Magnet: Built-in, Mounting: Front Flange, Bore Size: 32mm, Stroke: 50mm, Cushion: Rubber Bumper, Rod Boot: None, Lock Style: Rod Side Lock/Non-locking, Auto Switch: B54--Reed, DC Volt >5 <24, AC Volt <200, LED, Lead Wire, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in, Mounting: Front Flange, Bore Size: 32mm, Stroke: 50mm, Cushion: Rubber Bumper, Rod Boot: Nylon Tarpaulin, Lock Style: Rod Side Lock/Non-locking, Auto Switch: B54--Reed, DC Volt >5 <24, AC Volt <200, LED, Lead Wire, Lead Wire or Prewired Connector: -, Number: -
Magnet: Built-in, Mounting: Front Flange, Bore Size: 32mm, Stroke: 75mm, Cushion: Rubber Bumper, Rod Boot: None, Lock Style: Rod Side Lock/Non-locking, Auto Switch: C73--Reed, DC Volt >5 <24, AC Volt <100, LED, Lead Wire, Lead Wire or Prewired Connector: -, Number: -
Magnet: Built-in, Mounting: Front Flange, Bore Size: 32mm, Stroke: 75mm, Cushion: Rubber Bumper, Rod Boot: None, Lock Style: Rod Side Lock/Non-locking, Auto Switch: H7B--Solid State, Gen. Purpose, 2 Wire, Lead Wire, Lead Wire or Prewired Connector: -, Number: -
Magnet: Built-in, Mounting: Front Flange, Bore Size: 32mm, Stroke: 75mm, Cushion: Air Cushion, Rod Boot: None, Lock Style: Rod Side Lock/Non-locking, Auto Switch: C73--Reed, DC Volt >5 <24, AC Volt <100, LED, Lead Wire, Lead Wire or Prewired Connector: -, Number: -
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 35, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: Rubber cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Support bracket: -,
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: Air cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Support bracket: -, Auto
To enable the run/stop signal input or remote signal input, after wiring, set the item "Contact input signal 1 function selection" in "Communication setting menu" from "OFF (initial setting value)" to "RN .ST ". Tips This product has two input signals. These can be customized depending on the customers application. 1. Prepare a suitable connector cable. 2.
To enable the run/stop signal input or remote signal input, after wiring, set the item "Contact input signal 1 function selection" in "Communication setting menu" from "OFF (initial setting value)" to "RN .ST ". Tips This product has two input signals. These can be customized depending on the customers application. 1. Prepare a suitable connector cable. 2.
-c" urrent -;:--nge O I-road c t + ---_ In _t _ e_ rn _a _l _v _ o _ lt _ a ,, 9 ,, e_d _'_ 0 cP _ _ + _ ~ 0 I 2AVOf~ __ -Leak current 0 Response time 1.2 ms COJPB6-1OD _ In _d _ ic c.a :.. t_ o_ , _ Ia _ m ..: p _ _ + __ .---!'
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: Rubber cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Support bracket: -
Magnet: Built-in, Mounting: Front Flange, Bore Size: 32mm, Stroke: 125mm, Cushion: Rubber Bumper, Rod Boot: None, Lock Style: Rear End Lock Locking Style, Auto Switch: B54--Reed, DC Volt >5 <24, AC Volt <200, LED, Lead Wire, Lead Wire or Prewired Connector: 3m, Number: -
Magnet: Built-in, Mounting: Front Flange, Bore Size: 32mm, Stroke: 125mm, Cushion: Rubber Bumper, Rod Boot: None, Lock Style: Rear End Lock Non-locking Style, Auto Switch: C73--Reed, DC Volt >5 <24, AC Volt <100, LED, Lead Wire, Lead Wire or Prewired Connector: 3m, Number: -
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: Rubber cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Support bracket: -
Magnet: D (Built-in), Mounting: F (Front Flange), Bore Size: 32mm, Stroke: 125mm, Cushion: Rubber Bumper, Rod Boot: None, Lock Style: HN (Rear End Lock Non-locking Style), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Auto Switch Mounting Bracket:
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: Rubber cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Support bracket: With
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: Rubber cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Support bracket: With
To enable the run/stop signal input or remote signal input, after wiring, set the item "Contact input signal 1 function selection" in "Communication setting menu" from "OFF (initial setting value)" to "RN .ST ". Tips This product has two input signals. These can be customized depending on the customers application. 1. Prepare a suitable connector cable. 2.
ERR1 1 W RN PV < 3 1 . 6 C # 1 SV 3 0 . 0 C MODE No r ma l 4th line Indicates control operation mode during normal operation and set values during setting mode selection. Fig.4-3 Display 4.4 Reservoir Cap Reservoir Cap Removed to fill the recirculating fluid before operation.Replace cap before starting operation. Clockwise to open Counter-clockwise to close.
Without control unit, Bracket mounting) ISA-14 (Bracket when control unit not fitted) -20No.PS-OMR0002-K 2 About this product ISA3(Without control unit, DIN rail mounting) -21No.PS-OMR0002-K 2 About this product ISA3-B-L (With control unit, Bracket mounting) Regulator ISA3-B-L Regulator -22No.PS-OMR0002-K 2 About this product ISA3-B-R ISA3-B-R Regulator Regulator ISA3---B-LN ISA3---B-RN