Summary of Product parts LED Display The status display LED displays the power supply and communication status. 2 1 4 5 3 Display Content ST(M) Displays the diagnostic status of the unit. End plate bracket (EX600-ZMA2) 6 12 EX600-SEC1 / EX600-SEC2 Displays the status of the power supply voltage for control and input. PWR Displays the status of the power supply voltage for outputs.

Description Function 1 11 2 4 7 10 Displays the status of the unit. 5 3 9 8 6 DIN rail mounting groove 4 1 Intermediate reinforcing brace (EX600-ZMB2) 12 Intermediate reinforcing brace (EX600-ZMB1) DIN rail 2 Valve plate (EX600-ZMV ) 1 End plate bracket (EX600-ZMA2) 2 3 4 Refer to the SMC website (URL http://www.smcworld.com) to obtain more detailed information about setting and adjustment

Description Function 2 1 4 11 7 10 Displays the status of the unit. 5 3 9 8 6 12 DIN rail mounting groove 4 1 Intermediate reinforcing brace (EX600-ZMB2) Intermediate reinforcing brace (EX600-ZMB1) DIN rail 2 Valve plate (EX600-ZMV ) 1 End plate bracket (EX600-ZMA2) 2 3 4 Refer to the product catalogue or SMC website (URL http://www.smcworld.com) to obtain more detailed information about

Description Function 1 11 2 4 7 10 Displays the status of the unit. 5 3 9 8 6 DIN rail mounting groove 4 1 Intermediate reinforcing brace (EX600-ZMB2) 12 Intermediate reinforcing brace (EX600-ZMB1) DIN rail 2 Valve plate (EX600-ZMV ) 1 End plate bracket (EX600-ZMA2) 2 3 4 *: If a node is set to 00 or a number over 65, the "LERR" LED will light up. *: "LERR" LED light to a switch setting other

Description Function 1 10 2 6 9 Displays the status of the unit. 4 3 8 7 11 5 DIN rail mounting groove 4 1 Intermediate reinforcing brace (EX600-ZMB2) 12 Intermediate reinforcing brace (EX600-ZMB1) DIN rail 2 Valve plate (EX600-ZMV ) 1 End plate bracket (EX600-ZMA2) 2 3 4 Refer to the SMC website (URL http://www.smcworld.com) to obtain more detailed information about setting and adjustment

Wireless System EX600-W Series RoHS How to Order EN W EX600 1 SI Unit Wireless compatible Output type Symbol Specications 1 PNP 2 NPN SI unit Symbol Specications Note EN Wireless master unit For EtherNet/IP SV Wireless slave unit Wireless slave unit Wireless master unit DX EX600 P D Digital Input Unit Input type Number of inputs and Connector Symbol Description P PNP N NPN Symbol Number

Base Mounted Plug-in Unit How to Order Manifold VQC1000 Series kit F P VV5QC 1 1 08 FD1 C6 M L T VV5QC 1 1 08 SDQ C6 S kit Base mounted plug-in VQC1000 series Enter EX600-compliant S kit only. Enter EX250-compliant S kit only. Valve stations Input block specification (Enter EX250-compliant S kit only.)

They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC)*1), and other safety regulations. *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic fluid power -General rules relating to systems IEC 60204-1: Safety of machinery -Electrical equipment of machines (Part 1: General requirements) ISO 10218-1

Brackets Accessary i Symbol Contents B1 EXW1-NT1 For the following EX600-W models EX600-WEN1/2 EX600-WPN1/2 EX600-WSV1/2 EXW1-AB1 B2 EXW1-NT1 For the EXW1 series EXW1-AB2 As the brackets and the NFC Reader/Writer worsen the performance of wireless communication in the 2.4 GHz band, use them only during configuration and remove them during normal operation.

Note) Conforms to ISO1179-1 Without input block M12, 2 inputs M12, 4 inputs M8, 4 inputs Nil 1 2 3 Kit type/Electrical entry/Cable length (Refer to page 4) End plate (Enter EX600-compliant S kit only.) Number of input blocks (Enter EX250/600-compliant S kit only.)

Valve diagnostics 1 Table 9-9 Valve diagnostics 1 Bit 0 12 0: 1 1 34 0: 1 2 56 0: 1 3 78 0: 1 4 910 0: 1 5 1112 0: 1 6 1314 0: 1 7 1516 0: 1 9.1.2.3. General diagnostics 2 Table 9-10 General diagnostics 2 Bit 0 1 0:1: 1 2 0:1: 2 3 0:1: 3 4 0:1: 4 5 0:1: 5 6 0:1: 6 7 0:1: 7 8 0:1: 9.1.2.4.

power supply voltage 1: The power supply voltage exceeds the specified value. 0: Other than the above case. 10 Alarm generation 1: Any one of bits 4 to 9 is "1". 0: Bit 4 to 9 of the Bit offset are "0". 11 Internal communication error 1: Error 0: No error 12 Built-in solenoid valve error 1: Error 0: No error 13 Internal system error 1: Error 0: No error 14 EEPROM error 1: EEPROM error 0:

Type: Cable, Communication Protocol: -, Output Format: -, Type: Cable for handheld terminal, Number of Inputs/Outputs: -, Disconnection Detection: -, Connector: -, Mounting Method: -, Dimension: Cable Length 1 m, Option: -

Type: Cable, Communication Protocol: -, Output Format: -, Type: Cable for handheld terminal, Number of Inputs/Outputs: -, Disconnection Detection: -, Connector: -, Mounting Method: -, Dimension: Cable Length 3 m, Option: -

._3d_items_collection = {}; } SMC AN20-C10 silencer, AN SILENCER (must be purchased in multiples of 10) $6.50 + Add to Quote Add To Cart Add to Cart SMC EX600-SPN1 ex300, EX300

._3d_items_collection = {}; } SMC AN20-C10 silencer, AN SILENCER (must be purchased in multiples of 10) $6.50 + Add to Quote Add To Cart Add to Cart SMC EX600-SPN1 ex300, EX300

._3d_items_collection = {}; } SMC AN20-C10 silencer, AN SILENCER (must be purchased in multiples of 10) $6.50 + Add to Quote Add To Cart Add to Cart SMC EX600-SPN1 ex300, EX300

._3d_items_collection = {}; } SMC AN20-C10 silencer, AN SILENCER (must be purchased in multiples of 10) $6.50 + Add to Quote Add To Cart Add to Cart SMC EX600-SPN1 ex300, EX300

._3d_items_collection = {}; } SMC AN20-C10 silencer, AN SILENCER (must be purchased in multiples of 10) $6.50 + Add to Quote Add To Cart Add to Cart SMC EX600-SDN2A devicenet