(-4 to 212F) Ambient temperature Note 1) 10 to 60 (14 to 140F) (with no freezing) 10 to 100C (14 to 212F) Fluid temperature Splash-proof (equivalent to IP65) Enclosure Location without corrosive or explosive gases Environment 0 (with oil pressure) Valve leakage cm3/min Unrestricted Mounting position 24VDC, 12VDC, 100VAC, 110VAC, 200VAC, 220VAC, 230VAC (50/60Hz) 100VAC, 200VAC, 220VAC, 230VAC
Size: 16, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 100mm, Motor Option: C (w/Motor Cover), Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 3 (3m), Controller Type - LEC, JXC: 6P (LECA6, PNP, Step Data Input Type),
Size: 16, Bearing Type: M (Sliding Bearing), Motor Mounting: Top Mounting Type, Motor Type: A (Servo Motor, 24 VDC), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 100mm, Motor Option: C (with Motor Cover), Guide Option: w/o Guide, Actuator Cable Type: R (Robotic Cable - Flexible cable), Actuator Cable Length: 3 (3m), Controller Type for (LEC, JXC): 6P (LECA6, Step Data
Size: 25, Bearing Type: L ( Ball Bushing Bearing), Motor Mounting: Top Mounting Type, Motor Type: Step Motor (Servo/24VDC), Lead: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 100mm, Motor Option: C (with Motor Cover), Guide Option: w/o Guide, Actuator Cable Type: R (Robotic Cable - Flexible cable), Actuator Cable Length: 3 (3m), Controller Type for (LEC, JXC): 6P (LECA6, Step
Size: 25, Bearing Type: L ( Ball Bushing Bearing), Motor Mounting: Top Mounting Type, Motor Type: A (Servo Motor, 24 VDC), Lead: C (Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm), Stroke: 100mm, Motor Option: C (with Motor Cover), Guide Option: w/o Guide, Actuator Cable Type: R (Robotic Cable - Flexible cable), Actuator Cable Length: 3 (3m), Controller Type for (LEC, JXC): 6P (LECA6, Step
Size: 25, Bearing Type: M (Sliding Bearing), Motor Mounting: D (In-line Type), Motor Type: A (Servo Motor, 24 VDC), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm), Stroke: 100mm, Motor Option: C (with Motor Cover), Guide Option: w/o Guide, Actuator Cable Type: R (Robotic Cable - Flexible cable), Actuator Cable Length: 3 (3m), Controller Type for (LEC, JXC): 6P (LECA6, Step Data
Size: 16, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 100mm, Motor Option: w/Motor Cover, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 3m, Controller Type - LEC, JXC: LECA6, PNP, Step Data Input Type, I/O Cable Length for
Size: 25, Bearing Type: Ball Bushing Bearing, Motor Mounting: Top Mounting Type, Motor Type: Step Motor (Servo/24VDC), Lead: Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm, Stroke: 100mm, Motor Option: with Motor Cover, Guide Option: w/o Guide, Actuator Cable Type: Robotic Cable - Flexible cable, Actuator Cable Length: 3m, Controller Type for (LEC, JXC): w/Controller, PNP, I/O Cable Length
Size: 25, Bearing Type: Ball Bushing Bearing, Motor Mounting: Top Mounting Type, Motor Type: Servo Motor, 24 VDC, Lead: Size 16: 2.5mm, Size 25: 3mm, Size 32/40: 4mm, Stroke: 100mm, Motor Option: with Motor Cover, Guide Option: w/o Guide, Actuator Cable Type: Robotic Cable - Flexible cable, Actuator Cable Length: 3m, Controller Type for (LEC, JXC): w/Controller, PNP, I/O Cable Length for
Size: 25, Bearing Type: Sliding Bearing, Motor Mounting: In-line Type, Motor Type: Servo Motor, 24 VDC, Lead: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 100mm, Motor Option: with Motor Cover, Guide Option: w/o Guide, Actuator Cable Type: Robotic Cable - Flexible cable, Actuator Cable Length: 3m, Controller Type for (LEC, JXC): w/Controller, PNP, I/O Cable Length for LEC: 3m,
Size: 16, Bearing Type: Sliding Bearing, Motor Mounting: Top Mounting Type, Motor Type: Servo Motor, 24 VDC, Lead: Size 16: 10mm, Size 25: 12mm, Size 32/40: 16mm, Stroke: 100mm, Motor Option: with Motor Cover, Guide Option: w/o Guide, Actuator Cable Type: Robotic Cable - Flexible cable, Actuator Cable Length: 3m, Controller Type for (LEC, JXC): w/Controller, PNP, I/O Cable Length for LEC:
High purity chemical valve, 3 port, Operating pressure: 0 ~ 0.5 MPa , Fluid temperature: 0 to 100C , Port sizes: 1/4, Threads: Rc, NPT FLUOROPOLYMER VALVES and REG. FLUOROPOLYMER, VALVE. VALVE. FLUOROPOLYMER. 0.22088 lb. 2I.
Although the variation in the operating range differs with the cylinder on which the auto switch is mounted, a temperature change of 100C will roughly result in the maximum of 20% reduction in the overall operation range.
Thread type Nil Rc N NPT* * Semi-standard Suffix Low temperature (30 to 60C) High temperature* (10 to 100C) External parts copper-free Nil T V L V S V ST V V SL V V * With pressure gauge type: Max. 80C.
Finger material Dust cover material DFinger material Action 20Action The packing class has been revised to adopt thermal proof materials for use at high temperature of up to 100C. Possible to select the auto switch mounting side.
MHF Symbol Specifications/Description Heat resistance (100C) Fluororubber seal Without magnet EPDM for seals, Fluorine grease Fluorine grease MHL -X4 -X5 -X50 -X53 -X63 -X79 -X79A -X81A Refer to How to Select the Applicable Model on page 700. Refer to pages 700 and 701 for the details on effective holding force and allowable overhanging distance.
Controller Specifications LC7R-K11A LC7R-K12A Model Regeneration method Heat exchange method based on resistance Regenerative resistance capacity 40W Regenerative operation voltage 180V 380V Regenerative absorption unit Regenerative voltage input mis-wiring protection Over current protection, Overheating protection (Normally closed, Radiator sensor OFF at 100C) Protective circuit To PLC,
Controller Specifications LC7R-K11A LC7R-K12A Model Regeneration method Heat exchange method based on resistance Regenerative resistance capacity 40W Regenerative operation voltage 180V 380V Regenerative absorption unit Regenerative voltage input mis-wiring protection Over current protection, Overheating protection (Normally closed, Radiator sensor OFF at 100C) Protective circuit To PLC,
Controller Specifications LC7R-K11A LC7R-K12A Model Regeneration method Heat exchange method based on resistance Regenerative resistance capacity 40W Regenerative operation voltage 180V 380V Regenerative absorption unit Regenerative voltage input mis-wiring protection Over current protection, Overheating protection (Normally closed, Radiator sensor OFF at 100C) Protective circuit To PLC,
Finger material Dust cover material DFinger material Action 20Action The packing class has been revised to adopt thermal proof materials for use at high temperature of up to 100C. Possible to select the auto switch mounting side.