Never use in an atmosphere of explosive gases. The construction of auto switches is not intended to prevent explosion. Never use in an atmosphere with an explosive gas since this may cause a serious explosion. 2. Do not use in an area where a magnetic field is generated. Auto switches will malfunction or magnets inside cylinders will become demagnetized.
Operation stop Combination Symbol: D1 Combination Symbol: D4 An N.C. solenoid valve is used for the vacuum release valve. An external supply valve must be provided. An external valve must be provided to serve as the supply valve. An air operated N.C. valve is used for the vacuum release valve.
Note 4) When n is an odd number, an even number that is one larger than this odd number is used for the calculation. However, the minimum even number is 4. So, 4 is used for the calculation when n is 1 to 3.
An external pilot style that can be used individually is available as a made-to-order. For details, refer to the page 4-6-46.
As the vacuum power of an ejector (venturi) rises, the vacuum flow actually lowers. When an ejector is used at its highest possible vacuum value, the vacuum flow will lower. Due to this, the amount of time needed to achieve adsorption is lengthened.
Never use in an atmosphere of explosive gases. The construction of auto switches is not intended to prevent explosion. Never use in an atmosphere with an explosive gas since this may cause a serious explosion. 2. Do not use in an area where a magnetic field is generated. Auto switches will malfunction or magnets inside actuators will become demagnetized. 3.
It turns OFF when an alarm occurs or when JOG movement takes place.
Note 3) When n is an odd number, an even number that is one larger than this odd number is used for the calculation.
Panel mount adapter ZS-46-B Panel mount adapter + Front protection cover ZS-46-D Lead wire with connector ZS-46-3L 3-core, 2 m, Non-waterproof (Without waterproof cover) Front protection cover ZS-27-01 D Panel mount adapter + Front protection cover ZS-46-D R1/8 Piping adapter ZS-46-N1 NPT1/8 Piping adapter ZS-46-N2 9 3-Screen Display High-Precision Digital Pressure Switch ZSE20(F)/ISE20
For installation and removal, use an appropriate pair of pliers (tool for installing a type C snap ring).
(An assembly is shipped under the condition shown in the figure.) Note) The EXH port may be either on the lead wire side or on the end plate side. (An assembly is shipped under the condition shown in the figure.)
If operated with the workpiece gripping point beyond the indicated ranges, an excessive offset load will be applied to the sliding section of the fingers, which can have an adverse effect on the service life of the product.
46 119.2 58 136 173 MORE DIMENSIONS S E E N E X T P A G E Courtesy of Steven Engineering, Inc. !
The connector size of the motor cable is different from that of the electric actuator with an incremental encoder. The motor cable connector of an electric actuator with a battery-less absolute encoder is different from that of an electric actuator with an incremental encoder.
The cushion effect (smooth start-up, soft stop) cannot be obtained in an intermediate stop or a return from an intermediate stop using an external stopper, etc.
This may cause unevenness in the mounting surface, play in the guide or an increase in the sliding resistance. 5. Do not apply strong impact or an excessive moment while mounting a workpiece. Otherwise, lubrication can run out. If an external force over the allowable moment is applied, it may cause play in the guide or an increase in the sliding resistance.
Never use in an atmosphere of explosive gases. The construction of auto switches is not intended to prevent explosion. Never use in an atmosphere with an explosive gas since this may cause a serious explosion. 2. Do not use in an area where a magnetic field is generated. Auto switches will malfunction or magnets inside actuators will become demagnetized. 3.
Fit an auto switch into the auto switch mounting groove to set it roughly to the mounting position for an auto switch. 4. After confirming the detecting position, tighten up the mounting screw (M2.5) attached to an auto switch, and secure the auto switch. 5. When changing the detecting position, carry out in the state of 3.
Note 1) This cylinder cannot perform an intermediate stop using an air pressure circuit in vertical operation. In this case, an intermediate stop can be performed only by using an external stopper, etc. Made-to-order products should be considered, too, depending on an operating environment, etc.