SMC Corporation of America
Elite Part Number Search
Search Results "ISG230-N031-CW"

RR CU CZ CX +0.4 +0.2 B + Stroke G Bore size (mm) CU CW CX CZ G L L1 N RR 63 20 30 22 44 38 8 33.5 M8 x 1.25 14 80 27 38 28 56 43 10 43.5 M10 x 1.5 18 Rod end nut L1 100 31 45 32 64 50 12 43.5 M10 x 1.5 22 9-10-23 Single Knuckle Joint Double Knuckle Joint Hole: ND H10 Shaft d9 Applicable bore size (mm) L MM RR1 U1 ND NX Applicable pin part no.

CL + Stroke A + Stroke (mm) Rear flange type A Foot type Front flange type, Rear flange type Double clevis type A Bore size (mm) LB LA LD LE LH LL LS LX LY LZ FD FL FV FX FZ A CD CL CU CW CX CZ RR 8 12 4.5 4.5 29.5 17 2 85 34 52 44 4.5 5.5 25 45 55 114 5 108 7 14 5 10 6 99.5 106.5 9.2 20 5.8 6.6 42 24 3.2 96.4 48 66.5 62 6.6 8 39 48 60 133 8 124 12 18 8 16 9 114 121 14 Series CE1 32, 40,

RR CL + Stroke A + Stroke (mm) Foot Front flange, Rear flange Rear flange Double clevis Bore size (mm) LT* LX FT* FV LA LB LE LH A LD LS LY LZ FD FG FL FX FZ M A A CD CL CU CW CX CZ RR T 32 40 50 63 59 65 148 5.8 11.2 6.6 52.5 30 112.4 57 72.5 71 5.5 69.5 8 48 56 65 34 139 161 10 151 14 20 18 36 10 57.5 71.5 65.5 7 11.2 6.6 33 158.4 64 79.5 78 5.5 76.5 8 54 62 72 40 185 209 10 199 14 22

to 50 29.5 32.5 69 76.5 19.5 22.5 59 66.5 20 25 Bore size (mm) FZ FX FV G L L1 S Rod end nut 60 64 27 31 48 52 39 42 4.5 5 18.5 22.5 40.7 44.2 20 25 L1 Double clevis type: CLQD/CDLQD CD hole H10 Shaft d9 4-M5 x 0.8 Cap bolt Double clevis type (mm) S Stroke range Without auto switch With auto switch Bore size (mm) A B 69 78.5 CL CL B 88 98.5 19.5 22.5 78 88.5 A A + Stroke CL + Stroke RR CW

CU 5 79 88.5 29.5 32.5 5 to 50 5 to 50 20 25 L G B + Stroke +0.4 +0.2 -0.1 -0.3 CZ CX Bore size (mm) CD CX G S CW CZ L L1 RR CU 12 14 8 10 27 31 39.2 43.2 18 20 8 10 16 20 4.5 5 18.5 22.5 9 10 20 25 Rod end nut L1 8 Series CLQ Dimensions/32 Double end tapped: CLQA32 16 3.2 2 x 4-M5 x 0.8 16 3.2 Standard type (through hole): CLQB32 Extension locking LOCK M8 x 1.25 Effective thread depth

Inch L1 L1 A CL A B L B L CL Metric Inch 14 15.5 18.5 22.5 12 16 20 25 11.5 11.5 12.5 14.5 14 15.5 18.5 22.5 40.5 41.5 51 57.5 17 17 19.5 22.5 3.5 3.5 4.5 5 45.5 46.5 61 67.5 22 22 29.5 32.5 39.5 40.5 52 57.5 3.5 3.5 4.5 5 11.5 11.5 12.5 14.5 34.5 35.5 42 47.5 35 to 100 35 to 100 75 to 200 75 to 300 5 to 30 5 to 30 5 to 50 5 to 50 Without/with auto switch Long stroke CD Bore (mm) CT CU CW

Rod end nut L1 Double clevis type Double clevis type/RQD, RDQD mm Bore size (mm) Stroke range (mm) A CL Cap bolt 15 to 50 20 63.5 54.5 CD hole H10 Shaft d9 15 to 50 25 71.5 61.5 mm Bore size (mm) L CU CX +0.4 +0.2 B + Stroke 5 B L L1 CD CU CW CX CZ RR 0.1 0.3 CZ CW RR 20 CL + Stroke A + Stroke 4.5 18.5 12 18 16 9 32 8 8 25 5 22.5 14 20 20 10 36.5 10 10 (Only dimensions A and CL are different

CU CW RR +0.4 +0.2 CX L 0.1 0.3 CZ A + Stroke CL + Stroke [mm] Double Clevis Size Stroke range [mm] A CL CB CD CT Double clevis: LEY E -mmmD 25 32 40 A B C 16 10 to 100 128 119 20 8 5 25 15 to 100 160.5 150.5 10 5 101 to 200 185.5 175.5 32 40 20 to 100 180.5 170.5 10 6 101 to 200 210.5 200.5 CT Size Stroke range [mm] CU CW CX CZ L RR CD hole H10 axis d9 16 10 to 100 12 18 8 16 10.5 9 25

ISG general purpose switch is widely used in machine tool, industrial machines, compressors, chemical plants, power plants, machineries for ships, and for automatic pressure control such as hydraulic, water, liquid and atmospheric pressure., PRESSURE SWITCH, INSTRUMENTATION, ISG PRESSURE SWITCH, 2B, ISG NO SIZE RANPT VERSION, 3.63762 lb

RB A + Stroke FZ J Double clevis style: MQQLD Bore size (mm) Stroke range (mm) A B CL CD CT CU D10 CU 10 to 40 61.5 90.5 5 84.5 4 10 CD hole H10 Shaft d9 Cap bolt 16 10 to 60 70.5 107.5 8 98.5 5 12 -X 20 10 to 60 79 119 10 109 5 14 25 10 to 50, 75, 100 84.5 126.5 10 116.5 5 14 2028 10 to 50, 75, 100 104 148 10 138 6 14 CX +0.4 +0.2 CT Data CZ 0.1 0.3 CW B + Stroke L Bore size (mm) CW CX CZ

D32 112.5 82.5 10 102.5 5 14 20 -X 40 124 92 10 114 6 14 22 50 134.5 96.5 14 124.5 7 20 28 2063 30 146 102 14 132 8 20 CU Data Bore size (mm) L B + Full stroke RR CW CX+0.2 +0.4 CX CZ RR CL + Full stroke CZ -0.3 -0.1 32 18 36 10 A + Full stroke 40 18 36 10 50 22 44 14 63 44 22 14 10-10-11 12 Series RZQ Proper Auto Switch Mounting Position (For Detection of Piston A Stop Position) and Its

RR (mm) Hexagon socket head cap screw Bore size (mm) -0.2 -0.6 CDH9 CL CU CW CX CZ M RR 20 25 32 40 50 63 8 3 12 20 16 35 22 9 M5 8 3 12 20 16 40 26 9 M5 10 5.5 12 22 26 45 32.5 9.5 M6 12 5.5 15 25 28 51 38 12 M6 12 6.5 15 27 32 64 46.5 12 M8 16 6.5 20 32 40 74 56.5 16 M8 8 Series C55 Proper Auto Switch Mounting Position (Detection at Stroke End) and Its Mounting Height Reed switch Solid

LEC SS-T CT [mm] Double Clevis CD hole H10 axis d9 LEC Y LEC Y Size Stroke range [mm] A CL CD CT Motorless 25 15 to 100 160.5 150.5 10 5 105 to 200 185.5 175.5 32 20 to 100 180.5 170.5 10 6 105 to 200 210.5 200.5 LAT CU RR CW L CL + Stroke A + Stroke +0.4 +0.2 CX 0.1 0.3 CZ 63 50 to 200 236.6 222.6 14 8 205 to 500 271.6 257.6 505 to 800 306.6 292.6 LZ LC3F2 Size Stroke range [mm] CU CW

CT [mm] Double Clevis CD hole H10 axis d9 Size Stroke range (mm) A CL CD CT 25 15 to 100 160.5 150.5 10 5 105 to 200 185.5 175.5 32 20 to 100 180.5 170.5 10 6 105 to 200 210.5 200.5 CU RR CW L CL + Stroke A + Stroke +0.4 +0.2 CX 0.1 0.3 CZ 63 50 to 200 236.6 222.6 14 8 205 to 500 271.6 257.6 505 to 800 306.6 292.6 Size Stroke range (mm) CU CW CX CZ L RR 25 15 to 100 14 20 18 36 14.5 10

40 63 9 9 80 92 108 24.4 60 LEY -X5 11LEFS Material: Carbon steel (Nickel plating) * The LL measurement is when the unit is at the retracted stroke end position. 11LEJS 25AA B C Double clevis: LEY ll -lllD 25 32 63 LEC LEC S LEC SS-T CT LEC Y Special cap bolt CD hole H10 axis d9 Motorless Motorless LAT Included parts Double clevis Body mounting bolt Clevis pin Retaining ring LZ CU RR CW

[mm] Double Clevis Size Stroke range [mm] A CL CB CD CT CU CW CX CZ L RR 16 30 to 100 128.4 119.4 20 8 5 12 18 8 16 10.5 9 25 30 to 100 166.2 156.2 10 5 14 20 18 36 14.5 10 101 to 200 191.2 181.2 32 30 to 100 185.6 175.6 10 6 14 22 18 36 18.5 10 101 to 200 215.6 205.6 Material: Cast iron (Coating) The A and CL measurements are when the unit is in the original position.

W W 1 1 W W 2 2 1 1 11 11 12 12 1 32 - 7.3 () 12 1.CW [CW] 2.CCW [CCW] 12 1. [] 2.