Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: A (Bracket A, Interchangeable with ISE70), Operation Manual/Calibration Certificate: K (
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: A (Bracket A, Interchangeable with ISE70), Operation Manual/Calibration Certificate: T (
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only), Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70)
This is a legacy product, and replaced byISE70-N02-L2, PRESSURE SWITCH, DIGITAL, INSTRUMENTATION, ISE70/75 PRESSURE SWITCH, DA, ISE70/75 1/4 PT VERSION, .74287 lb
)/4 H_1(AB)/2 (n_1B(AB)/4) 1 digit (P1LP1H n1Ln1H) 26 -37No.PF-OMJ0005CN-I [F10] OFF 25 100 24 551005009.5 221002003.8 <> [F10] [EEP] OFF 5 2 [F10] -38No.PF-OMJ0005CN-I [F11] OFF [---] <> [F11] [AFL] 1.5s 100ms [F11] -39No.PF-OMJ0005CN-I [F12] 30 <> [F12] [ECo] [F12] 30 () -40No.PF-OMJ0005CN-I [F13] 46 <> [F13] [Pin] [F13] -41No.PF-OMJ0005CN-I [F98] <> [F98]
AS231F-N02 NPT1/4 20, 25, 32, 40 AS321F-N02 AS331F-N02 NPT1/4 40, 50, 63 AS321F-N03 AS331F-N03 NPT3/8 40, 50, 63 AS421F-N04 AS431F-N04 NPT1/2 63, 80, 100 Note 1) Elbow type only.
-07S 18 15 36.7 35.4 34.6 29.6 17.5 18.5 41.7 40.4 11 18.5 46.5 5/16" 15.2 28.2 ASD430FG-N02-09S NPT1/4 21 19.7 49.3 3/8" 18.5 31 ASD430FG-N02-11S 17 48.7 1/4" 13.2 25.6 ASD530FG-N02-07S 20.3 41.9 43.8 43 38 19 18.5 46.9 48.8 15.4 23 51.3 5/16" 15.2 28.2 19.8 ASD530FG-N02-09S NPT1/4 21 23.1 54.1 3/8" 18.5 32.6 ASD530FG-N02-11S 17 48.7 1/4" 13.2 25.6 ASD530FG-N03-07S 20.3 41.9 41.5 40.3 35.3
Pressure Range: ISE70 (0 to 1 MPa), Piping: F02 (G 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70)
Pressure Range: ISE70 (0 to 1 MPa), Piping: 02 (Rc 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70)
Pressure Range: ISE70 (0 to 1 MPa), Piping: 02 (Rc 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: M (SI Unit Only), Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70)
Pressure Range: ISE70 (0 to 1 MPa), Piping: F02 (G 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: A (Bracket A, Interchangeable with ISE70)
Pressure Range: ISE70 (0 to 1 MPa), Piping: F02 (G 1/4), Output Specification: AB (Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: A (Bracket A, Interchangeable with ISE70)
Pressure Range: 0 to 1 MPa, Piping: NPT 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: -, Lead Wire: -, Bracket: -, Operation Manual/Calibration Certificate: -
[cm] -70No.PF-OMO0004CN-E PFMB7201-02 PFMB7201-N02 17 2x Rc1/4 NPT1/4 -71No.PF-OMO0004CN-E PFMB7201-02L PFMB7201-N02L 2x Rc1/4 NPT1/4 17 -72No.PF-OMO0004CN-E PFMB7201S-02 PFMB7201S-N02 2x Rc1/4 NPT1/4 -73No.PF-OMO0004CN-E PFMB7201S-02L PFMB7201S-N02L 2x Rc1/4 NPT1/4 17 -74No.PF-OMO0004CN-E PFMB7201-F02 21 2x G1/4 -75No.PF-OMO0004CN-E PFMB7201-F02L 2x G1/4 21 -76No.PF-OMO0004CN-E PFMB7201S-F02
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: S (Lead Wire with M12 Connector; Straight, 5 m)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m), Bracket: None, Operation Manual/Calibration Certificate
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: L (Lead Wire with M12 Connector; Right-angled, 5 m)
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: B (Bracket B), Operation Manual/Calibration Certificate: K (Operation Manual + Calibration
Pressure Range: ISE70 (0 to 1 MPa), Piping: N02 (NPT 1/4), Output Specification: L2 (I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type]), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: None, Operation Manual/Calibration Certificate: K (Operation Manual + Calibration Certificate