Air pressure supplied from A operates on surfaces 1 and 2. (extension) A B Air pressure supplied from B operates on surface 3. (retraction) A B Mounting accuracy improved Positioning holes are provided on the work piece mounting surface for easy alignment. Regulator with check valve is unnecessary A regulator with check valve normally required for a lifting circuit becomes unnecessary.
Body Size: 40, Thread: F (G), Port Size: 06 (3/4), Mounting: None, Semi-Standard, Body Size 10: Standard, Semi-Standard, Body Size 20: Standard, Semi-Standard, Body Size 30, 40, 50 & 60: Standard
Min. Dripping Flow Rate(l/min): 50, Oil Storage Capacity(cm3): 135, Case: [Resin] Polycarbonate Case, Inlet Side Connection Type: G, Inlet Side Plumbing Thread Nominal: 3/4, Outlet Side Connection Type: G, Outlet Side Plumbing Thread Nominal: 3/4, Drain Exhaust: [Not Provided] No Drain Cock, Flow Direction: [Right] From Left to Right, Size of Body: 40, Accessory: Without optional
Table 3.8-2 RTU mode message frame Address c)Function d)Data e)Checksum a)Start b)Device (CRC) f)End T1-T2-T3-T4 XX XX XX XX XX XX T1-T2-T3-T4 a) Start In Modbus RTU mode, message frames are separated by a silent interval (noncommunication time).
40 A 4 cores x 8 mm2 (4 cores x AWG8) (Including grounding cable) R8-5 HRSH250--20 50 A 4 cores x 8 mm2 (4 cores x AWG8) (Including grounding cable) R8-5 M5 A HRSH100--40 20 A 3 x 5.5 mm2 (3 x AWG10) (Power supply) 1 x 14 mm2 (1 x AWG6) (Grounding cable) R5.5-5 (Power supply) R14-5 (Grounding cable) HRSH150--40 HRSH200--40 HRSH250--40 3-phase 380 to 415 VAC (50/60 Hz) 30 A Note) An example
HRX-OM-W069-A Operation Manual Communication function Thermo-chiller Air-Cooled refrigerated type HRL100-A HRL200-A HRL300-A Keep this manual available whenever necessary 2023 SMC CORPORATION All Rights Reserved To Users, Thank you for purchasing SMCs Thermo chiller (hereinafter referred to as the product).
Cable size Crimped terminal on the thermo-chiller side Applicable model HRS100-A -20HRS100-W -204 cores x 5.5 mm2 (4 cores x AWG10) (Including grounding cable R5.5-5) R5.5-5 3-phase 200 VAC (50 Hz) 3-phase 200 to 230 VAC (60 Hz) 30 A M5 HRS150-A -20HRS150-W -2040 A 4 cores x 8 mm2 (4 cores x AWG8) (Including grounding cable R8-5) R8-5 A HRS100-A -40HRS100-W -403-phase 380 to 415 VAC (50/60
If the actual flow rate is lower than this, install a bypass piping. Note 8) To be prepared by user. A specified earth leakage breaker is installed for option B [With earth leakage breaker] and B1 [With earth leakage breaker with handle].
30 20 Applicable earth Note 8) Sensitivity of leak current mA 30 Rated operating current Note 5) A 15 8 Rated power consumption Note 5) kW (kVA) 4.6 (5.2) 5.0 (5.6) Noise level (Front 1 m/Height 1 m) Note 5) dB (A) 66 Accessories Alarm code list stickers 2 pcs.
No anchor bolt is included. 77 A HRS090 Series Standard Type Cooling Capacity HRS090-A-20/40 (50 Hz) HRS090-A-20/40 (60 Hz) 12 12 10 10 Ambient temperature 32C Ambient temperature 32C Cooling capacity [kW] Cooling capacity [kW] 8 8 Ambient temperature 40C Ambient temperature 40C 6 6 4 4 Ambient temperature 45C Ambient temperature 45C 2 2 0 0 5 10 15 20 25 30 35 Circulating fluid temperature
Q G RS H A RZQ ZZ + Stroke MI W S CEP1 CE1 (mm) CE2 AL B1 B2 D E F G H H1 H2 I K MM N NA NN P S ZZ A Bore size (mm) 20 25 32 40 0 0.033 0 0.033 0 0.033 0 0.039 18 15.5 13 26 8 13 8 41 5 8 28 5 M8 x 1.25 15 24 M20 x 1.5 1/8 62 116 20 ML2B 22 19.5 17 32 10 13 8 45 6 8 33.5 5.5 15 30 M26 x 1.5 1/8 62 120 M10 x 1.25 26 22 19.5 17 32 12 13 8 45 6 8 37.5 5.5 15 34.5 M26 x 1.5 1/8 64 122 M10 x 1.25
Applicable bore size A D L MM N R W Flat type Round type CJ-CF010 CJ-CR010 10 8 10 13 M4 x 0.7 6 10 8 Part no.
3 O-ring NBR u 15-9-105 15 Dimensions L4 D3 H (He (Hexagon width across flats) xagon width across flats) (Hexagon width across flats) T2 A L2 D1 L3 D2 T1 L1 Dimensions AS120-U10/32-T 10-32 UNF 10-32 UNF AS120-M5-T M5 x 0.8 M5 x 0.8 Model T2 H D1 T1 D2 D3 L1 L2 L3 L4 A 27.4 0.7 10.3 31 10 4.5 9 8 9 AS220-N01-ST NPT 1/8 NPT 1/8 AS220-F01-ST G 1/8 AS220-01-ST Rc 1/8 R 1/8 12 14.3 31.6 1.5 14.1
ME MB RR RB MA MD MT E + Stroke A + (Stroke x 2) MC (RA) (mm) Bore size A E MA MB MC MD ME MT RA RB RR 90 12 16 20 25 32 40 33 RJ0806H M12 x 1.5 6 8 27 13 19 7 51 RJ0806H M12 x 1.5 6 33 28 16 19 8 7 58 94 RJ1007H M14 x 1.5 37 33 22 8 10 9 68 30 109 M14 x 1.5 37 RJ1007H 25 8 10 41 82 30 109.5 9 M20 x 1.5 RJ1412H 32 8 55 51 100 38 12 9 135.5 RJ1412H M20 x 1.5 8 55 60 32 38 12 9 108 142 -X -
8 @0 @2 @3 !6 q !5 !9 i *1 *1 C95K32 A A-A A !2 !
B A B A B A B A B A B A B A B A B 40 50 63 80 100 6 4 3.5 1.5 0 0.5 6.5 2 4 11.5 10 0 0 4.5 0 2 9.5 8 ML2B 3.5 1.5 0 0.5 6.5 2 4 11.5 10 0 0 4.5 0 2 9.5 8 8.5 7.5 6 5 2.5 3 9 4.5 6.5 14 12.5 1.5 2 8 3.5 5.5 13 11.5 12 10 9.5 7.5 6 6.5 4.5 8 10 17.5 16 4 4.5 12.5 6 8 15.5 14 13.5 12.5 11 10 7.5 8 14 9.5 11.5 19 17.5 6.5 7 13 8.5 10.5 18 16.5 D-A9 and D-A9V cannot be mounted on 50.
B A B A B A B A B A B A B Hs Hs Hs Hs Ht Hs Ht Hs Hw Hs Hw 0 (0) 0 (0) 0 (2.5) 2 (6) 4 (7.5) 1 (0) 1 (0) 5.5 (1.5) 8.5 (4) 10.5 (6.5) 0 (0.5) 0 (0.5) 0 (3) 2.5 (6.5) 4.5 (8) 4.5 (1.5) 4.5 (1.5) 9 (5) 12 (7.5) 14 (10) 0 (2) 0 (2) 1 (4.5) 4 (8) 6 (9.5) 3 (0) 3 (0) 7.5 (3.5) 10.5 (6) 12.5 (8.5) 1 (4) 1 (4) 3 (6.5) 6 (10) 8 5 (2) 5 (2) 9.5 (5.5) 12.5 (8) 14.5 7.5 8.5 1.5 (0) 1.5 (0) 6 (2) 9 (
8@0!7 !9i @2 q r y#0 $0 $2 w $3 #8 @9 A C B Section A !2 !2 #4 @6 #9 @8 $4 #2 #1 #6 #7 $6 !0 u @5 !6 @1 !1 $7 o $8 e $1 !2 Section B Section C 100 80 63 50 40 32 80, 100 80, 100 Description Material Note Parts list Description Material Note Parts list No. No.
Height Auto Switch Mounting Position (mm) D-F5W D-J59W D-F5 D-J5 D-F5BAL D-F59F D-Z7, Z80 D-Y59, Y69 D-Y7P, Y7PV D-Y7W, D-Y7WV D-Y7BAL D-A3 D-A44 D-G39 D-K39 D-A5 D-A6 D-A59W D-F5NTL D-F5LF D-P5DWL Bore size (mm) A A A A B A A A A B B B B B B B 32 12 11 7 4.5 0 0.5 3.5 4 0.5 9.5 8.5 4.5 2 1 1.5 0 40 12 11 7 4.5 0 0.5 3.5 4 0.5 9.5 8.5 4.5 2 1 1.5 0 50 12.5 11.5 7.5 5 0 1 4 4.5 1 10 9 5 2.5