Response speed: 5ms or less , Proof pressure: 500 kPa , Low flow rate range , Output: 1 to 5V analog (non-linear) , Piping specification: M5 female threads, Weight 10g (not including the lead wire), Flow Sensor for Air, DIGITAL FLOW SWITCH, F29, 10 lb
10ms 5ms Maximum inrush current 0.7A 1.5A 0.7A 1.5A 7A 0.7A 1.5A 7A Maximum power 3W 4W 3W 8W 6W consumption ANALOGUE INPUT CHARACTERISTICS AC INPUT CHARACTERISTICS 10 6 inputs from I01 to I06 Input voltage 100-240 VAC + 10% 15%, 20 8 inputs from I01 to I08 50-60 Hz Measurement range 0-255 Input impedance >or = 800 kOhms Resolution 8 bits 10 000/256mV Pull-in votage at logic state 1 80V
OUT2 setting/(CH1 only) MPa or kPa OUT1 OUT2 CH 1 2 3 4 PRESSURE Normally Open Normally Closed SET SET 8 Series PSE Operation : Initial Setting 4 Response time setting MPa kPa OUT1 OUT2 CH 1 2 3 4 PRESSURE 5ms 20ms 160ms 640ms SET Press SET button.
Primary pressure normal Primary pressure drop Primary pressure increase P1 Set value P2 Time ON Switch output 1, 2 OFF Time [ ] Switch output response time 5ms or more 10ms or less when auto shift is input. Hi Auto shift input Lo 3 types of piping Different piping methods are possible to accommodate the installation location.
For Dry Air, Pilot Operated 2 Port Solenoid Valve Series VQ20/30 Compact & lightweight with large flow capacity Weight (g) Effective area (mm2) 46 9 (Cv0.5) VQ20 VQ30 80 17.5 (Cv1) Series VQ30 VX VNl VQ Series VQ20 High frequency operation possible and long operating life High speed response 5ms or less (VQ20), 20ms or less (VQ30) (Without indicator light and surge voltage suppressor, at
Length 20m 100m Symbol 20 100 Tube I.D.
/100m 20m/100m 20m/100m 20m/100m 20m/100m 20m/100m 20m/100m 20m/100m 20m/100m 20m/100m 20m/100m Min Bending Radius (mm) 15mm 23mm 27mm 31mm 60mm 0.47 0.59 0.91 1.18 1.57 12mm -20~60OC = 4~140F Operating Temperature -20~60OC -20~60OC -20~60OC -20~60OC -20~60OC -20~60OC -20~60OC -20~60OC -20~60OC -20~60OC -20~60OC Material Nylon 12 Nylon 12 Nylon 12 Nylon 12 Nylon 12 Nylon 12 Nylon 12 Nylon
TS0604BU-100X3 Consult SMC in case of 16. 2.4-2 Soft Polyurethane Tubing Series TUS Suitable for piping in confined spaces Extremely flexible Soft Polyurethane Tubing Series Table : 100m roll : 20m roll Model TUS1208 TUS0425 TUS0604 TUS0805 TUS1065 Tube O.D. (mm) 12 4 6 8 10 Tube I.D.
Note 2) Values under the following conditions: Fluid: Water; Filtration: 20m; Pressure drop: 0.02MPa or less.
Equipment Clean Series Tubing Polyurethane Tubing Series10-TU Series P 20m bundle (~6ft) Tubing size Metric size (series TU) 20 TU0425 10 BU 10-TU1208 10-TU1065 10-TU0805 10-TU0604 10-TU0425 O.D. mm Designation 8 10 5 6.5 12 8 2.5 6 4 4 I.D. mm Color Clean series B Black Black White (W) Red (R) Blue (BU) Yellow (Y) Green (G) Clear (C) Orange (YR) W White R Red BU Blue Tubing designation
Equipment Clean Series Tubing Polyurethane Tubing Series10-TU Series P 20m bundle (~6ft) Tubing size Metric size (series TU) 20 TU0425 10 BU 10-TU1208 10-TU1065 10-TU0805 10-TU0604 10-TU0425 O.D. mm Designation 8 10 5 6.5 12 8 2.5 6 4 4 I.D. mm Color Clean series B Black Black White (W) Red (R) Blue (BU) Yellow (Y) Green (G) Clear (C) Orange (YR) W White R Red BU Blue Tubing designation
(TPH0806, TPH1075, TPH1209) -20 0 0 20 40 60 80 Operating temperature C 10 Soft Polyolefin Tubing Series TPS Clean Tubing Series 20m bundle 100m bundle Designation TPS0425 TPS0604 TPS0805 TPS1065 TPS1208 O.D. mm 4 6 8 10 12 I.D. mm 2.5 4 5 6.5 8 White (W) Black (B) Red (R) Blue (BU) Yellow (Y) Green (G) Specifications Air, Nitrogen gas, Water (pure water) Note 1) Fluid Maximum operating
(Example) Load weight 300kg, Transfer speed 20m/min, Friction coefficient = 0.1 RE A B (How to read graph) In graph (2), find the intersection of the vertical axis representing the weight of 300kg and the horizontal axis representing the speed of 20m/min. And select the bore size 63 positioned within the operating range of the cylinder.
The longest transmission distance for Hyrodless Monosashi-kun is 20m, wiring above than the figure, should be taken noted at. 31 9-1-2 Installation of Controller 1. During installation of controller, use M4 bolt and DIN rail. 2. Prevent from direct shining of sun, high or low temperatures environment. [ Operating temperature range : 0~50 ] 3.
B Black W White Hl R Red BU Blue Y Yellow Dl w 20m roll for Inch size (except black and white) Green Clear Orange G C YR wThe value of the max. operating pressure is at a temperature of 20C. Refer to the burst pressure characteristics curve for other temperatures. Avoid abnormal temperature rises which may burst the tubing. MS Suffix -X4 to the end of part number. Ex.)
(Example) Load weight 300kg, Transfer speed 20m/min, Friction coefficient = 0.1 RE A B (How to read graph) In graph (2), find the intersection of the vertical axis representing the weight of 300kg and the horizontal axis representing the speed of 20m/min. And select the bore size 63 positioned within the operating range of the cylinder.
Lock keys ( ref er t o P11) M i ni m um pressure ( F_1) adj ust i ng range M axi m um pressure ( F_2) adj ust i ng range 100% 100% 50% 0% 10% 0% 20m A 20m A 5V 10V 20m A 20m A 5V 10V 4 0 0 0 12 10 2. 5 5 4 0 0 0 12 10 2. 5 5 ( N ot e 1) : F_1 i s adj ust abl e i n a range f rom 0 t o 50% of t he rat ed val ue. ( N ot e 2) : F_2 i s adj ust abl e i n a range f rom 10 t o 100% of t he rat ed
Lock keys ( ref er t o P11) M i ni m um pressure ( F_1) adj ust i ng range M axi m um pressure ( F_2) adj ust i ng range 100% 100% 50% 0% 10% 0% 20m A 20m A 5V 10V 20m A 20m A 5V 10V 4 0 0 0 12 10 2. 5 5 4 0 0 0 12 10 2. 5 5 ( N ot e 1) : F_1 i s adj ust abl e i n a range f rom 0 t o 50% of t he rat ed val ue. ( N ot e 2) : F_2 i s adj ust abl e i n a range f rom 10 t o 100% of t he rat ed
20m 31 9-1-2 M4 DIN [050] [25%85%] 1055Hz0.75mmXYZ 2 9-2 9-2-1 AC100V15AC85VAC115V 50/60Hz DC24V100.4A 0.75mm 2 FG0.75mm 2D 100 FG FG 9-2-2 5m 20m5m CE1-R U 25mm *400 200mm 1 R25 100 / 32 9-3 9-3-1 13 2 AC100V +12V (AC100V15%) 12 COM GND COM SENSOR INPUT FG A B 1 11 F.G 10 24E (24V10%0.4A) COM +24V 4 9 COM 3 8 BR 2 7 B VAL.OUT OUTPUT 1 6 A END INPUT COM 4 5 COM
Tajima Musen Denki Company Max Transmission Distance 20m (6 core twisted pair shielded wire) Position Detection Method Magnetive Scaled Piston Rod & Detection Head (50cm cable.