SMC Corporation of America
Elite Part Number Search
Search Results "LEY25B-150C-S1"

Size: 25, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm, Stroke: 150mm, Motor Option: w/Motor Cover, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Standard Cable, Actuator Cable Length: 3m, Controller Type - LEC, JXC: JXC91, EtherNet/IPâ„¢ Direct Input Type, I/O Cable Length for LEC:

Size: 25, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm, Stroke: 150mm, Motor Option: w/Motor Cover, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Without Cable, Actuator Cable Length: Without Cable, Controller Type - LEC, JXC: LECP1, PNP, Programless Type, I/O Cable Length for LEC:

Size: 25, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm, Stroke: 150mm, Motor Option: w/Motor Cover, Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 1.5m, Controller Type - LEC, JXC: LECA6, NPN, Step Data Input Type, I/O Cable Length for LEC

Size: 25, Motor Mounting Position: Top, Motor: Step Motor (Servo 24 VDC), Lead Screw: B (Size 16: 5mm, Size 25: 6mm, Size 32/40: 8mm), Stroke: 150mm, Motor Option: C (w/Motor Cover), Rod End Thread: Female, Mounting: Both Ends Tapped (Standard), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 8 (8m), Controller Type - LEC, JXC: CP1 (JXCP1, PROFINET), I/O Cable Length for

-XAl Change of rod end shape -XB6 Heat resistant cylinder (10 to 150C) * Not available with switch & with air cushion VMounted on the product. vPlease order separately.

Residence time of water at 20C is 5.5 x 10-6 sec, whereas at 150C it is 2.8 x 10-8 sec, or 200 times shorter. As an example, it took 800 minutes to evacuate moist air from a 150mm x 500mm P/A test chamber to 10-9Torr. The same process took only 4 minutes with dry (20ppb) nitrogen.

Residence time of water at 20C is 5.5 x 10-6 sec, whereas at 150C it is 2.8 x 10-8 sec, or 200 times shorter. As an example, it took 800 minutes to evacuate moist air from a 150mm x 500mm SMC test chamber to 10-9Torr. The same process took only 4 minutes with dry (20ppb) nitrogen.

Symbol 1 Heat Resistant Cylinder (10 to 150C) -XB6 Air cylinder which changed the seal material and grease, so that it could be used even at higher temperature up to 150 from 10C.

-XAl Change of rod end shape -XB6 Heat resistant cylinder (10 to 150C) -XB7 Cold resistant cylinder (40 to 70C)*1 Mounting Brackets/Part No.

Bore size (mm) Effective thread length Width across flats A D H K MM W ZZ 40 50 63 80 100 32 37 37 37 47 18 22 22 26 31 35 40 40 40 50 20 25 25 30 36 58 71 71 72 85 7 11 11 11 15 M18 x 1.5 9 9 9 0 0 153 172 183 205 228 M22 x 1.5 M22 x 1.5 M26 x 1.5 A B M30 x 1.5 With heavy duty scraper -XC4 Heat resistant (150C) -XB6 4 2 The cylinder seals are changed to a heat resistance (to 150C) material

MB XB6 With heavy duty scraper Specifications Heat resistant cylinder (150C) Specifications Action Cushion Wiper ring Double acting, Single Double rod Air cushion/Rubber bumper SCB scraper Double acting, Single/Double rod 10C to 150C Unavailable for mounting Air cushion Fluorine rubber Heat resistant grease Action Ambient temp.

, Non-rotating rod Series CUK Long stroke, Non-rotating rod Series CUK Double acting Single rod 39 With air cushion Series CU-A With air cushion Series CU-A 20, 25, 32 Double acting Single rod 46 For vacuum Series ZCUK For vacuum Series ZCUK 10, 16, 20, 25, 32 Double acting Single rod 55 Related Products Made to Order P . 4, 23, 37 Copper/Fluorine-free: Series 20-XB6 : Heat resistant (150C

(Max. 150C) Heat resistant Sensor section: Rail Amplifier section: DIN rail Grommet D-F7NJL Wide range detection type Wide range detection D-G5NBL 8-30-50 Band Grommet This auto switch can be mounted by tie-rod with using mounting bracket. For details, refer to page 8-30-62.

) XB6 2 5 The cylinder seals are changed to a heat resistant (to 150C) material, for use under severe conditions which exceed the standard specifications of 10C to +70C.

(Max. 150C) Heat resistant Sensor section: Rail Amplifier section: DIN rail Grommet D-F7NJL Wide range detection type Wide range detection D-G5NBL 8-30-50 Band Grommet This auto switch can be mounted by tie-rod with using mounting bracket. For details, refer to page 8-30-62.

CDRBU2W10, 15-S CDRBU2W20, 30-S CRB2 CRBU2 CRB1 2 x S2 2 x S1 2 x S1 MSU 2 x S2 CRJ Rotary actuator CRA1 CRQ2 2 x S1 2 x S1 2 x S1 2 x S1 Rotary actuator MSQ (34.5: Connector type) MSZ A port B port CRQ2X MSQX 2 x R A port B port 2 x R MRQ 1 Auto switch Auto switch 2 5 20.5 (26.5: Connector type) 1.

S2 R1 R2 SG FG 24 V 0 V S1 S2 SG 24 V 0 V S1 S2 R1 R2 SG FG 24 V 0 V S1 S2 R1 R2 SG FG 24 V 0 V Ground either the reception side or the transmission side of the shielding wire shield.

Symbol -XB6 Heat Resistant Cylinder (10 to 150C) 3 Air cylinder which changed the seal material and grease, so that it could be used even at higher temperature up to 150 from 10C.

Air-hydro type 20 to 63 V V 10-, 11Clean series 20 to 100 V V V V v Note 1) Note 1) 25ANote 9) Copper (Cu) and Zinc (Zn)-free Note 15) 20 to 100 V V v v v v v v 20Note 9) Copper Note 8) and Fluorine-free 20 to 100 V V V V v V v V CG1lR V Water resistant 32 to 100 V V V V v CG1lM Cylinder with stable lubrication function (Lube-retainer) 20 to 100 V v v v v XB6 Heat resistant cylinder (10 to 150C

Sleeveless 65 to 260C (Swivel elbow: 5 to 150C) Superior tube mounting Applicable tubing material FEP PFA Modified PTFE 2-layer soft fluoropolymer Nylon Soft nylon Polyolefin Polyurethane Soft polyurethane Hard polyurethane Soft polyolefin Sleeve Union nut Light tightening torque Comparison with current model 60% down Approx.