Table Accuracy: Basic, Size: 50, Max. Rotation Torque: High Torque, LER10: 0.3; LER30: 1.2; LER50: 10, Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: Robotic Type Cables, Flexible Type, Actuator Cable Length: 3, Controller Type - LEC, JXC: JXC91, EtherNet/IP™ Direct Input Type, I/O Cable Length for LEC: w/o Cable, Controller
Table Accuracy: Basic, Size: 30, Max. Rotation Torque: Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6, Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: Robotic Type Cables, Flexible Type, Actuator Cable Length: 3, Controller Type - LEC, JXC: JXC91, EtherNet/IP™ Direct Input Type, I/O Cable Length for LEC: w/o Cable, Controller
Oscillation Angle A: 310°, Torque (Range)(N⋅m): Less than 1, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Rigidity Accuracy: Standard, Environment, Applications: High-Speed, Valves: Not Provided, Torque(N⋅m): 0.22, Size: 10, Motor cable entry direction: Basic type (entry on the right side), Actuator cable type: Robotic (flexible) cable, Actuator cable length(
Oscillation Angle A: 320°, Torque (Range)(N⋅m): 1 to Less than 3, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Rigidity Accuracy: High Rigidity, High Accuracy, Environment, Applications: High-Speed, Valves: Not Provided, Torque(N⋅m): 1.2, Size: 30, Motor cable entry direction: Basic type (entry on the right side), Actuator cable type: Robotic (flexible) cable
Oscillation Angle A: 320°, Torque (Range)(N⋅m): 6 to Less than 10, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Rigidity Accuracy: High Rigidity, High Accuracy, Environment, Applications: High-Speed, Valves: Not Provided, Torque(N⋅m): 6.6, Size: 50, Motor cable entry direction: Basic type (entry on the right side), Actuator cable type: Robotic (flexible) cable
The LES series electric slide table actuator uses a compactly-integrated, recirculating linear guide for high rigidity and high precision. When the LES is ordered with the controller, initial data of the actuator is preset in the controller allowing start-up in a short time with the in.easy modein.. Two types of built-in motors * are available. The series can be top or bottom mounted. In
0 to 50C Linearity Note 1) 5% F .S. or less 3% F .S. or less Repeatability Note 1) 2% F .S. or less 1% F .S. or less Temperature characteristics 2% F.S. or less (15 to 35C based on 25C), 3% F .S. or less (0 to 50C based on 25C) Pulse output, N channel, open drain, output for display unit PF2W3.
/ 14 to 122F -10 to 50C / 14 to 122F Max Operating 2 Position S & D 20Hz 5Hz OR CONTACT YOUR LOCAL SMC REPRESENTATIVE.
Inlet air temperature 5 to 50C IDF (For IDF100F to 150F, up to 60C is allowed.)
Note 2) Power supply 12 months continuous operation (without back lighting) Battery life 250ms Response speed 2% F.S. or less (Temperature conditions: at 25C) Display accuracy 1% F.S. or less (Temperature conditions: at 25C) Repeatability 3% F.S. or less (0 to 50C, based on 25C) Temperature characteristics M5 x 0.8 Piping port 0 to 50C (with no condensation) Ambient temperature 35 to 85%
Double Max 10ms Max 15ms 3-position Max 20ms Max 25ms Life 200 million cycles or more Ambient and Fluid Temperature ( N o t e 3 ) -10 to +50C (14~122F) -5 to +50C (23~122F) Lubricant ( N o t e 4 ) Not required Not required Manual Override Non-locking, Push Non-locking, Push Protection Dustproof Dustproof ( N o t e 2 ) Calculated on the basis of JIS B 8375-1981 (Supply pressure 0.5 MPa {5.1
0 to 50C Linearity Note 1) 5% F.S. or less 3% F.S. or less 2% F.S. or less 1% F.S. or less Repeatability Note 1) 2% F.S. or less (15 to 35C based on 25C), 3% F.S. or less (0 to 50C based on 25C) Temperature characteristics Pulse output, N channel, open drain, output for display unit PF2W3.
0 to 50C Linearity Note 1) 5% F .S. or less 3% F .S. or less Repeatability Note 1) 2% F .S. or less 1% F .S. or less Temperature characteristics 2% F.S. or less (15 to 35C based on 25C), 3% F .S. or less (0 to 50C based on 25C) Pulse output, N channel, open drain, output for display unit PF2W3.
Model ZR1-FX Vacuum to 0.5 MPa 5 to 50C 30 m PVF 0.1 kg Operating pressure range Operating temperature range Filtration efficiency Element Weight (With bracket) Note) If not operated within the specified range of pressure and temperature, trouble may be caused.
0 to 50C Linearity Note 1) 5% F.S. or less 3% F.S. or less 2% F.S. or less 1% F.S. or less Repeatability Note 1) 2% F.S. or less (15 to 35C based on 25C), 3% F.S. or less (0 to 50C based on 25C) Temperature characteristics Pulse output, N channel, open drain, output for display unit PF2W3.
(23 to 122F) Inlet air temperature Ambient temperature 5 to 50C (23 to 122F) 5 to 50C (23 to 131F) Outlet air atmospheric pressure dew point Inlet air flow rate l/min (ANR) (SCFM) Note 2) Standard performance 25C (68F) 62 (2.2) 125 (4.4) 250 (8.8) 375 (13.2) 625 (22.1) 900 (31.8) 1190 (42.0) 725 (25.6) 31 (1.1) Outlet air flow rate l/min (ANR) (SCFM) Purge air flow rate l/min (ANR) (SCFM
(1) Ambient and fluid temperature 10 to 50C (1) 10 to 50C (1) Maximum operating frequency 20 Hz 5 Hz 20 Hz Individual EXH Pilot valve EXH Common exhaust Not required Lubrication Non-locking push type/Slotted locking type (tool required) as an option Pilot valve manual override 150/30 m/s2 Shock/Vibration resistance (2) Dustproof Enclosure 12, 24 VDC and 100, 110, 200, 220 VAC Coil rated
0 to 50C Accuracy Note 1) 5% F.S. 3% F.S. 1% F.S.
0 to 50C Linearity Note 1) 5% F.S. or less 3% F.S. or less 1% F.S. or less (connected with PF2W33) Repeatability Note 1) 3% F.S. or less 3% F.S. or less (connected with PF2W2) Temperature characteristics 2% F.S. or less (15 to 35C based on 25C), 3% F.S. or less (0 to 50C, based on 25C) Pulse output, N channel, open drain, output for display unit PF2W3.
) 5% F.S. (0 to 50C) 2% F.S. (15 to 35C) 5% F.S. (0 to 50C) (15 to 35C) 0.5% F.S. (0 to 50C) 0.5% F.S. (0 to 50C) 0.5% F.S. (0 to 50C) 0.5% F.S. (0 to 50C) 5% F.S. (0 to 50C) 5% F.S. (0 to 50C) 5% F.S. (0 to 50C) Repeatability 1% F.S.