SMC Corporation of America
Elite Part Number Search
Search Results "CD85E10-100-A-M9PV"

Measurement circuit of cylinder output relative to supply pressure CQ2B40-75D (Standard) CQ2XB40-75D (Low speed cylinder) RE A B [Example of test method] The test sample is in place in an acrylic chamber. The chamber is set up on a Class 100 clean bench. The solenoid valve is operated while supplying a volume of clean air equal to the intake volume of a laser dust monitor (28.3 l/min).

(Note: Reed auto switches for 100 VAC and 100 VDC are not within the specification.

(Compared with a C(P)95N, 100, 100 mm stroke) Applicable rod size: 12 to 30 CAT.ES20-259A CP96N/C96N Series Cylinder with Lock CP96N/C96N Series A locking cylinder ideal for intermediate stops, Overall length reduced by 27.5 mm max.

When the product repeatedly cycles with partial strokes (100 mm or less), lubrication can run out. Operate it at a full stroke at least once a day or every a thousand cycles. 5. Do not apply strong impact or an excessive moment while mounting the product or a workpiece.

Do not apply strong impact or an excessive moment while mounting the product or a workpiece. 2. When the product repeatedly cycles with partial strokes (100 mm or less), lubrication can run out. Operate it at a full stroke at least once a day or ev ery a thousand cycles.

mm stroke For 125 mm stroke For 150 mm stroke For 75 mm stroke For 100 mm stroke For 125 mm stroke For 150 mm stroke For 175 mm stroke 32 40 50 63 80 100 Dimensions CHKGB--XC63 Stroke Bore size (mm) 55, 60, 65, 70 80, 85, 90, 95 105, 110, 115, 120 130, 135, 140, 145 155, 160, 165, 170 Dimensions A B A B A B A B A B 32 141 131 166 156 191 181 216 206 40 150 140 175 165 200 190 225 215 250

4.5 7 6 8 10 14.5 A 15.5 24 24 26 29 32.5 B 9.5 12 11 13 15 19.5 A 16 16 18 21 24.5 B 4 3 5 7 11.5 A 12.5 12.5 14.5 17.5 21 B 0.5 0 1.5 3.5 8 A 16.5 16.5 18.5 21.5 25 B 4.5 3.5 5.5 7.5 12 32 40 50 63 80 100 32 40 50 63 80 100 Note 1) D-M9, M9V, M9W, M9WV, M9A, M9AV cannot be mounted to 100.

Related Products DDimensions B + Stroke A + Stroke (mm) A 55 to 100 mm strokes B 55 to 100 mm strokes Bore size (mm) 32 40 50 63 80 100 65 67 76 80 89 95 73.5 75.5 87 91 100 107 Dimensions other than the above are the same as the standard double acting single rod type.

(mm/s) : Distance to the loads center of gravity (m) : Dynamic moment (Nm) : Gravitational acceleration (9.8 m/s2) m FE ME L1 3 1.4 100 1 3 Note 4) a is a dimensionless coefficient for calculating impact force.

The following graphs show the displacement at point A, which is 100 mm apart from the center of rotation, where the load is applied.

Use a power source separate from large motors and AC valves, etc. 3. Run the stroke reading cylinders cable away from other power lines. 4. Install a noise filter in the 100 VAC power line, and install a varistor in the DC power supply of the sensor cable. 2. Operate the cylinder in such a way that the load is always applied in the axial direction.

Use a power source separate from large motors and AC valves, etc. 3. Run the stroke reading cylinders cable away from other power lines. 4. Install a noise filter in the 100 VAC power line, and install a varistor in the DC power supply of the sensor cable. 2. Operate the cylinder in such a way that the load is always applied in the axial direction.

Use a power source separate from large motors and AC valves, etc. 3. Run the stroke reading cylinders cable away from other power lines. 4. Install a noise filter in the 100 VAC power line, a varistor in the DC power supply of the sensor cable and a ferritic core in the signal line (sensor cable). 2.

100 64 62 53.4 7.5 M6 x 1 32 29.7 8 50 6.6 M8 x 1.25 50 0.2 46 10 to 100 77 74 59.6 7.5 M6 x 1 38.5 35.4 8 60 9 M10 x 1.5 54 Note 1) The dimensions (A + stroke) and (B + stroke) for 5 mm stroke will be the same as those for 10 mm stroke.

A DAdjustment range by adjustment bolt B Adjustment range by adjustment bolt B Adjustment range by adjustment bolt B 90 Rotation 90 Rotation 90 Rotation 335 MSQX Series Table Displacement (Reference values) The following graphs show the displacement at point A, which is 100 mm apart from the center of rotation, where the load is applied. 100 Load Arm A Displacement MSQXB10A MSQXB20A 300

A A F F A F MX L L L L = 100 mm 8 L = 100 mm 8 MTS MXP8-10 MXP8-10 MXP8-20 MXP8-20 MXP8-10 MXP8-20 8 L = 100 mm 0.03 0.04 MY 0.06 Table displacement (mm) Table displacement (mm) Table displacement (mm) MXP8-10 MXP8-10 MXP8-20 MXP8-20 MXP8-10 MXP8-20 0.05 MXP8-10 MXP8-10 MXP8-20 MXP8-20 MXP8-10 MXP8-20 0.03 CY 0.02 0.04 0.02 0.03 MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South

RS Q G Theoretical Output Rotary Angle (N) RS H A Operating pressure (MPa) Piston area (cm2) Bore size (mm) Rod size (mm) Operating direction 1.0 0.7 0.5 0.3 RZQ Release (Extended stroke end) 80 to 100 (90 10) Counterclockwise (L) Release (Extended stroke end) 80 to 100 (90 10) Clockwise (R) 80 56 40 24 0.8 R 12 6 110 77 55 33 1.1 H MI W S 150 105 75 45 1.5 R 16 8 200 140 100 60 2 H CEP1

9200-www.stevenengineering.com When tightening an auto switch mounting screw, use a watchmakers screwdriver with a grip diameter of 5 to 6 mm.

23.4 74.7 50.2 64.7 26.7 40.2 24.7 16.7 14.7 Solid State Switch: D-M9BV, D-M9NV, D-M9PV, D-F9WV (mm) B E B Stroke Model Stroke A 100 75 50 30 20 10 100 75 50 30 20 10 MXF8 13.5 6 1 6 14 9 14 MXF12 16 25.1 9.1 9.1 33.1 17.1 17.1 MXF16 21.2 42.3 21.8 11.8 50.8 29.8 19.8 MXF20 23.4 66.7 42.2 18.7 16.7 74.7 50.2 26.7 24.7 ( ): Denotes the values of D-A93.