Magnet: Built-in, Mounting: Through Hole, Both Ends Tapped, Bore Size: 12mm, Stroke: 30mm, Option: Standard (Rod End Female Thread), Auto Switch: A90--Reed, AC Volt, Horizontal, 0.5m, Lead Wire or Prewired Connector: -, Number: -, Thread: -

Magnet: Built-in, Mounting: Through Hole, Both Ends Tapped, Bore Size: 12mm, Stroke: 75mm, Option: Rubber Bumper,Rod End Male Thread, Auto Switch: A90--Reed, AC Volt, Horizontal, 0.5m, Lead Wire or Prewired Connector: -, Number: -, Thread: -

Magnet: Built-in, Mounting: Through Hole, Both Ends Tapped, Bore Size: 12mm, Stroke: 10mm, Option: Rubber Bumper, Auto Switch: A90--Reed, AC Volt, Horizontal, 0.5m, Lead Wire or Prewired Connector: -, Number: -, Thread: -

Inner Diameter(φ): 25, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: A90

Magnet: D (Built-in), Mounting: B (Through Hole, Both Ends Tapped), Bore Size: 25mm, Stroke: 100mm, Option: CM (Rubber Bumper,Rod End Male Thread), Auto Switch: A90--Reed, AC Volt, Horizontal, 0.5m

Magnet: D (Built-in), Mounting: B (Through Hole, Both Ends Tapped), Bore Size: 16mm, Stroke: 100mm, Option: CM (Rubber Bumper,Rod End Male Thread), Auto Switch: A90--Reed, AC Volt, Horizontal, 0.5m

Inner Diameter(φ): 25, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Auto Switches: A90

Magnet: Built-in, Mounting: Through Hole, Both Ends Tapped, Bore Size: 16mm, Stroke: 100mm, Option: Rubber Bumper,Rod End Male Thread, Auto Switch: A90--Reed, AC Volt, Horizontal, 0.5m, Lead Wire or Prewired Connector: -, Number: -, Thread: -

Clean Series: 10 (Relief Type), Magnet: D (Built-in), Bore Size: 12mm, Stroke: 30mm, Rod End Thread: M (Male), Auto Switch: A90--Reed, AC Volt, Horizontal

Clean Series: Relief Type, Magnet: Built-in, Bore Size: 12mm, Stroke: 30mm, Rod End Thread: Male, Auto Switch: A90--Reed, AC Volt, Horizontal, Lead Wire or Prewired Connector: -, Number: -

Magnet: D (Built-in), Mounting: D (Double Clevis), Bore Size: Ø25 mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 100mm, Body Option: CM (Rubber Bumper, Rod End Male Thread), Lock Position: H (Rear Locking), Release of Manual: N (Non-locking Type), Auto Switch: A90--Reed, AC Volt, Horizontal

Magnet: Built-in, Mounting: Double Clevis, Bore Size: Ø25 mm, Port Thread Type: Rc: 32-100 Bore; M Thread 12 to 25 Bore, Stroke: 100mm, Body Option: Rubber Bumper, Rod End Male Thread, Lock Position: Rear Locking, Release of Manual: Non-locking Type, Auto Switch: A90--Reed, AC Volt, Horizontal, Lead Wire or Prewired Connector: -, Number: -

A90V A90 V V IC circuit Relay, PLC 24 V 12 V 2-wire Yes C73C A73C V V V V Connector No 24 V or less C80C A80C V V V V IC circuit Diagnostic indication (2-color indication) Grommet Yes A79W V V Water resistant type auto switches can be mounted on the above models, but in such case SMC cannot guarantee water resistance.

Symbol Nil A B C D-M9N(M)(L)(Z) D-M9P(M)(L)(Z) D-M9B(M)(L)(Z) D-A90(L) D-A93(M)(L)(Z) M9N(M)(L)(Z) M9P(M)(L)(Z) M9B(M)(L)(Z) A90(L) A93(M)(L)(Z) M9// Solid state auto switch Reed auto switch (Not applicable to flange size 16) Without auto switch (with built-in magnet) Standard lead wire length is 0.5 m.

The CQS compact cylinder is available for those small bore cylinder applications where saving space is a concern. The CQS offers standard long strokes * in four bore sizes from 12 to 25mm. Long stroke versions incorporate a wear band and thicker piston to handle the increased bearing needs of the longer strokes. Both switch capable and non-switch capable body styles are the same, and switches

The CQS compact cylinder is available for those small bore cylinder applications where saving space is a concern. The CQS offers standard long strokes * in four bore sizes from 12 to 25mm. Long stroke versions incorporate a wear band and thicker piston to handle the increased bearing needs of the longer strokes. Both switch capable and non-switch capable body styles are the same, and switches

The CQS compact cylinder is available for those small bore cylinder applications where saving space is a concern. The CQS offers standard long strokes * in four bore sizes from 12 to 25mm. Long stroke versions incorporate a wear band and thicker piston to handle the increased bearing needs of the longer strokes. Both switch capable and non-switch capable body styles are the same, and switches

The CQS compact cylinder is available for those small bore cylinder applications where saving space is a concern. The CQS offers standard long strokes * in four bore sizes from 12 to 25mm. Long stroke versions incorporate a wear band and thicker piston to handle the increased bearing needs of the longer strokes. Both switch capable and non-switch capable body styles are the same, and switches

Symbol Nil A B C D-M9N(M)(L)(Z) D-M9P(M)(L)(Z) D-M9B(M)(L)(Z) D-A90(L) D-A93(M)(L)(Z) M9N(M)(L)(Z) M9P(M)(L)(Z) M9B(M)(L)(Z) A90(L) A93(M)(L)(Z) M9// Solid state auto switch Reed auto switch (Not applicable to flange size 16) Without auto switch (with built-in magnet) Standard lead wire length is 0.5 m.