D-Z7/Z80/Y5/Y6/Y7 types are shipped together, (but not assembled). (But, only the mounting bracket for the above models is assembled when shipping.) Bore size J Nylon tarpaulin Rod boot 125 125 mm K Heat resistant tarpaulin 140 140 mm Nil With cushion in both ends 160 160 mm N Without cushion Cylinder stroke (mm) Refer to Maximum Stroke on page 9-8-9.
The load voltage is 100VAC 12.5 Most sensitive position D-Z76, Z80 Indicator light Type D-Z80 without indicator light Use a contact protection box in any of the above situations, as the life of the contacts may otherwise be reduced. (Refer to page 14 for detailed specifications of the contact protection boxes.)
Standard Strokes Bore size (mm) 20 32 40 50 63 80 100 Standard strokes (mm) 5, 10, 15, 20, 25, 30, 35, 40, 45, 50 Made to Order 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 Page 34 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 JIS symbol 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 10, 15, 20, 25, 30, 35, 40, 45, 50, 75, 100 10, 15, 20, 25, 30
Standard strokes Bore size (mm) Standard stroke (mm) Long stroke (mm) 75, 100, 125, 150, 175 350, 400, 450, 500, 600 40, 50, 63 200, 250, 300 700, 800, 900, 1000 Intermediate strokes and strokes of 75mm or less can also be manufactured.
75 75 75 75 75 136 144 152 152 164 164 41 23 51 25 51 25 56 29 61 29 Standard Type: With Mounting Bracket Dimensions not shown are the same as basic style.
75 75 75 75 75 136 144 152 152 164 164 41 23 51 25 51 25 56 29 61 29 Standard Type: With Mounting Bracket Dimensions not shown are the same as basic style.
(variations on the order of 30%) A B Auto switch model D-Y5 D-Y6 D-Y7P D-Y7PV D-Y5 D-Y6 D-Y7P D-Y7PV D-Y7W D-Y7WV D-Z7 D-Z80 D-Z7 D-Z80 D-Y7W D-Y7WV Cylinder model REBH15 72 72 122 72 122 122 REBH25 86 86 164 86 164 164 REBHT25 86 86 164 86 164 164 REBHT32 82 82 183 82 183 183 Auto Switch Mounting When mounting auto switches, they should be inserted into the cylinder's switch groove from
CV () Dimensions DC () Blue MVGQ D-Z73 D-Z76, Z80 D-Z80 CC Indicator light Switch mounting screw Switch mounting screw D-Z80 without indicator light Slotted set screw (M2.5 x 4L) RB 30.5 27.6 2.3 2.5 OUT() Brown Contact protection box CD-P11 CD-P12 Slotted set screw (M2.5 x 4L) Reed switch J 6.2 6.2 OUT ( ) Blue Indicator light DNote 1) Operating load is an induction load.
D-Z7/ Z80 6 9 CY1HT D-Y5/ Y6/ Y7 5 6 Some auto switches cannot be mounted. Since this is a guideline including hysteresis, not meant to be guaranteed.
Cylinder bore size/Standard stroke (mm) 40 30, 50, 75, 100 63 30, 50, 75, 100 100 30, 50, 75, 100 Applicable auto switches /Refer to page 5.3-2 of "Best Pneumatics No. 2" for auto switch related information.
, 100, 125, 150, 175, 200, 250, 300, 350 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350 50, 75, 100, 125, 150, 175, 200, 250, 300, 350 RLQ Manufacture of Intermediate Stroke MLU ML1C Spacer installation type Spacers are installed in the standard stroke cylinders. 20 to 32: Stroke can be modified by the 1 mm interval. 40 to 100: Stroke can be modified by the 5 mm interval.
, 100, 125, 150, 175, 200, 250, 300, 350 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350 50, 75, 100, 125, 150, 175, 200, 250, 300, 350 RLQ Manufacture of Intermediate Stroke MLU ML1C Spacer installation type Spacers are installed in the standard stroke cylinders. 20 to 32: Stroke can be modified by the 1 mm interval. 40 to 100: Stroke can be modified by the 5 mm interval.
MGQ 12, 16 M L 10, 20, 30, 40, 50, 75, 100 2020, 30, 40, 50, 75, 100 125, 150, 175, 200 Data MGQ 20, 25 M L M L MGQ 32, 40 50, 63 80, 100 25, 50, 75, 100, 125 150, 175, 200 OUT (N) IN (N) Theoretical Output (N) Bore size (mm) Operating pressure (MPa) Rod size (mm) Operating direction Piston area (mm2) 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Made to Order Specifications (For details, refer to
(Except 10, 16, 20) (Refer to Tightening Torgue for Stroke Adjusting Unit Holding Bolts.) 8-11-75 72 Series MY1H Precautions With End Locks Recommended Pneumatic Circuit Relation to Cushion Caution Caution This is necessary for the correct locking and unlocking actions. 1.
Applicable Auto Switch Model Refer to p.5.3-2 to 5.3-75 for the detailed specifications of auto switches.
Mounting bolt Mounting bolt C' D' 45 50 55 60 65 70 50 55 60 65 70 75 55 60 65 70 75 80 85 90 95 100 55 60 65 70 75 80 85 90 95 100 55 60 65 70 75 80 85 90 95 100 125 150 D 40 45 50 55 60 65 45 50 55 60 65 70 45 50 55 60 65 70 75 80 85 90 45 50 55 60 65 70 75 80 85 90 60 65 70 75 80 85 90 95 100 105 130 155 D 55 60 65 70 75 80 85 90 95 100 125 150 65 70 75 80 85 90 95 100 105 130 155 65 70
, 100 25 10, 20, 30, 40, 50, 75, 100 32 10, 20, 30, 40, 50, 75, 100 10 75, 100, 125, 150 15 75, 100, 125, 150 20 125, 150, 175, 200 25 125, 150, 175, 200 32 125, 150, 175, 200 Courtesy of Steven Engineering, Inc. !
, 100 25 10, 20, 30, 40, 50, 75, 100 32 10, 20, 30, 40, 50, 75, 100 10 75, 100, 125, 150 15 75, 100, 125, 150 20 125, 150, 175, 200 25 125, 150, 175, 200 32 125, 150, 175, 200 Courtesy of Steven Engineering, Inc. !
Note 2) Dimensions inside ( ) are for 75, 100st.
100 20 17 35 12.5 72 85 97 110 135 160 185 25 37.5 50 75 100 125 25 17 35 12.5 72 85 97 110 135 160 185 25 37.5 50 75 100 125 32 17 35 12.5 77 90 102 115 140 165 190 25 37.5 50 75 100 125 40 17 46 Over 301 stroke: Long stroke. 9-2-22 21 Series CLM2 Fine Lock Cylinder Double Acting, Single Rod Axial Foot Style (L) Rc BQ locking port for pressurizing (Plug cap with breathing port at spring