SMC Corporation of America
Elite Part Number Search
Search Results "53-SY5120-L3-01T-F2"

L1 = 25n + 63, L2 = 25n + 76, L3 = 25n + 269.5 (262.5) n: Stations 7 238 251 457 (435.5) 6 213 226 432 (410.5) 5 188 201 407 (385.5) 4 163 176 382 (360.5) 3 138 151 357 (335.5) 2 113 126 332 (310.5) 12 363 376 582 (560.5) 11 338 351 557 (535.5) 10 313 326 532 (510.5) 8 263 276 482 (460.5) 9 288 301 507 (485.5) L1 L2 L3 L3 ( ): Type MP 2-5-43 Series VQ4000 Construction Plug Lead Unit Metal

Series SX3000/5000/7000 Body Ported Valve Single Unit How to Order 5 L N SX 5 1 20 01 Series Bracket 3 SX3000 5 SX5000 Nil: Without bracket F1: With foot bracket 7 SX7000 Type of actuation 2 position single 1 2 position double F2: With side bracket 2 Manual override Nil: Non-locking push type 3 position closed center 3 Thread type Nil Rc 3 position exhaust center G F D: Push-turn locking

Save the displayed waveform screen (print screen). -53- 6.10 Display All Monitor List The method how to obtain the electric actuator condition is described with the display all function of the setup software. Click Monitor Display All of the setup software to display Display All window. The condition of each item is displayed.

L3 = 12.5 x M + 23 L4 = L3 10.5 L5 = (L3 L1)/2 n1: SY3000 Valve stations n2: SY5000 Valve stations 23 Tie-rod Base: For EX260 Integrated-type (For Output) Serial Transmission System Series SV RoHS How to Order Manifold EX260 SY SV VQC S0700 SS5V 10S1 D N 05 1 U W NA Enclosure IP67 Refer to Note 1) of the w SI unit specifications. w q e r y t u i q Series t P, E port entry r Valve stations

We=1.4xVaxWx10 L2 W2 M3=F3x L3 M= WexL =5xVaxWxL 3 F3 L3 W4 an= F = M = E Fmax Mmax Emax W3 F / M / E : Calculate Load / Momentum / Kinetic Energy Fmax / Mmax / Emax: Max. loading / momentum / kinetic energy under the condition of allowable speed (valve obtained from graph) Ek= W V2 2g Allowable Momentum & Maximum Loading

Load (kg) m1 m4 m2 m3 Moment (Nm) F3 M3=F3 x L3 L3 F1 M1=F1 x L1 F2 M2=F2 x L2 L1 L2 1. Maximum allowable load (1), static moment (2), and dynamic moment (3) (at the time of impact with stopper) must be examined for the selection calculations. Maximum allowable load To evaluate, use a (average speed) for (1) and (2), and (impact speed = 1.4a) for (3).

Load mass (kg) m1 m2 m3 Moment (Nm) M3 = F3 x L3 F3 M1 = F1 x L1 F1 M2 = F2 x L2 F2 L1 L2 L3 1. Maximum load mass (1), static moment (2), and dynamic moment (3) (at the time of impact with stopper) must be examined for the selection calculations. To evaluate, use a (average speed) for (1) and (2), and (impact speed = 1.4a) for (3).

Load (kg) m1 m4 m2 m3 Moment (Nm) F3 M3=F3 x L3 L3 F1 M1=F1 x L1 F2 M2=F2 x L2 L1 L2 1. Maximum allowable load (1), static moment (2), and dynamic moment (3) (at the time of impact with stopper) must be examined for the selection calculations. Maximum Allowable Load To evaluate, use a (average speed) for (1) and (2), and (impact speed = 1.4a) for (3).

Load (kg) m1 m4 m2 m3 Moment (Nm) F3 M3=F3 x L3 L3 F1 M1=F1 x L1 F2 M2=F2 x L2 L1 L2 1. Maximum allowable load (1), static moment (2), and dynamic moment (3) (at the time of impact with stopper) must be examined for the selection calculations. Maximum Allowable Load To evaluate, use a (average speed) for (1) and (2), and (impact speed = 1.4a) for (3).

Load weight (kg) m1 m2 m3 Moment (Nm) M3 = F3 x L3 F3 M1 = F1 x L1 F1 M2 = F2 x L2 F2 L1 L2 L3 1. Maximum load weight (1), static moment (2), and dynamic moment (3) (at the time of impact with stopper) must be examined for the selection calculations. To evaluate, use a (average speed) for (1) and (2), and (impact speed = 1.4a) for (3).

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com m4 m2 m3 Moment (Nm) F3 M3=F3 x L3 L3 F1 M1=F1 x L1 F2 M2=F2 x L2 L1 L2 1.

V100 SY (L5) Plug assembly 1 2 3 2-4.5 mounting hole (L4) SYJ VVQ100-12A(L3) 88 (8.5) L2 VK 48.7 L1 VZ Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VT (45) (35) 33 25 (5.5) 23.5 VP 12.3 VG R11 (Min. bending inner radius) Manual override 21.5 (29.3) VP 104 S070

Stations Stasions 3 2 1 Dside Uside 02 2 stations VVQ1000-10A-2 20 20 stations Port size and thread 01N 01T 01F M5, Rc(PT)1/8 NPT1/8 NPTF1/8 G(PF)1/8 Only thread port size 1/8 style (2U type, P/E port) has choice of thread.

Stations U side D side 2 stations 02 VVQ1000-10A-2 Stations4321 20 stations 20 Port size and thread M5, Rc 1/8 NPT 1/8 NPTF 1/8 PF 1/8 Nil 01N 01T 01F Only thread port size 1/8 type, (Type 2U, P/E port) has choice of thread.

Stations U side D side 2 stations 02 VVQ1000-10A-2 Stations4321 20 stations 20 Port size and thread M5, Rc 1/8 NPT 1/8 NPTF 1/8 PF 1/8 Nil 01N 01T 01F Only thread port size 1/8 type, (Type 2U, P/E port) has choice of thread.

Please also note: That brackets F1, F2 cannot be mounted. Caution How to Order DIN connector Part No. Caution -12SY3000*-OMJ0003-A Specific Product Precautions 6 Be sure to read before handing.

Measurement mode] 25 Change of Set Value [3 step setting mode] 26 Default setting 26 Change of Set Flow and Hysteresis [Simple setting mode] 31 Simple setting mode 29 Change the Function Settings [Function selection mode] 31 Function selection mode 31 Default setting 32 F0 Reference condition/Units selection function/Switch output function/ Output object/Display colour 33 F1 Setting of OUT1 37 F2

We=1.4xVaxWx10 L2 W2 M3=F3x L3 M= WexL =5xVaxWxL 3 F3 L3 an= F W4 Fmax W3 F : Calculated load Fmax : Maximum allowable load under the condition of allowable speed (value obtained from graph) Ek= W V2 2g Allowable moment and maximum load Model Allowable moment N.m Maximum load N M1 M2 M3 W1 W2 W3 W4 ML2B25 10.0 1.2 3.0 200.0

Moment (Nm) Moment (Nm) Moment (Nm) Load mass (kg) M1 = F1 x L1 Piston speed V (mm/s) ML1C/M2, M3 M2 = F2 x L2 M3 = F3 x L3 Piston speed V (mm/s) (How to calculate the load ratio) A. Consider (1) max. load mass, (2) static moment, (3) dynamic moment (when stopper collides) when calculating the max. allowable moment and load mass.

Load weight (kg) Caution The cylinder should be mounted in m1 orientation if maximum dustproofing is required. m m m Moment (Nm) M = F x L F3 M = F x L M = F x L F F2 L2 L1 L3 Maximum load weight Select the load weight from within the range of limits shown in the graphs. Note that the maximum allowable moment value may sometimes exceed even the operating limits shown in the graphs.