100) (80 and 100) (80 and 100) Black zinc chromated Seal list No.
Wn Mass mn A = 27 100 X-axis xn Y-axis yn Z-axis zn 25 O 50 Wa Wb Wc Wd 1.0 kg 0 mm 0 mm 5 mm 5 50 Y 1.0 kg 0 mm 0 mm 50 mm 0.5 kg 0 mm 25 mm 100 mm 3.0 kg 0 mm 50 mm 100 mm n = a, b, c, d Z X [3] Calculation for Overall Center of Gravity mt = mn = 1.0 + 1.0 + 0.5 + 3.0 = 5.5 kg = 0 mm X (The center of gravity in the x direction of all work pieces is 0, so X = 0 mm.)
TEMP READY function setting example [1] Circulating fluid temperature at start of operation: about 20 C [2] Circulating fluid setting temperature: 15 C [3] "TEMP READY Bandwidth (Upper Limit)": Set to "2.0 C". [4] "TEMP READY Bandwidth (Lower Limit)": Set to "-2.0 C". [5] "TEMP READY stabilization time": set to "60 sec". [6] "TEMP READY monitoring start time": set to "30 sec". [7] "Time
Table 3-1 Amount of radiation and required ventilation Required ventilation amount (m3/min) Heat Differential temp. of 3 C between inside Differential temp. of 6 C between inside radiation Model (kW) and outside of and outside of installation area installation area HRR012-A-10/20Approx.2 40 20 HRR018-A-10/20Approx.4 70 40 HRR024-A-10/20Approx.5 90 50 HRR030-A-10/20Approx.6 100 60 3.2 Installation
Refer to p.0-39 to 0-46 for Safety Instructions and common precautions, and refer to p.3.4-2 for precautions on series CB. 75 20 80 90 2 Same side 100 100 100 100 D-A3C D-G39C D-K39C 20+35(n2) n=2, 3, 4, 80+35(n2) n=2, 4, 6, 8, 75+35(n2) n=2, 4, 6, 8, 90+35(n2) n=2, 4, 6, 8, Dif. sides n 100+100(n2) Same side 100+100(n2), n=2, 4, 6, 8, n=2, 3, 4, 5, 90 10 80 75 1 Replacement Dif. sides
Refer to p.0-39 to 0-46 for Safety Instructions and common precautions, and refer to p.3.8-2 for precautions on series CB. 75 20 80 90 2 Same side 100 100 100 100 D-A3C D-G39C D-K39C 20+35(n2) n=2, 3, 4, 80+35(n2) n=2, 4, 6, 8, 75+35(n2) n=2, 4, 6, 8, 90+35(n2) n=2, 4, 6, 8, Dif. sides n 100+100(n2) Same side 100+100(n2), n=2, 4, 6, 8, n=2, 3, 4, 5, 10 80 75 90 1 Replacement Dif. sides
TEMP READY function setting example [1] Circulating fluid temperature at start of operation: about 20 C [2] Circulating fluid setting temperature: 15 C [3] "TEMP READY Bandwidth (Upper Limit)": Set to "2.0 C". [4] "TEMP READY Bandwidth (Lower Limit)": Set to "-2.0 C". [5] "TEMP READY stabilization time": set to "60 sec". [6] "TEMP READY monitoring start time": set to "30 sec". [7] "Time
Table 8-1 Quality standard for clean water (tap water) Standard value Item Unit For circulating fluid For facility water pH (at 25oC) 6.0 to 8.0 6.5 to 8.2 Electric conductance (at 25oC) [S/cm] 100 to 300 100 to 800 Chloride ion [mg/L] 50 or less 200 or less Sulfuric acid ion [mg/L] 50 or less 200 or less Standard item Acid consumption (at pH 4.8) [mg/L] 50 or less 100 or less Total hardness
Magnet: D (Built-in), Mounting: L (Axial Foot), Bore Size: 32mm, Stroke: 300mm, Cushion: Rubber Bumper, Rod Boot: None, Lock Style: WN (Lock on Both Sides Non-locking)
Magnet: D (Built-in), Mounting: L (Axial Foot), Bore Size: 32mm, Stroke: 50mm, Cushion: Rubber Bumper, Rod Boot: None, Lock Style: WN (Lock on Both Sides Non-locking)
Magnet: D (Built-in), Mounting: L (Axial Foot), Bore Size: 32mm, Stroke: 250mm, Cushion: A (Air Cushion), Rod Boot: None, Lock Style: WN (Lock on Both Sides Non-locking)
Magnet: D (Built-in), Mounting: L (Axial Foot), Bore Size: 32mm, Stroke: 25mm, Cushion: A (Air Cushion), Rod Boot: None, Lock Style: WN (Lock on Both Sides Non-locking)
Magnet: D (Built-in), Mounting: L (Axial Foot), Bore Size: 32mm, Stroke: 200mm, Cushion: A (Air Cushion), Rod Boot: None, Lock Style: WN (Lock on Both Sides Non-locking)
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: Rubber cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Support bracket: -,
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: [Included] Presence, Cushion: Rubber cushion, Operating Pressure(MPa): 0.15 to 1.0, Specification: Built-in magnet, Support bracket: -,
Magnet: Built-in, Mounting: Axial Foot, Bore Size: 32mm, Stroke: 300mm, Cushion: Rubber Bumper, Rod Boot: None, Lock Style: Lock on Both Sides Non-locking, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -
Magnet: Built-in, Mounting: Axial Foot, Bore Size: 32mm, Stroke: 250mm, Cushion: Air Cushion, Rod Boot: None, Lock Style: Lock on Both Sides Non-locking, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -
Magnet: Built-in, Mounting: Axial Foot, Bore Size: 32mm, Stroke: 25mm, Cushion: Air Cushion, Rod Boot: None, Lock Style: Lock on Both Sides Non-locking, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -
Magnet: Built-in, Mounting: Axial Foot, Bore Size: 32mm, Stroke: 200mm, Cushion: Air Cushion, Rod Boot: None, Lock Style: Lock on Both Sides Non-locking, Auto Switch: -, Lead Wire or Prewired Connector: -, Number: -, Auto Switch Mounting Bracket: -
Table 8-1 Quality criteria for clean water (tap water) Standard value Item Unit For circulating fluid For facility water pH (at 25oC) 6.0 to 8.0 6.5 to 8.2 Electric conductance (at 25oC) [S/cm] 100 to 300 100 to 800 Chloride ion [mg/L] 50 or less 200 or less Sulfuric acid ion [mg/L] 50 or less 200 or less Standard item Acid consumption (at pH 4.8) [mg/L] 50 or less 100 or less Total hardness