Rated Distance Range: 0.05 to 0.30mm, Piping Specifications: Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm, Output Specifications: PNP Output, Unit Specification: w/Unit Conversion Function, Stations: 4, Cable Option: Straight, Bracket Option: Bracket, Control Unit: Control Unit w/o Pressure Gauge; Supply
Rated Distance Range: 0.01 to 0.03mm, Piping Specifications: Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm, Output Specifications: PNP Output, Unit Specification: w/Unit Conversion Function, Stations: 1, Cable Option: Right Angle, Bracket Option: Bracket, Control Unit: Control Unit w/o Pressure Gauge; Supply
Rated Distance Range: 0.01 to 0.03mm, Piping Specifications: Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm, Output Specifications: PNP Output, Unit Specification: w/Unit Conversion Function, Stations: 4, Cable Option: Right Angle, Bracket Option: Bracket, Control Unit: Control Unit w/o Pressure Gauge; Supply
Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: N (NPN Output), Unit Specification: M (Fixed SI Unit), Stations: 3, Cable Option: L (Right Angle), Bracket Option: B (Bracket), Control Unit: L0 (Control Unit w/o Pressure
Note 4) When multiple symbols are specified, indicate them alphabetically. 465 VQ4000 Series Kit (Lead wire cable) L 91 1/8" PE. port 38 70 18 18 2 x G3/4 (Electrical entry) 17.2 PE 29.7 41.7 R2 R1 5 P 1 3 SMC 1/4", 3/8" C6, C8, C10, C12, N7, N9, N11 4(A), 2(B) port Lead wire length 1/2" 1(P), 5(R1), 3(R2) port L0: 600 mm M5 x 0.8 Ground screw L1: 1500 mm 3.5 163 L2: 3000 mm 47 106 71.7
2 E 1 0 E E _ E 5 E E c r l 0 1 2 3 4 5 6 7 I I 101112131415 Distance from cylinder axis: Lo (cm) Example The required load, Fo =100(N) and the moment arm, L0 = Bcm refering to Data 1, draw a vertical line from the 8cm value of the horizontal axis.
(cm) Distance from cylinder shaft center L0 (cm) Distance from cylinder shaft center L0 (cm) 100 REBR32 REBR25 10 REBR15 1 0.1 100 200 300 400 600 500 Maximum speed U (mm/s) 62 Series REBR Model Selection 3 Design Parameters 2 Maximum Load Weight when Loaded Directly on Body Cylinder Self Weight Deflection Vertical Operation When the cylinder
kit Stations (1 to 8) L1 kit Stations (1 to 8) L2 kit Stations (1 to 8) F1 F2 F3 P1 P2 P3 L0 L1 L2
2 E 1 0 E E _ E 5 E E c r l 0 1 2 3 4 5 6 7 I I 101112131415 Distance from cylinder axis: Lo (cm) Example The required load, Fo =100(N) and the moment arm, L0 = Bcm refering to Data 1, draw a vertical line from the 8cm value of the horizontal axis.
Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Output Specifications: P (PNP Output), Unit Specification: M (Fixed SI Unit), Stations: 2, Cable Option: L (Right Angle), Bracket Option: B (Bracket), Control Unit: L5 (w/Control Unit, Supply Port: Left Side, With regulator, Round type pressure gauge; 0.4 MPa)
Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: N (NPN Output), Unit Specification: M (Fixed SI Unit), Stations: 2, Cable Option: L (Right Angle), Bracket Option: B (Bracket), Control Unit: L1 (w/Control Unit, Supply
Rated Distance Range: F (0.01 to 0.03mm), Piping Specifications: F (Supply Side: G 1/8, Detection Side: G 1/8), Output Specifications: P (PNP Output), Unit Specification: M (Fixed SI Unit), Stations: 2, Cable Option: L (Right Angle), Bracket Option: B (Bracket), Control Unit: L1 (w/Control Unit, Supply Port: Left Side, With regulator, Round type pressure gauge)
Rated Distance Range: F (0.01 to 0.03mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: P (PNP Output), Unit Specification: M (Fixed SI Unit), Stations: 2, Cable Option: L (Right Angle), Bracket Option: B (Bracket), Control Unit: L1 (w/Control Unit, Supply
Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: B (PNP, 2 Outputs), Unit Specification: M (Fixed SI Unit), Stations: 2, Cable Option: L (Right Angle), Bracket Option: B (Bracket), Control Unit: L1 (w/Control Unit, Supply
Rated Distance Range: F (0.01 to 0.03mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: B (PNP, 2 Outputs), Unit Specification: M (Fixed SI Unit), Stations: 2, Cable Option: L (Right Angle), Bracket Option: B (Bracket), Control Unit: L1 (w/Control Unit, Supply
Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: P (PNP Output), Unit Specification: M (Fixed SI Unit), Stations: 2, Cable Option: L (Right Angle), Bracket Option: B (Bracket), Control Unit: L1 (w/Control Unit, Supply
Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: N (NPN Output), Unit Specification: M (Fixed SI Unit), Stations: 2, Cable Option: L (Right Angle), Bracket Option: B (Bracket), Control Unit: L5 (w/Control Unit, Supply
Rated Distance Range: H (0.05 to 0.30mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: N (NPN Output), Unit Specification: M (Fixed SI Unit), Stations: 2, Cable Option: L (Right Angle), Bracket Option: B (Bracket), Control Unit: L1 (w/Control Unit, Supply
Rated Distance Range: G (0.02 to 0.15mm), Piping Specifications: C (Supply Side: Rc 1/8, Detection Side: ø6 One-touch Fitting or ø4 One-touch Fitting in case of Rated Distance Range 0.01 to 0.03 mm), Output Specifications: A (NPN, 2 Outputs), Unit Specification: M (Fixed SI Unit), Stations: 2, Cable Option: L (Right Angle), Bracket Option: B (Bracket), Control Unit: L1 (w/Control Unit, Supply
Rated Distance Range: 0.01 to 0.03mm, Piping Specifications: Supply Side: G 1/8, Detection Side: G 1/8, Output Specifications: PNP Output, Unit Specification: Fixed SI Unit, Stations: 2, Cable Option: Right Angle, Bracket Option: Bracket, Control Unit: w/Control Unit, Supply Port: Left Side, With regulator, Round type pressure gauge, 2 Port Solenoid Valve Rated Voltage: -