C 8 8 8.5 8.5 D 50 60 50 60 75 85 75 85 85 95 75 85 95 130 100 130 Mounting bolt M3 X 50l M3 X 60l M3 X 50l M3 X 60l M5 X 75l M5 X 85l M5 X 75l M5 X 85l M5 X 85l M5 X 95l M5 X 75l M5 X 85l M6 X 95l M6 X 130l M8 X 100l M8 X 130l MKB12-10 MKB12-20 MKB16-10 MKB16-20 MKB20-10 MKB20-20 MKB25-10 MKB25-20 MKB32-10 MKB32-20 MKB40-10 MKB40-20 MKB50-20 MKB50-50 MKB63-20 MKB63-50 PTo attach and detach
Example) Bolt M5 x 50l 4pcs.
Mounting: Direct Mount Rod Side Tapped, Bore Size: 12mm equiv., Stroke: 50mm, Connector: w/Connector, Sensor Cable Length: 3m, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Lead Wire or Prewired Connector: -, Number: -
Bore Size: 20mm, Port Thread: Rc (25-100 Bore, M Thread 16-20 Bore), Piping: Standard, Stroke: 50mm, Stroke Adjusting Unit: L (Low Load Shock Absorber+Adjust Bolt), End Lock: None, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal
Mounting: B (Through Hole Both Ends Tapped Common), Bore Size: 50 mm, Cylinder Port: TN (NPT), Stroke: 50 mm, Rotation: L (Left Rotation), Body Option: Standard (Female Thread), Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire
Mounting: B (Through Hole Both Ends Tapped Common), Bore Size: 50 mm, Cylinder Port: M Thread: 20, 25 Bore; Rc: 32 to 63 Bore, Stroke: 50 mm, Rotation: L (Left Rotation), Body Option: Standard (Female Thread), Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire
Mounting: B (Direct Mount Rod Side Tapped), Bore Size: 12mm equiv., Stroke: 50mm, Connector: w/Connector, Sensor Cable Length: L (3m), Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire
Mounting: Through Hole Both Ends Tapped Common, Bore Size: 50 mm, Cylinder Port: NPT, Stroke: 50 mm, Rotation: Left Rotation, Body Option: Standard (Female Thread), Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Lead Wire or Prewired Connector: -, Number: -, X Option: -
Mounting: Through Hole Both Ends Tapped Common, Bore Size: 50 mm, Cylinder Port: M Thread: 20, 25 Bore; Rc: 32 to 63 Bore, Stroke: 50 mm, Rotation: Left Rotation, Body Option: Standard (Female Thread), Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Lead Wire or Prewired Connector: -, Number: -, X Option: -
Aluminum Alloy, Rodless Cylinder Joint Type: Mechanically Jointed, Guide: [Rolling Guide] Linear guide type, Table Size Width W(mm): 78, Table Size Height H(mm): 46, Table Surface Treatment: [Anodize] Hard Anodize, Environment: General Purpose, Maximum Load(kg): 17.6, Piping Format: Standard type, Port Screw Type: M screw, Cushion: Air cushion, Specification: Magnet built-in, Auto Switches: M9BW
Mounting: B (Tapped on Both Sides), Bore Size: 32mm, Stroke: 50mm, Cushion: 40~63 Bore-Cushion Both Sides; 12~32 Bore-No Cushion, Connector: Connector, Cable Length: L (3m), Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire
. *3 Position after returning to origin *4 [ ] for when the direction of return to origin has changed Dimensions [mm] Model L A B n D E F Without lock With lock LEFS25El-50l 285.5 330.5 56 160 4 20 LEFS25El-100l 335.5 380.5 106 210 4 LEFS25El-150l 385.5 430.5 156 260 4 LEFS25El-200l 435.5 480.5 206 310 6 2 240 LEFS25El-250l 485.5 530.5 256 360 6 2 240 LEFS25El-300l 535.5 580.5 306 410
The lock is released by screwing in the manual release bolt until the white mark of the lock monitor on the top of the brake cylinder moves to the FREE position. 140 160 180 200 250 Bore size (mm) 125 M6 x 1.0 x 35l M6 x 1.0 x 40l M8 x 1.25 x 40l M10 x 1.5 x 50l M10 x 1.5 x 55l M12 x 1.75 x 70l Manual release bolt Screw depth 30 32 35 40.5 45 55 In the case the manual release bolt is not
Item Display Content Setting of connection product [4L] 4 L range [16L] 16 L range [40L] 40 L range [PFW] is selected [100L] 100 L range [250L] 250 L range [10L] 10 L range [rAnG] [50L] 50 L range Selection of flow range [100L] 100 L range [PFA] is selected [200L] 200 L range [500L] 500 L range [4L] 4 L range [PFd] is selected [16L] 16 L range [40L] 40 L range Press the SET button to set.
Filter Rc1/2 20m HRS-PF003 3 Flow meter 0 to 50L/min 4 Pressure gauge 0 to 1.0MPa 5 Others (pipe, hose, etc.) 15 or more Y-strainer Rc1/2 #40 Install either the strainer or filter.
Note 1 Valve Rc1/2 To prevent liquid spillage from the customer's piping or overflow from the tank during maintenance work. 2 Filter Rc1/2 20m HRS-PF003 If foreign objects with a size of 20 m or more are likely to enter, install the particle filter. 3 Flow meter 0 to 50L/min 4 Pressure gauge 0 to 1.0MPa 5 Others (pipe, hose, etc.) 15 or more Y-strainer Rc1/2 #1000 Install either the strainer
If foreign objects with a size of 20 m or more are likely to enter, install the particle filter. 2 Filter Rc1/2 20m HRS-PF003 3 Flow meter 0 to 50L/min 4 Pressure gauge 0 to 1.0MPa 5 Others (pipe, hose, etc.) 15 or more Y-strainer Rc1/2 #1000 Install either the strainer or filter.
Filter Rc1/2 20m HRS-PF003 or HRS-PF004 3 Flow meter 0 to 50L/min 4 Pressure gauge 0 to 1.0MPa 5 Others (pipe, hose, etc.) 15 or more Y-strainer Rc1/2 #40 Install either the strainer or filter.
Filter Rc1/2 20m HRS-PF003 or HRS-PF004 3 Flow meter 0 to 50L/min 4 Pressure gauge 0 to 1.0MPa 5 Others (pipe, hose, etc.) 15 or more Y-strainer Rc1/2 #40 Install either the strainer or filter.