Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: A93V,
Magnet: Built-in, Mounting: Flange, Bore Size: Ø10 mm, Stroke: 15 mm, Rod End Thread: Without Thread, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire or Prewired Connector: 3m, Number: 1 pc., Option: -
Magnet: Built-in, Mounting: Flange, Bore Size: Ø10 mm, Stroke: 15 mm, Rod End Thread: Without Thread, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, 0.5M, Lead Wire or Prewired Connector: -, Number: -, Option: -
Magnet: Built-in, Mounting: Flange, Bore Size: Ø10 mm, Stroke: 15 mm, Rod End Thread: Without Thread, Auto Switch: M9NV--Solid State, Gen. Purpose, 3 Wire NPN, Vertical, 0.5M, Lead Wire or Prewired Connector: 0.5m Cord Length, M8-3 Pin Connector, Number: -, Option: -
Magnet: Built-in, Mounting: Flange, Bore Size: Ø10 mm, Stroke: 15 mm, Rod End Thread: Without Thread, Auto Switch: M9PV--Solid State, Gen. Purpose, 3 Wire PNP, Vertical, 0.5M, Lead Wire or Prewired Connector: 3m, Number: -, Option: -
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: A93V,
Magnet: D (Built-in), Mounting: F (Flange), Bore Size: Ø10 mm, Stroke: 15 mm, Rod End Thread: B (Without Thread), Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, 0.5M, Lead Wire or Prewired Connector: L (3m), Number: S (1 pc.)
Magnet: D (Built-in), Mounting: F (Flange), Bore Size: Ø10 mm, Stroke: 15 mm, Rod End Thread: B (Without Thread), Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, 0.5M
Magnet: D (Built-in), Mounting: F (Flange), Bore Size: Ø10 mm, Stroke: 15 mm, Rod End Thread: B (Without Thread), Auto Switch: M9NV--Solid State, Gen. Purpose, 3 Wire NPN, Vertical, 0.5M, Lead Wire or Prewired Connector: SAPC (0.5m Cord Length, M8-3 Pin Connector)
Magnet: D (Built-in), Mounting: F (Flange), Bore Size: Ø10 mm, Stroke: 15 mm, Rod End Thread: B (Without Thread), Auto Switch: M9PV--Solid State, Gen. Purpose, 3 Wire PNP, Vertical, 0.5M, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Mounting: F (Flange), Bore Size: Ø10 mm, Stroke: 15 mm, Rod End Thread: B (Without Thread), Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, 0.5M, Lead Wire or Prewired Connector: L (3m)
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: Without
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: Without
Magnet: D (Built-in), Mounting: F (Flange), Bore Size: Ø10 mm, Stroke: 15 mm
Magnet: Built-in, Mounting: Flange, Bore Size: Ø10 mm, Stroke: 10 mm, Rod End Thread: With Thread, Auto Switch: A90--Reed, DC Volt >5<24, AC Volt <100, LED, 2 Wire, 0.5M, Lead Wire or Prewired Connector: 3m, Number: -, Option: -
Magnet: Built-in, Mounting: Flange, Bore Size: Ø10 mm, Stroke: 30 mm, Rod End Thread: With Thread, Auto Switch: A90--Reed, DC Volt >5<24, AC Volt <100, LED, 2 Wire, 0.5M, Lead Wire or Prewired Connector: 3m, Number: -, Option: -
Magnet: D (Built-in), Mounting: F (Flange), Bore Size: Ø10 mm, Stroke: 10 mm, Rod End Thread: With Thread, Auto Switch: A90--Reed, DC Volt >5<24, AC Volt <100, LED, 2 Wire, 0.5M, Lead Wire or Prewired Connector: L (3m)
Magnet: D (Built-in), Mounting: F (Flange), Bore Size: Ø10 mm, Stroke: 30 mm, Rod End Thread: With Thread, Auto Switch: A90--Reed, DC Volt >5<24, AC Volt <100, LED, 2 Wire, 0.5M, Lead Wire or Prewired Connector: L (3m)
Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Port thread type: M5 × 0.8, Auto Switches: A90L
(Or None in the Case of No Switch), Lock Unit Built-in Magnet: D (Built-in), Lock Unit Switch Type: A90L--Reed, AC Volt, Horizontal, 3M