JX C 9 1 () LEFS16B-100B-S1C917 [LEFS16B-100] 9 EtherNet/IP 1 1 DC24V 7 8 DIN <> LECPMJ SVRE X1.5 -7- 2.3 *1 EtherNet/IP PLC P1P2 P5062-5 *1 () LE-CP-() LE-CP---S () LE-CP-* ENC *2 SI MOT 120.3 120.3 mm mm 200 200 mm/s mm/s 100 500 100 500 1 1 200 1000 200 1000 2 2 50 200 50 200 3 3 PWR DC24V USB (A-miniB type) () JXC-CPW <> ( USB ) LEC-W2 (3m) AWG20(0.5mm
Keep this operation manual accessible for reference. 5 No.JXC-OMW1019-A 2.2 How to Order The part number construction for this product is as follows: With JOG input terminal, WAREA output function (Number of step data: 32 points) U Controller UCompatible Electric actuator model Step motor(Servo / 24VDC) P6 Stroke example: For LEFS25B-100B-S36N1, specify LEFS25B-100.
machines (Part 1: General requirements) ISO 10218-1992: Manipulating industrial robots -Safety JIS B 8370: JIS B 8361: JIS B 9960-1: -1 ) JIS B 8433-1993: *2) (1) (2) (3) 1. 2. 3. (4) 1. 2. 3. 4. 4 - LECPMJ / 1 / (1)1 1.5 *3) (2) (3) *3) 1 5 - 2. 2.1 CC-Link CC-Link CC-Link CC-Link CC-Link CC-Link 64 / CC-Link DRIVE INP 1 2 CC-Link CC-Link * 6 - 2.2 LE C P MJ (LE ) LEFS16B-100B-S1MJS
Allowable theoretical strokes (mm) Mounting type Accessories Pressure Bore (mm) [MPa] 32 40 50 63 80 100b L F (front) G (rear) 0.2 680 980 1220 1410 0.3 540 1020 790 980 1140 L 0.4 460 700 880 680 840 980 0.5 410 630 780 610 750 880 F (front) 0.6 370 580 710 550 680 800 0.7 340 520 650 500 620 730 0.8 310 480 600 460 580 680 0.9 290 450 570 430 540 630 1 270 420 530 400 510 590 0.2 580
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
Rated Flow Range: 2 (2.5 to 100 L/min), Output Specifications: K (OUT: Analog 4 to 20 mA; Remote Type Sensor Unit), Port Size: 6 (3/4; Applicable to LFE2), Thread: Rc, Option: 2 (Lead Wire w/M12 Connector; Bracket; L/min Unit Specification), Insulation Type: None, Piping Port is connected to Negative Ground of the Power Supply), Piping Connection: X8 (Stainless Steel 304)
Rated Flow Range: 3 (5 to 200 L/min), Output Specifications: K (OUT: Analog 4 to 20 mA; Remote Type Sensor Unit), Port Size: 8 (1; Applicable to LFE3), Thread: N (NPT), Option: Lead Wire w/M12 Connector; L/min Unit Specification, Insulation Type: None, Piping Port is connected to Negative Ground of the Power Supply), Piping Connection: X8 (Stainless Steel 304)
Rated Flow Range: 1 (0.5 to 20 L/min), Output Specifications: J (OUT: Analog 1 to 5 V; Remote Type Sensor Unit), Port Size: 4 (1/2; Applicable to LFE1), Thread: Rc, Option: 2 (Lead Wire w/M12 Connector; Bracket; L/min Unit Specification), Insulation Type: None, Piping Port is connected to Negative Ground of the Power Supply), Piping Connection: X8 (Stainless Steel 304)
Rated Flow Range: 3 (5 to 200 L/min), Output Specifications: K (OUT: Analog 4 to 20 mA; Remote Type Sensor Unit), Port Size: 8 (1; Applicable to LFE3), Thread: N (NPT), Option: 2 (Lead Wire w/M12 Connector; Bracket; L/min Unit Specification), Insulation Type: Z (Piping Port is Insulated with the Power Supply), Piping Connection: X8 (Stainless Steel 304)
Connection, IN OUT: 0 (Rc), Port Size: 02 (Rc, NPT, TSJ, UOJ; 1/4), Made to Order: X8 (Aluminum Case)
AXIS AXIS AXIS 1 2 3 4 PLC READY signal ON PLC CPU preparation Y0 QD75 READY signal ON QD75MH preparation X0 All axis servo ON ON All axis servo ON Y1 Interface signal Synchronization flag(Note1) ON QD75MH buffer memory Accessible X1 Axis stop signal OFF Axis stop signal is OFF Y4 Y5 Y6 Y7 M code ON signal OFF M code ON signal is OFF X4 X5 X6 X7 Error detection signal OFF There is no error X8
Piping connections come in C37 brass as standard, while the -X8 option offers 304 stainless steel. LFE is IP65 rated, and CE and RoHS compliant. Flow ranges (lpm): 0.5-20, 2.5-100, 5-200; Port Sizes (Rc, NPT, G): 3/8, 1/2, 3/4, 1 (flow range dependent); Temperature rating: 0-85°C; Output options: 1-5v, 4-20mA; Accuracy: ±4% F.S.; Repeatability: ±2% F.S.
The X8 option is a dust-proof and water-jet-proof specification equivalent to IP67. This spec is achieved with the addition of several unique features above the standard LEY. The motor is sealed within an aluminum cover, fitted with M-type metal cable connectors. The rod passes through a scraper and employs a lubrication retainer to prevent oil film washout.
The X8 option is a dust-proof and water-jet-proof specification equivalent to IP67. This spec is achieved with the addition of several unique features above the standard LEY. The motor is sealed within an aluminum cover, fitted with M-type metal cable connectors. The rod passes through a scraper and employs a lubrication retainer to prevent oil film washout.
The X8 option is a dust-proof and water-jet-proof specification equivalent to IP67. This spec is achieved with the addition of several unique features above the standard LEY. The motor is sealed within an aluminum cover, fitted with M-type metal cable connectors. The rod passes through a scraper and employs a lubrication retainer to prevent oil film washout.
Piping connections are C37 brass as standard, while the -X8 option offers 304 stainless steel. LFE is IP65 rated, and CE and RoHS compliant. Flow ranges (lpm): 0.5-20, 2.5-100, 5-200; Port sizes (Rc, NPT, G): 3/8, 1/2, 3/4, 1, (flow range dependent); Temperature rating: 0-85°C; Output options: NPN/PNP, 1-5V, 4-20mA; Accuracy: ±4% F.S. ; Repeatability: ±2% F.S.
Piping connections come in C37 brass as standard, while the -X8 option offers 304 stainless steel. LFE is IP65 rated, and CE and RoHS compliant. Flow ranges (lpm): 0.5-20, 2.5-100, 5-200; Port Sizes (Rc, NPT, G): 3/8, 1/2, 3/4, 1 (flow range dependent); Temperature rating: 0-85°C; Output options: 1-5v, 4-20mA; Accuracy: ±4% F.S.; Repeatability: ±2% F.S.
The X8 option is a dust-proof and water-jet-proof specification equivalent to IP67. This spec is achieved with the addition of several unique features above the standard LEY. The motor is sealed within an aluminum cover, fitted with M-type metal cable connectors. The rod passes through a scraper and employs a lubrication retainer to prevent oil film washout.
Piping connections are C37 brass as standard, while the -X8 option offers 304 stainless steel. LFE is IP65 rated, and CE and RoHS compliant. Flow ranges (lpm): 0.5-20, 2.5-100, 5-200; Port sizes (Rc, NPT, G): 3/8, 1/2, 3/4, 1, (flow range dependent); Temperature rating: 0-85°C; Output options: NPN/PNP, 1-5V, 4-20mA; Accuracy: ±4% F.S. ; Repeatability: ±2% F.S.