SMC Corporation of America
Elite Part Number Search
Search Results "CDLSF180TN-1000-A90-DA90"

Support brackets are not for mounting; use them solely for providing support. (1400) (1400) (1400) (1400) (1400) (1400) MY1CW40 MY1CW40 MY1CW40 50 50 MY1MW32 MY1MW32 MY1MW32 MY1CW32 MY1CW32 (1100) (1100) (1100) (1100) 40 40 (1200) (1200) (1200) (1200) (1200) (1200) MY1MW25 MY1MW25 MY1MW25 MY1CW25 MY1CW25 MY1CW25 30 (1000) (1000) (1000) (1000) 30 MY1MW20 MY1MW20 MY1MW20 (1000) (900) (1000)

Support brackets are not for mounting; use them solely for providing support. (1400) (1400) (1400) (1400) (1400) (1400) MY1CW40 MY1CW40 MY1CW40 50 50 MY1MW32 MY1MW32 MY1MW32 MY1CW32 MY1CW32 (1100) (1100) (1100) (1100) 40 40 (1200) (1200) (1200) (1200) (1200) (1200) MY1MW25 MY1MW25 MY1MW25 MY1CW25 MY1CW25 MY1CW25 30 (1000) (1000) (1000) (1000) 30 MY1MW20 MY1MW20 MY1MW20 (1000) (900) (1000)

/s Piston speed mm/s 4 Series MY2 Maximum Allowable Moment/Maximum Load Weight Moment/MY2H (Single axis) MY2H/M3 MY2H/M1 MY2H/M2 50 60 50 60 50 60 30 30 30 20 20 20 Moment Nm Moment Nm Moment Nm MY2H40 MY2H40 10 10 10 MY2H40 MY2H25 MY2H25 MY2H25 5 5 5 4 4 4 3 3 3 2 2 2 MY2H16 MY2H16 MY2H16 1 1 1 100 200 300 400500 1000 1500 100 200 300 400500 1000 1500 100 200 300 400500 1000 1500 Piston

1000 1500 Minimum Operating Pressure 100, 150, 200, 250, 300, 350 400, 450, 500, 600, 700, 800 25 1200 1500 32 1500 2000 0.2 100, 150, 200, 250, 300, 350 400, 450, 500, 600, 700, 800 900, 1000 Minimum operating pressure (MPa) 0.16 0.16 40 1500 2000 0.14 0.15 0.12 0.15 Note 1) Contact SMC if the maximum stroke will be exceeded.

L1 L2+A5 L3 2 1 W V 2 E= ( ) 2 9.8 1000 Collision speed V=1.4 Va *) Corrected coeficient 1 420 E= 1( ) =0.088 2 1000 V=1.4 X 300=420 Calculate kinetic energy E (J) of work. Calculate allwable kinetic energy Ea (J). Check that kinetic energy of work does not exceed allowable kinetic energy.

Examine for My My=10(10+30)/1000=0.4 A3=30 Examine for My My=10(30+10)/1000=0.4 A6=10 M=W(Ln+An)/1000 Corrected value for center position distance of moment An: Table 3 Calculate allowable static moment Ma(Nm) Ma=K Mmax Work mounting coeficient K: Fig.3 Allowable moment coeficient : Graph 2 Max. allowable moment Mmax: Table 4 2=M/Ma May=1 x 1 x 15.9=15.9 Mymax=15.9 K=1 =1 2=0.4/15.9=0.0252

(V), D-A93(V), D-A96(V) Specifications D-A96 D-A90 In-line D-A90V D-A93 In-line D-A93V In-line D-A96V Auto switch part no.

1500 0 500 1000 1500 Flow rate L/min (ANR) Flow rate L/min (ANR) AR40-A Rc1/2 AR40-06-A Rc3/4 0.6 0.6 0.5 0.5 Outlet pressure (MPa) Outlet pressure (MPa) 0.4 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0 0 1000 2000 3000 4000 0 0 1000 2000 3000 Flow rate L/min (ANR) Flow rate L/min (ANR) 183 Regulator Series AR10-A to AR40-A Pressure Characteristics (Representative values) Conditions: Inlet pressure 0.7

800 Up to 800 Up to 1000 Up to 1000 Up to 1000 Up to 1000 Up to 1000 37 44 50 56 66 8-25-11 11 Series MGZ With Mounting Bracket Transaxial foot style: (L) 4-LD through LT LH LY X/2 ZZ + Stroke LS + Stroke X X Y LZ LX (mm) Stroke range Bore size (mm) LS ZZ LD Y X LH LT LX LY LZ Up to 800 Up to 800 Up to 1000 Up to 1000 Up to 1000 Up to 1000 Up to 1000 20 25 32 40 50 63 80 86 107 120 138 148

mass m [kg] 32 32 [Example] 50 50 40 40 32 32 10 10 1 100 500 1000 1 100 500 1000 400 300 200 400 300 200 Maximum speed V [mm/s] Maximum speed V [mm/s] Graph m Graph v 0.5 MPa P 0.5 MPa P 1000 1000 80 80 100 100 63 63 50 50 40 40 80 80 100 100 63 63 50 50 40 40 100 100 32 32 Load mass m [kg] Load mass m [kg] 50 50 32 32 10 10 1 100 500 1000 1 100 500 1000 400 300 200 400 300 200 Maximum

-X -XC57 With floating joint 20 1000 1500 100, 150, 200, 250, 300, 350 400, 450, 500, 600, 700, 800 2025 1200 1500 Minimum Operating Pressure 32 1500 2000 Data 100, 150, 200, 250, 300, 350 400, 450, 500, 600, 700, 800 900, 1000 0.2 Minimum operating pressure (MPa) 40 1500 2000 0.16 0.16 0.14 0.15 0.12 0.15 Note 1) Please contact SMC if the maximum stroke will be exceeded.

110 100 120 140 63.5 75.5 88 to 1000 to 1000 to 1000 Front flange type (F) 4FD FY B FT FX (mm) FZ Stroke range Bore size (mm) B FT FD FX FY FZ 40 50 63 74 78 100 9 9 12 12 16 16 80 100 112 58 61 75 100 125 138 to 1000 to 1000 to 1000 Rear flange type (G) 4FD FY B FT FX ZZ + Stroke FZ (mm) Stroke range Bore size (mm) B FT FD FX FY FZ ZZ 40 50 63 74 78 100 9 9 12 12 16 16 80 100 112 58 61

75 133 368 Up to 1000 98 345 345 388.5 452 477 368 368 409.5 470 495 8 9 0.2 stroke 98 345 30 to 1000 75 133 368 98 Up to 1000 0.2 stroke 106 388.5 75 141 409.5 106 30 to 1200 Up to 1200 0.2 stroke 111 448 85 153 466 115 30 to 1200 Up to 1200 0.2 stroke 111 468 90 153 486 120 30 to 1200 Up to 998 0.2 stroke 141 579.5 105 176 595.5 30 to 1200 0.17 stroke 9-9-12 13 Series CLS Cylinder with

1500 100 200 300 400500 1000 1500 100 200 300 400500 1000 1500 Piston speed mm/s Piston speed mm/s Piston speed mm/s Load Weight/MY2C MY2C/m1 MY2C/m2 MY2C/m3 60 60 60 50 50 50 30 30 30 20 20 20 Load weight Nm Load weight Nm Load weight Nm MY2C40 MY2C40 MY2C40 10 10 10 MY2C25 MY2C25 MY2C25 5 5 5 4 4 4 MY2C16 MY2C16 3 3 3 MY2C16 2 2 2 1 1 1 100 200 300 400500 1000 1500 100 200 300 400500 1000

1000 80 80 100 100 63 63 50 50 40 40 80 80 100 100 100 100 Double Acting, Single Rod Double Acting, Double Rod Lock Unit Made to Order Auto Switch Load mass m [kg] Load mass m [kg] 63 63 50 50 40 40 50 50 32 32 32 32 10 10 1 100 500 400 300 200 1000 1 100 500 1000 400 300 200 Maximum speed V [mm/s] Maximum speed V [mm/s] Graph n Graph c 0.4 MPa P < 0.5 MPa 0.4 MPa P < 0.5 MPa 1000 1000

50 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 6000 63 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 Made to Order Specifications (For details, refer to page 10-21-1.)

50 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 6000 63 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 Made to Order Specifications (For details, refer to page 10-21-1.)

M9NW Relay PLC Yes 3-wire (NPN) F59W Diagnostic indication (2-color indicator) 5 V, 12 V IC circuit M9PW 3-wire (PNP) F5PW M9BW 24 V 2-wire 12 V Grommet J59W M9NA1 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V M9PA1 Water resistant (2-color indicator) M9BA1 2-wire 12 V F5BA1 F59F 4-wire (NPN) IC circuit IC circuit IC circuit 5 V, 12 V Diagnostic output (2-color indicator) A96 A93 A90