without auto switch: 10C to 70C With auto switch: 10C to 60C Ambient and fluid temperature Piston speed 50

. * Air purification rating: JIS B 8392-1 (ISO8573-1) Quality Degree 4, 4, 2 or more Bernoulli type XT661 X321 4C Outer body diameter: 4C 39 mm 6C 59 mm 8C 79 mm 10C 99 mm 4C 6C 8C 10C 120E 150E Bernoulli type Outer body diameter (mm) 39 59 79 99 l120 l150 Piping port size M5 x 0.8 Rc 1/8 XT661 X322 120E Fluid Air* Operating pressure 0.01 to 0.4 MPa Body size: l Proof pressure 0.6 MPa Ambient

Condition Condition Inlet air temperature 40C Inlet air temperature 55C Outlet air pressure dew point 10C Outlet air pressure dew point 10C Ambient temperature 35C Ambient temperature 35C Inlet air pressure 0.5MPa Inlet air pressure 0.7MPa Air flow 1200 l/min (ANR) Air flow 350 l/min (ANR) Power supply frequency 60Hz Power supply frequency 50Hz A = 0.85 based on conditions , and B-1 = 0.95

At the same ozone concentration of 1.1ppm, approximately 25% of the ozone still remains in the circuit as measured at point downstream of the mist separator (AM) at an atmospheric dew point of 10C. When the atmospheric dew point is 17C, approximately 45% of the ozone still remains.

Action Double acting Proof pressure 1.5 MPa Maximum operating pressure 1.0 MPa Minimum operating pressure 0.08 MPa 0.2 MPa Piston speed 50 to 500 mm/sec* 15 to 300 mm/sec* Ambient and fluid temperature Without auto switch: 10C to 70C With auto switch: 10C to 60C (No freezing) 5C to 60C Cushion Air cushion None Stroke length tolerance Up to 250: +1.0 0 , 251 to 1000: +1.4 0 , 1001 to 1500: