Band Mount: None, Rail Mount: None, Tie-rod Mount: None, Direct Mount: A93V--Reed, 24VDC max, 100VAC max, LED, Vertical, Lead Wire: Z (5m)
Sensor Type: Contacting, Output Format: N/A, Wiring Method: 2-Wire, Type: Main Body, Lead wire length(m): 5, Applicable load: Relay / PLC
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, Series Catalog, CYL, COMPACT, PLATE, ACTUATOR, MU COMPACT CYLINDER, IE, 25MM MU DBL-ACT AUTO-SW, .00000 lb
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 1.0, Specification: Built-in magnet, Support bracket: Without mounting bolt, Port thread type: Rc, Auto
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 320, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: No, Operating Pressure(MPa): 0.05~1, Auto Switches: A93V, Lead Wire Length(m): 5, The number of the switches: 2, Type of
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: Rubber cushion, Specification: Built-in magnet, Port thread type: Rc, Auto
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): -, Cushion: Rubber bumper at both ends, Port thread type: NPT,
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): -, Cushion: Rubber bumper at both ends, Port thread type: Rc,
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): -, Cushion: Rubber bumper at both ends, Port thread type: Rc,
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber bumper at both ends, Operating Pressure(MPa): 0.1 to 1.0, Specification: Built-in magnet, Support bracket: Through-hole
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Magnet: D (Built-in), Mounting: B (Through Hole, Standard), Bore Size: 32mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 20mm, Action: B (Double Acting/Spring Loaded), Rod End: Round Bar Style, Direct Mount Switch Groove: Z (Direct Mount Switch Groove), Mounting Bolt: None, Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired
Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: 50mm, Water Resistant: None, Port Thread: Bore 12, 16: M Thread; Bore 20 to 50: Rc, Stroke: 30mm, Action: D (Double Acting), Rod End: Round Bar Style, Direct Mount Switch Groove: Z (Direct Mount Switch Groove), Mounting Bolt: None, Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: Z (
Magnet: D (Built-in), Mounting: A (Both Ends Tapped), Bore Size: 40mm, Water Resistant: None, Port Thread: TN (NPT), Stroke: 20mm, Action: D (Double Acting), Rod End: G (Chamfered w/Female Rod End), Direct Mount Switch Groove: Z (Direct Mount Switch Groove), Mounting Bolt: None, Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: Z (5m)
Magnet: D (Built-in), Bore Size: 40mm, Port Thread: Screw-in Piping, Stroke: 30mm, Action: T (Single Acting/Spring Extend), Rod End Configuration: R (Roller Style), Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: Z (5m)
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): 0.07~1, Cushion: None, Specification: Built-in magnet, Support bracket:
Magnet: D (Built-in), Mounting: B (Through Hole, Both Ends Tapped), Bore Size: 20mm, Stroke: 25mm, Body Option: Standard, Bumper/Rod End Thread: C (Rubber Bumper), Auto Switch: A93V--Reed, DC Volt, AC Volt, LED, Vertical, Lead Wire or Prewired Connector: Z (5m)