Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Built-in magnet 2 pcs. 1 pc.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Additional cylinder tube length Full stroke RHC CDQ2 MK(2) RS Q G Overall length of cylinder tube RS H A Comparison of cylinder tube overall length (mm) RZQ Full stroke = 300 mm (150 + 150 = 300 mm in case of CG1BN) MI W S CG1BN150+150-XC11 Dual stroke
4 CUJ CU CQS CQM CQ2 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com !0 u y RQ MU 32 to 50 With auto switch (Built-in magnet) !6 q e r t !5 i o !1 !3 !2 !7 w !4 D-X 20Data !0 u y Description No.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com CX A shock absorber can be installed (option). D-X Can be mounted on two sides. 20Mounting from the bottom side Mounting from the upper side Data Guide of high rigidity Adjusting bolt with bumper is standard.
MB-F05 MB-F06 MB-F08 MB-F10 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Single clevis MB-C03 MB-C04 MB-C05 MB-C06 MB-C08 MB-C10 100 1000 Double clevis MB-D03 MB-D04 MB-D05 MB-D06 MB-D08 MB-D10 Note 1) Order two axial foot brackets per cylinder.
0.5 W W W F 10.0 (40) (40) (40) 74 36 0.7 93 (40) 54 37 26 33 0.3 69 G 41 27 39 19 25 0.5 52 C8525 33 22 32 15 20 0.7 C8520 43 1.0 Foot: L Rod side flange: F Head side flange: G (100) (40) (40) (40) (40) (100) 0.3 L (100) (40) (40) (40) (40) (100) 0.5 W W F W (100) (40) (40) (40) (40) (100) 0.7 (40) (40) (40) (100) 79 38 0.3 0.1 G (40) (40) 60 29 37 0.5 76 600 500 400 300 1000 1100 900 800
North American Branch Offices For a branch office near you call: 1-800-SMC-SMC1 (762-7621) SMC Pneumatics lnc. (Milwaukee) SMC Pneumatics lnc. (Richmond) SMC Pneumatics Inc. (Cleveland) 2305 East Aurora Rd., Unit A-3 Twinsburg, OH 44087 Tel: (330) 963-2727 FAX: (330) 963-2730 SMC Pneumatics Inc.
Applicable models: D-A73, A73H, A73C, C73, C73C, D-97, 93A, A93, A93V, D-A33A, A34A, A44A, D-B53, B54 2) However, in the case of a 2 color indicator type auto switch (D-A79W, B59W), note that the switch will be in a normally ON condition if connections are reversed. Never carry a cylinder by its lead wires.
Bore size 32 mm 32 40 mm 40 50 mm 50 63 mm 63 Action Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Double acting D Applicable Auto Switch/Refer to page 12-13-1 for further information on auto switches.
W kg (800) 50 l (600) 40 Caution W l Mass m 30 MY1H40 MY1H40 MY1H40 1. If the cylinder mounting surfaces are not measured accurately, using a side support may cause poor operation. Therefore, be sure to level the cylinder tube when mounting.
used according to buckling strength 100.0 Nominal symbol C76 Mounting bracket diagram 32 40 (MPa) Lateral load applied to the rod end fR (N) Foot: L Rod side flange: F Head side flange: G 0.3 58 54 10.0 L C7640 44 0.5 40 W W W F 36 0.7 33 C7632 24 0.3 23 G 17 0.5 16 1.0 13 0.7 13 Clevis: C, D Rod side trunnion: U 0.3 C 0.5 W W D 0.7 0.1 (100) (100) 0.3 600 500 400 300 1000 1100 900 800
I T C H C A P A B L E A U T O S W I T C H 2 Pieces S 1 Piece See Accessories Without Auto Switch D With Auto Switch S T R O K E A D J U S T M E N T S T R O K E ( I N C H) M O U N T I N G With Adjustment Bolts (Std) B With Shock Absorber BC With Cap Type Shock Absorber BCS With One Cap Type Shock Absorber B Housing fixed P End plate fixed 100 1 200 2 300 3 400 4 500 5 600 6 700 7 800
Bore Size: 40mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: H (Large Holding Force), Stroke: 800mm
Type: Rodless Cylinder, Cylinder Inner Diameter(Ø): 40, Stroke(mm): 800, Max.
1.25 8 132 129 6 65 0.2 46 10 77 75, 100 77.5 53.5 10 to 50 79 53 +0.2 0 100 89 63 117 114 99 13 M10 x 1.5 10 156 153 6.5 80 0.2 56.6 10 94 75, 100 89 63 P Bore size (mm) 63 80 100 N OA OB Q RA RB V W Z Rc 1/4 TN NPT 1/4 TF G 1/4 M10 x 1.5 14 15 18 10.5 69 12 19 9 G 3/8 M12 x 1.75 17.5 Rc 3/8 NPT 3/8 16 22 13.5 89 14 26 11 Rc 3/8 NPT 3/8 G 3/8 M12 x 1.75 17.5 23 22 13.5 113 16 26 11 800
D-A73, D-A80 D-A72H, O.A73H, O.A76H, D-A8OH, D-F7NTL, D-F7P, D-F79, D.F79W, O-J79, D..t79W D-Fltr WV, D-F7tr V t,.A73C, D-A80C, D-J79C op6drirE ElE6 (* lid be*rw) I, Dimensiltn / Operating Range Series NCDQT Solid.
D-A6 o D-A73 & D-A53 0or 24VDC) have a lighr emitting diode as an indicator light, and thsrefore, have poladty. lf using 24VDC, the black lead Wire is (-) side, and the red lead is (+) side. lf connection is revrsed, the light will not go on ahhough the switch wi operate.
(Applicable to round bar, chamfered, roller type rod end configurations.) 1.0 1.0 RSH Operating pressure P [MPa] Operating pressure P [MPa] RSQ20 RSQ40 RSQ12 MIW MIS RSQ16 RSQ32 0.5 0.5 RSQ50 0 600 800 400 200 0 50 100 Lateral load F [N] Lateral load F [N] D-X 559-4 A Stopper Cylinder Fixed Mounting Height RSQ Series 12, 16, 20, 32, 40, 50 RoHS How to Order Q M9BW 12 10 RS D D L B 12 Z RS
North American Branch Offices For a branch office near you call: 1-800-SMC-SMC1 (762-7621) SMC Pneumatics lnc. (Milwaukee) SMC Pneumatics lnc. (Richmond) SMC Pneumatics Inc. (Cleveland) 2305 East Aurora Rd., Unit A-3 Twinsburg, OH 44087 Tel: (330) 963-2727 FAX: (330) 963-2730 SMC Pneumatics Inc.