Piping: Standard, Bore Size: 15mm, Port Thread: (M5 Thread-6~15mm)(Rc-20~63mm), Stroke: 450mm
Type: Rodless Cylinder, Cylinder Inner Diameter(Ø): 15, Stroke(mm): 450, Max.
Load voltage AC DC Auto switch model Lead wire length (m) Indicator light Pre-wire connector Special function Type Electrical entry Wiring (Output) Applicable load 0.5 (Nil) 3 (L) 5 (Z) Perpendicular In-line 3-wire (NPN equivalent) IC circuit A96V A96 5 V Reed switch Solid state switch Yes Yes Grommet 100 V 24 V 12 V A93 M9N M9P M9B F9NW F9PW F9BW A93V M9NV M9PV M9BV F9NWV F9PWV F9BWV
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 450, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches
Ex.) 25A-CS2D125-450, mounting angle 0 This is clevis type, so use graph 2 and read nodal point of mounting angle 0and curb line, which is stroke approx. 480mm. The cylinder stroke 450mm is smaller than this stroke, therefore it is safe.
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 450, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: M9N, Lead Wire Length
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 450, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 450, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.2 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: M9N, Lead Wire Length(
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 450, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: M9N, Lead Wire Length
Auto switch model Lead wire length (m) Load voltage Wiring (Output) Pre-wired connector Applicable load DC AC Indicator light Electrical entry Type Special function Perpendicular In-line 0.5 (Nil) 1 (M) 5 (Z) 3 (L) M9N M9P M9B M9NW M9PW M9BW M9NA1 M9PA1 M9BA1 P3DWA M9NV M9PV M9BV M9NWV M9PWV M9BWV M9NAV1 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire (PNP) 2-wire 3-wire (NPN) 3-wire
Type: Rodless Cylinder, Cylinder Inner Diameter(Ø): 10, Stroke(mm): 450, Max.
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 450, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.2 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: M9N, Lead Wire Length(
Type: Rodless Cylinder, Cylinder Inner Diameter(Ø): 25, Stroke(mm): 450, Max.
Type: Rodless Cylinder, Cylinder Inner Diameter(Ø): 15, Stroke(mm): 450, Max.
Piping: Standard, Bore Size: 15mm, Port Thread: (M5 Thread-6~15mm)(Rc-20~63mm), Stroke: 450mm, Auto Switch: M9B--Solid State , Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)
Piping: Standard, Bore Size: 15mm, Port Thread: (M5 Thread-6~15mm)(Rc-20~63mm), Stroke: 450mm, Auto Switch: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: Z (5m)
Piping: Standard, Bore Size: 15mm, Port Thread: (M5 Thread-6~15mm)(Rc-20~63mm), Stroke: 450mm, Auto Switch: M9B--Solid State , Gen. Purpose, 2 Wire, Horizontal
Piping: Standard, Bore Size: 15mm, Port Thread: (M5 Thread-6~15mm)(Rc-20~63mm), Stroke: 450mm, Auto Switch: M9P--Solid State , Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: SDPC (0.5m Cord Length, M12-4 Pin Connector), Number: 3 pcs.
Piping: Standard, Bore Size: 15mm, Port Thread: (M5 Thread-6~15mm)(Rc-20~63mm), Stroke: 450mm, Auto Switch: M9BW--Solid State, 2-color Indication, 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m)
Piping: Standard, Bore Size: 15mm, Port Thread: (M5 Thread-6~15mm)(Rc-20~63mm), Stroke: 450mm, Auto Switch: M9B--Solid State , Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -