SMC Corporation of America
Elite Part Number Search
Search Results "CDBA2F50-350-HN-A54"

, 400, 450, 500 C95 40 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500 50 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 CA1 63 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 CS1 80 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 100 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450

Note 3) For mounting types FY, FZ, or TA, indicate port position with the symbol B. 5 V, 12 V Water resistant (2-color indicator) M9PA 3-wire (PNP) 2-wire M9BA 12 V F59F 4-wire (NPN) 5 V, 12 V IC circuit Diagnostic output (2-color indicator) Z76 Z73 Z80 A54 5 V 3-wire (NPN equiv.)

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, TIE ROD, END LOCK, BOOT, ACTUATOR, CBA1/CBA2 TIE-ROD CYL END LOCK, NC, CBA1 50MM OTHERS (COMBO), 6.35390 lb

Load in the direction of rod extension Load in the direction of rod retraction Step x: Select graph n (Refer to page 7.) based upon the load conditions and operating pressure, and then from the intersection of the maximum speed V = 350 mm/s found in Step z, and the load mass m = 50 kg. \ 63 Select a C(P)96N63 or larger bore size. m 0.3 MPa Graph b F 0.4 MPa Graph n 0.5 MPa m Graph m

200 300 40 30 20 10 0 30 25 20 15 10 5 0 Load (N) Load (N) MSQXB30A MSQXB50A 350 300 300 250 Displacement (m) Displacement (m) 250 200 200 150 150 100 100 50 40 30 20 10 0 100 80 60 40 20 0 Load (N) Load (N) 336 MSQX Series Low-Speed Rotary Table Rack & Pinion Type Construction CRB2 CRB1 MSU CRJ CRA1 o i @5 @6 t y !

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence (Only Rod Side), Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port thread

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence (Only Rod Side), Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Port

Cylinder (Tube) Inner Diameter(φ): 160, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure(MPa): 0.08~0.97, Cushion: With

thread type: Rc, Auto Switches: A54, Lead Wire Length(m): 3, The number of the switches: 2, Type of Auto Switch Mounting: Standard, Rod End Bracket: None, Type of Mount Support: Rod-end flange type, Rod Boot: None, Custom-made Specifications: None, Customized specification (port positions): -, Type: Non-lube, Stroke adjustment symbol: -

thread type: Rc, Auto Switches: A54, Lead Wire Length(m): 5, The number of the switches: 2, Type of Auto Switch Mounting: Standard, Rod End Bracket: None, Type of Mount Support: Rod-end flange type, Rod Boot: None, Custom-made Specifications: Special port location, Customized specification (port positions): DB, Type: Non-lube, Stroke adjustment symbol: -

thread type: Rc, Auto Switches: A54, Lead Wire Length(m): 3, The number of the switches: 2, Type of Auto Switch Mounting: Standard, Rod End Bracket: None, Type of Mount Support: Foot, Rod Boot: None, Custom-made Specifications: None, Customized specification (port positions): -, Type: Lube type, Stroke adjustment symbol: -

thread type: Rc, Auto Switches: A54, Lead Wire Length(m): 3, The number of the switches: 2, Type of Auto Switch Mounting: Standard, Rod End Bracket: None, Type of Mount Support: Foot, Rod Boot: None, Custom-made Specifications: None, Customized specification (port positions): -, Type: Lube type, Stroke adjustment symbol: -

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,

Factors Table (see Table 1 on page 21), 50 9 15 30 66 96 130 determine the value of L. 60 14 18 57 88 119 2 In the left table, locate the previously determined thrust value. 80 12 16 36 71 104 10 14 22 57 90 3 Moving across the table, locate dimension L 120 12 21 45 77 (If the exact length is not shown, select the next larger value) 140 19 27 64 160 17 26 47 20 14 23 31 250 19 28 30 25 350

Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto

Factors Table (see Table 1 on page 21), 50 9 15 30 66 96 130 determine the value of L. 60 14 18 57 88 119 2 In the left table, locate the previously determined thrust value. 80 12 16 36 71 104 10 14 22 57 90 3 Moving across the table, locate dimension L 120 12 21 45 77 (If the exact length is not shown, select the next larger value) 140 19 27 64 160 17 26 47 20 14 23 31 250 19 28 30 25 350

Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches