Cooling Capacity: 018 [1600/1800 W (50/60 Hz)], Cooling Method: Air-cooled, Pipe Thread: Rc, Option 1: None, Option 2: -

Cooling Capacity: 018 [1600/1800 W (50/60 Hz)], Cooling Method: Air-cooled, Pipe Thread: Rc, Option 1: None, Option 2: w/Feet, w/o Rack Mounting Brackets

Cooling Capacity: 018 [1600/1800 W (50/60 Hz)], Cooling Method: Air-cooled, Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: High-pressure Pump Mounted, Option 2: No Flow Sensor or Retaining Clip

Cooling Capacity: 018 [1600/1800 W (50/60 Hz)], Cooling Method: Air-cooled, Pipe Thread: F [G (with Rc-G Conversion Fitting Set], Option 1: None, Option 2: -

Cooling Capacity: 018 [1600/1800 W (50/60 Hz)], Cooling Method: Air-cooled, Pipe Thread: Rc, Option 1: High-pressure Pump Mounted, Option 2: w/Feet, w/o Rack Mounting Brackets

Cooling Capacity: 018 [1600/1800 W (50/60 Hz)], Cooling Method: Air-cooled, Pipe Thread: Rc, Option 1: None, Option 2: No Flow Sensor, Water Leakage Sensor, Particle Filter, Bypass Valve or Retaining Clip

Cooling Capacity: 018 [1600/1800 W (50/60 Hz)], Cooling Method: Air-cooled, Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: Applicabe to DI Water Piping, Option 2: -

Cooling Capacity: 018 [1600/1800 W (50/60 Hz)], Cooling Method: Air-cooled, Pipe Thread: F [G (with Rc-G Conversion Fitting Set], Option 1: M + T, Option 2: No Flow Sensor, Water Leakage Sensor, Particle Filter, Bypass Valve or Retaining Clip

Cooling Capacity: 018 [1600/1800 W (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: Rc, Option 1: MT (M + T)

Cooling Capacity: 018 [1600/1800 W (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: N [NPT (with Rc-NPT Conversion Fitting Set], Option 1: None, Option 2: Y (w/Feet, w/o Rack Mounting Brackets)

Applicable bore size B C D d H TN-020B 20 26 28 25.5 M20 x 1.5 10 TN-032B 25, 32 32 34 31.5 M26 x 1.5 10 TN-040B 40 41 45 40.5 M32 x 2 10 Part no.

10 10 14 14 15 17 17 21 21 51 58 58 71 72 6 7 7 10 10 14 18 18 22 26 30 35 40 48 58 M14 x 1.5 27 30 31 37 40 1/4 3/8 3/8 1/2 1/2 10 12 16 20 25 16 19 23 28 36 30 35 35 40 40 27 32 32 37 37 60 70 85 102 116 22 27 27 32 41 44 52 64 78 92 10 12 16 20 25 15 18 25 8 11 11 13 16 M8 x 1.25 M18 x 1.5 M10 x 1.25 M18 x 1.5 M12 x 1.75 M22 x 1.5 31.5 M12 x 1.75 M26 x 1.5 35.5 6-8-36 37 Series CA2Q Air

Ambient temperature (C) Recommended circulating fluids 10 to 45 Tap water, ethylene glycol aqueous solution 15(wt)% -5 to 10 Ethylene glycol aqueous solution 15(wt)% -20 to -5 Ethylene glycol aqueous solution 40(wt)% Circulating fluid temperature(C) Recommended circulating fluids 10 to 35 Tap water, ethylene glycol aqueous solution 15(wt)% 5 to 10 Ethylene glycol aqueous solution 15(wt)%

capacity [kW] 8 8 6 6 4 4 2 2 0 0 5 10 15 20 25 30 35 5 10 15 20 25 30 35 Circulating fluid temperature [oC] Circulating fluid temperature [oC] 50Hz 60Hz Fig. 8-5 Cooling capacity(HRS100-A-20/40/46-) 8.4.2 HRS150-A-20/40/46: Ambient temperature: 32 oC : Ambient temperature: 40oC : Ambient temperature: 45 oC 18 18 16 16 14 14 Cooling capacity [kW] Cooling capacity [kW] 12 12 10 10 8 8 6 6

Air Pressure settiflq range 0 -3oinHs (0 760mmHo) Hystersis 3% or less (fixed) Accuracv a3% full scale (40 100"F) 15% full scale (32 140'F) Supply voltage 12 24VDC (Ripple r'10% max.) Port srze M5 ( 10 32 nom.)

Air Pressure settiflq range 0 -3oinHs (0 760mmHo) Hystersis 3% or less (fixed) Accuracv a3% full scale (40 100"F) 15% full scale (32 140'F) Supply voltage 12 24VDC (Ripple r'10% max.) Port srze M5 ( 10 32 nom.)

Refer to pages 9 and 10 for detailed selection procedures. 3 Model Selection Series MY2 Moment/MY2C MY2C/M1 MY2C/M3 MY2C/M2 50 40 50 40 50 40 30 30 30 20 20 20 10 10 10 MY2C40 MY2C40 Moment Nm Moment Nm Moment Nm MY2C40 5 5 5 4 4 4 3 3 3 MY2C25 MY2C25 2 2 MY2C25 2 MY2C16 1 1 1 MY2C16 MY2C16 0.5 0.5 0.5 100 200 300400500 1000 1500 100 200 300 400500 1000 1500 100 200 300 400500 1000 1500 Piston

unit 1000 1000 Air cushion 500 400 300 500 400 300 L unit Air cushion 200 200 1002 3 4 5 10 20 50 100 1 2 3 4 5 10 20 30 400 50 Caution Load weight (kg) Load weight (kg) 1.