250 143 1000 500 250 Different from the initial value. *5.
, 600, 700, 800 4000 32 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 40 5000 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 50 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 6000 63 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 Made to Order Specifications (For details, refer to page 10-21-1.)
, 600, 700, 800 4000 32 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 40 5000 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 50 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 6000 63 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 Made to Order Specifications (For details, refer to page 10-21-1.)
CU Type Solid state switch Reed switch 3-wire: 100 A or less, 2-wire: 0.8 mA or less (4) Leakage current None CQS Note 2) Operating time 1 ms or less (3) 1.2 ms Impact resistance 1000 m/s2 300 m/s2 CQM 50 M or more at 500 M VDC (Between lead wire and case) Insulation resistance Note 3) CQ2 1000 VAC for 1 minute (Between lead wire and case) 1500 VAC for 1 minute (1) (Between lead wire and
Insulation resistance Between external terminal batch and case: 2 M (at 500 VDC) 2 hrs. each in X, Y, Z directions at smaller of 10 to 500 Hz with amplitude 1.5 mm, or acceleration 10 G Vibration resistance Impact resistance 100 G in X, Y, Z directions, 3 times each Note) Not available on analog output type.
to 500 kPa 50 to 500 kPa A sensor may be unconnected or miswired.
Indicator light Electrical entry Lead wire Grommet Oilproof flexible heavy-duty vinyl cord, 2.7 x 3.2, ellipse Switch, 1,000 m/s2 Impact resistance Connector, 300 m/s2 JIS C 4524, JIS C 4525 IEC 947-5-2, NECA 0402 In compliance with IP 67 when coupled 50 M or more (500 VDC Mega) between lead wire and case 1,000 VAC for 1 min.
Calculating motor speed conversion example using an actuator with a 20mm lead and 500[mm/sec] speed.
Bar length [mm] IZN10-G-100-X226 100 IZN10-G-200-X226 200 IZN10-G-300-X226 300 IZN10-G-400-X226 400 IZN10-G-500-X226 500 IZN10-G-600-X226 600 Part no.
Step Axis Movement mode Speed Position Acceleration Deceleration Pushing force Trigger LV Pushing speed Moving force Area 1 Area 2 In position Comments mm/s mm mm/s2 mm/s2 mm mm mm Axis 1 ABS 500 100.00 3000 3000 0 85.0 50 100.0 10.0 30.0 0.5 Axis 2 ABS 500 100.00 3000 3000 0 85.0 50 100.0 10.0 30.0 0.5 0 Axis 3 ABS 500 100.00 3000 3000 0 85.0 50 100.0 10.0 30.0 0.5 Axis 1 INC 500 200.00
CRBU2 Type Solid state switch Reed switch 3-wire: 100 A or less, 2-wire: 0.8 mA or less (4) Leakage current None CRB1 Note 2) Operating time 1 ms or less (3) 1.2 ms Impact resistance 1000 m/s2 300 m/s2 MSU 50 M or more at 500 M VDC (Between lead wire and case) Insulation resistance Note 3) CRJ 1000 VAC for 1 minute (Between lead wire and case) 1500 VAC for 1 minute (1) (Between lead wire
REC Type Solid state switch Reed switch 3-wire: 100 A or less, 2-wire: 0.8 mA or less (4) Leakage current None CX Note 2) Operating time 1 ms or less (3) 1.2 ms Impact resistance 1000 m/s2 300 m/s2 CY 50 M or more at 500 M VDC (Between lead wire and case) Insulation resistance Note 3) MQQ M 1000 VAC for 1 minute (Between lead wire and case) 1500 VAC for 1 minute (1) (Between lead wire and
MTS Type Solid state switch Reed switch 3-wire: 100 A or less, 2-wire: 0.8 mA or less (4) Leakage current None MY Note 2) Operating time 1 ms or less (3) 1.2 ms Impact resistance 1000 m/s2 300 m/s2 CY 50 M or more at 500 M VDC (Between lead wire and case) Insulation resistance Note 3) MG 1000 VAC for 1 minute (Between lead wire and case) 1500 VAC for 1 minute (1) (Between lead wire and case
CL1 Type Solid state switch Reed switch 3-wire: 100 A or less, 2-wire: 0.8 mA or less (4) Leakage current None MLGC Note 2) Operating time 1 ms or less (3) 1.2 ms Impact resistance 1000 m/s2 300 m/s2 CNG 50 M or more at 500 M VDC (Between lead wire and case) Insulation resistance Note 3) MNB 1000 VAC for 1 minute (Between lead wire and case) 1500 VAC for 1 minute (1) (Between lead wire and
MTS Type Solid state switch Reed switch 3-wire: 100 A or less, 2-wire: 0.8 mA or less (4) Leakage current None MY Note 2) Operating time 1 ms or less (3) 1.2 ms Impact resistance 1000 m/s2 300 m/s2 CY 50 M or more at 500 M VDC (Between lead wire and case) Insulation resistance Note 3) MG 1000 VAC for 1 minute (Between lead wire and case) 1500 VAC for 1 minute (1) (Between lead wire and case
MTS Type Solid state switch Reed switch 3-wire: 100 A or less, 2-wire: 0.8 mA or less (4) Leakage current None MY Note 2) Operating time 1 ms or less (3) 1.2 ms Impact resistance 1000 m/s2 300 m/s2 CY 50 M or more at 500 M VDC (Between lead wire and case) Insulation resistance Note 3) MG 1000 VAC for 1 minute (Between lead wire and case) 1500 VAC for 1 minute (1) (Between lead wire and case
MHF Type Solid state switch Reed switch 3-wire: 100 A or less, 2-wire: 0.8 mA or less (4) Leakage current None MHL Note 2) Operating time 1 ms or less (3) 1.2 ms Impact resistance 1000 m/s2 300 m/s2 MHR 50 M or more at 500 M VDC (Between lead wire and case) Insulation resistance Note 3) MHK 1000 VAC for 1 minute (Between lead wire and case) 1500 VAC for 1 minute (1) (Between lead wire and
MHF Type Solid state switch Reed switch 3-wire: 100 A or less, 2-wire: 0.8 mA or less (4) Leakage current None MHL Note 2) Operating time 1 ms or less (3) 1.2 ms Impact resistance 1000 m/s2 300 m/s2 MHR 50 M or more at 500 M VDC (Between lead wire and case) Insulation resistance Note 3) MHK 1000 VAC for 1 minute (Between lead wire and case) 1500 VAC for 1 minute (1) (Between lead wire and
.: 1.4 mm Vibration resistance1 30 m/s2 Without pressure sensor/switch With pressure sensor 20 m/s2 With pressure switch Impact2, 3 resistance 150 m/s2 Without pressure sensor/switch With pressure sensor 100 m/s2 With pressure switch Standards CE marking, RoHS 4 Refer to the Valve assembly on page 32 for the valve model number. 5 ZK2-VAmR: After instantaneous energization of the supply valve
to 500 kPa 50 to 500 kPa A sensor may be unconnected or mis-wired.