SMC Corporation of America
Elite Part Number Search
Search Results "CDNA2D40-350-D-M9B"

10 2 10 15 20 CXT 32 40 5 15 10 5 1 10 10 20 (mm) D-F7W D-J79W D-F7BAL D-F7NT D-F79F Auto switch model D-A7 D-A8 D-A73C D-A80C D-A7H D-A80H D-F7 D-J79 D-F7V D-J79C D-F7WV D-F7BAVL D-A79W Application No. of auto switches mounted 2 5 10 15 15 20 20 CXT 32 40 1 5 5 10 15 15 20 Other than the applicable auto switches listed in How to Order, the following auto switches can be mounted.

(Make sure that there is no rotation backlash in the table.) 3 Tighten both adjustment bolts c and d to approx. 45. Note 1) Tighten both adjustment bolts c and d to approx. 45. Note 1) 4 Lock adjustment bolts c and d with fixing nuts. Note 2) Lock adjustment bolts c and d with fixing nuts.

BQ-1 BQ-2 BQ2-012 Weight (g) 1.5 1.5 5 259 CHQB/CHQWB Series How to Mount and Move the Auto Switch Solid state D-M9N(V), D-M9P(V), D-M9B(V) D-M9NW(V), D-M9PW(V), D-M9BW(V) D-M9NA(V), D-M9PA(V), D-M9BA(V) Reed D-A90(V), A93(V), A96(V) 20 1.

, D-F9WV D-A9V D-M9, D-F9W D-M9V No. of auto switches mounted 2 pcs. 15 Note) 10 10 5 MK(2) 10 Note) 15 Note) 1 pc. 5 5 Note) Please consult with SMC for shorter stroke length than indicated in the table.

, D-F9WV D-A9V D-M9, D-F9W D-M9V No. of auto switches mounted 2 pcs. 15 Note) 10 10 5 MK(2) 10 Note) 15 Note) 1 pc. 5 5 Note) Please consult with SMC for shorter stroke length than indicated in the table.

-X 663 CE1 Series Auto Switch Mounting Auto Switch Proper Mounting Position (Detection at Stroke End) and Its Mounting Height D-A9V D-M9V D-M9WV D-M9AV D-A9 D-M9 D-M9W D-M9A 12 to 20 25 U B A 32 to 63 D-A9 D-M9 D-M9W D-M9A D-A9V D-M9V D-M9WV D-M9AV U D-A7 D-A80 D-A7H D-A80H D-F7 D-J79 D-F7W D-J79W D-F79F D-F7NT D-F7BA D-A73C D-A80C D-J79C D-A79W D-F7WV D-J7V D-F7BAV 12 to 20 U B A 32 to 63

. 10-12-25 25 Series CE1 Proper Auto Switch Mounting Position (Detection at stroke end) Auto switch A B Proper Auto Switch Mounting Position D-A7H/A80H D-A73C/A80C D-F7/J79 D-F7V/J79C D-F7W/J79W D-F7WV D-F7BAL D-F7BAVL/F79F Auto switch model D-A79W D-F7NTL D-A7 D-A80 D-M9 D-M9V D-F9W D-F9WV D-A9 D-A9V D-F9BAL Bore size (mm) A B A B A B A B A B A B A B 12 40.5 4 41 4.5 38 2 46 9.5 39.5 3 43.5

. 10-12-25 25 Series CE1 Proper Auto Switch Mounting Position (Detection at stroke end) Auto switch A B Proper Auto Switch Mounting Position D-A7H/A80H D-A73C/A80C D-F7/J79 D-F7V/J79C D-F7W/J79W D-F7WV D-F7BAL D-F7BAVL/F79F Auto switch model D-A79W D-F7NTL D-A7 D-A80 D-M9 D-M9V D-F9W D-F9WV D-A9 D-A9V D-F9BAL Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080

Protrusion of Auto switch Lead wire type In-line entry Perpendicular entry Illustration MHZ Auto switch Hysteresis L L Auto switch operating position (ON) Finger position MHF Auto switch operating position (OFF) MHL D-M9 D-F9W D-M9V D-F9WV Model MHR Open Close Open Close Open Close Open Close Open Close Open Close Open Close Open Close Open Close Open Close Open Close Open Close 4.5 4.5 4.5

Protrusion of Auto switch Lead wire type In-line entry Perpendicular entry Illustration MHZ Auto switch Hysteresis L L Auto switch operating position (ON) Finger position MHF Auto switch operating position (OFF) MHL D-M9 D-F9W D-M9V D-F9WV Model MHR Open Close Open Close Open Close Open Close Open Close Open Close Open Close Open Close Open Close Open Close Open Close Open Close 4.5 4.5 4.5

30 25 20 15 10 5 D-A9 x x x (2) 2 pcs. on same side Standard piping type(1) D-M9, D-F9W x x (2) D-A9V x x x D-A9 (2) x 1 pc. each on 2 sides D-M9, D-F9W (2) 2-port size D-A9V x D-A9 (2) x x x 2 pcs. on same side Axial piping type D-M9, D-F9W (2) x x D-A9V x x x D-M9V, D-F9WV x x D-F8 D-A9 x (2) 1 pc. each on 2 sides D-M9, D-F9W (2) D-M9V x 2-port size D-M9V, D-F9WV D-F8 Note 1) With the

Contact SMC regarding the specifications for psi unit and F. 229 Filter Regulator with Built-in Pressure Gauge with Backflow Function AWG20K/30K/40K Construction AWG20K AWG30K/40K B D P A A K U C C C S O P H L to K U C S O H L to B D D-D C-C A-A B-B !0 o !1 !0 o !1 y y !2 !

30 d (D) (C) (D) (C) H B H B Part no.

Note 5) Dimensions other than those marked (LA) are the same as the basic type (no locking type). 598 RS2H Series Auto Switch Mounting 1 Auto Switch Proper Mounting Position (Detection at Stroke End) D-M9 D-M9W D-M9AV D-M9V D-M9WV D-M9A D-A9 D-A9V A B Auto switch Auto Switch Proper Mounting Position (mm) Auto switch model D-M9 D-M9W D-M9AV D-M9V D-M9WV D-M9A D-A9 D-A9V A 9.0 B 23.5 A 11.0

Technical Data 1219 MY1H Series Auto Switch Mounting Auto Switch Proper Mounting Position Auto Switch Proper Mounting Position (mm) D-M9 D-M9V D-M9W D-M9WV D-M9AL D-M9AV Auto switch model D-A9 D-A9V A A Bore size A A 25 32 40 81 85 112.5 116.5 133.5 137.5 Note) Adjust the auto switch after confirming the operating conditions in the actual setting.

D-M9V, D-M9WV D-M9A D-M9AV A B W A B W A B W A B W 12 6.2 6.2 3.8 6.2 6.2 1.8 6.2 6.2 5.8 6.2 6.2 3.8 16 6.7 6.7 3.3 6.7 6.7 1.3 6.7 6.7 5.3 6.7 6.7 3.3 20 7.5 10 7.5 10 7.5 10 2 7.5 10 25 8 12 8 12 8 12 8 12 Auto Switch Mounting Height U [mm] Auto switch model Bore size D-M9V, D-M9WV, D-M9AV U 12 19.5 16 21 20 23 25 24.5 W A B A Operating Range [mm] Auto switch model Applicable

Magnet: D (Built-in), Mounting: B (Through Hole), Overall Length: Standard, Bore Size: 300 (3"), Stroke: 350 (3 1/2"), Body Option: M (Male Rod End), Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)