.cat-top-box{display: inline-flex;} .cat-image-holder{ width: 40%; } .cat-image-holder img{ width: 100%; } .cat-description-holder{ width: 50%; } table.specifications-table { border: 2px solid #B6B6B6; width: 100%; margin:30px 0; } .specifications-table td { padding: 8px 4px; margin: 3px; border: 1px solid #b6b6b6; text-align: center; } .specifications-table
NIL IDF 100 F 30 NIL C 1 K 2 Size P 3 Air compressor size Note) 100kW 125kW 150kW Note) The value is referential. Confirm the capability of the compressor used.
Also, when the sealant tape is used, leave approximately 1 thread ridge exposed at the end of the threads. 100 2d D L 1 = Mandrel 5 - 2. Specific Product Precautions (2) (3) Check the model, type and size before installation.
Move the actuator from the origin to a point 100 mm away at 100 mm/s. (Step Data No.1 is used for this operation). From the 100 mm point, the actuator must start a pushing operation of 10 mm/s speed and 50% or less force. (the pushing distance is up to 5 mm).
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Enclosure: IP65
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Enclosure: IP65
Size: 25, Motor Mounting: Top Mounting Position, Motor Type: Step Motor, Servo/24 VDC, Lead: B (LEY25, 6; LEY32, 8), Stroke: 400mm, Motor: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Actuator Cable Length: C (20m), Controller Type (LEC, JXC): w/o Controller, I/O Cable Length for LEC: w/o Cable, Controller Mounting: Screw Mounting, Communication Plug
Size: 32, Motor Mounting: Top Mounting Position, Motor Type: Step Motor, Servo/24 VDC, Lead: B (LEY25, 6; LEY32, 8), Stroke: 250mm, Motor: w/o Lock, Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut Included), Mounting: Ends Tapped (Standard), Actuator Cable Length: C (20m), Controller Type (LEC, JXC): w/o Controller, I/O Cable Length for LEC: w/o Cable, Controller Mounting: Screw Mounting
Size: 32, Motor Mounting: D (In-line Type), Motor Type: Step Motor, Servo/24 VDC, Lead: B (LEY25, 6; LEY32, 8), Stroke: 200mm, Motor: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Actuator Cable Length: C (20m), Controller Type (LEC, JXC): w/o Controller, I/O Cable Length for LEC: w/o Cable, Controller Mounting: Screw Mounting, Communication Plug Connector
Size: 25, Motor Mounting: Top Mounting Position, Motor Type: Step Motor, Servo/24 VDC, Lead: C (LEY25, 3; LEY32, 4), Stroke: 350mm, Motor: B (w/Lock), Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut Included), Mounting: G (Head Flange), Actuator Cable Length: C (20m), Controller Type (LEC, JXC): w/o Controller, I/O Cable Length for LEC: w/o Cable, Controller Mounting: Screw Mounting
Size: 32, Motor Mounting: Top Mounting Position, Motor Type: Step Motor, Servo/24 VDC, Lead: B (LEY25, 6; LEY32, 8), Stroke: 400mm, Motor: w/o Lock, Rod End Thread: M (Rod End Male Thread, 1 Rod End Nut Included), Mounting: Ends Tapped (Standard), Actuator Cable Length: C (20m), Controller Type (LEC, JXC): w/o Controller, I/O Cable Length for LEC: w/o Cable, Controller Mounting: Screw Mounting
Size: 25, Motor Mounting: Top Mounting Position, Motor Type: Step Motor, Servo/24 VDC, Lead: LEY25, 6; LEY32, 8, Stroke: 400mm, Motor: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Actuator Cable Length: 20m, Controller Type (LEC, JXC): w/o Controller, I/O Cable Length for LEC: w/o Cable, Controller Mounting: Screw Mounting, Communication Plug Connector
Size: 32, Motor Mounting: Top Mounting Position, Motor Type: Step Motor, Servo/24 VDC, Lead: LEY25, 6; LEY32, 8, Stroke: 250mm, Motor: w/o Lock, Rod End Thread: Rod End Male Thread, 1 Rod End Nut Included, Mounting: Ends Tapped (Standard), Actuator Cable Length: 20m, Controller Type (LEC, JXC): w/o Controller, I/O Cable Length for LEC: w/o Cable, Controller Mounting: Screw Mounting, Communication
Size: 32, Motor Mounting: In-line Type, Motor Type: Step Motor, Servo/24 VDC, Lead: LEY25, 6; LEY32, 8, Stroke: 200mm, Motor: w/o Lock, Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Actuator Cable Length: 20m, Controller Type (LEC, JXC): w/o Controller, I/O Cable Length for LEC: w/o Cable, Controller Mounting: Screw Mounting, Communication Plug Connector or I/O
Size: 25, Motor Mounting: Top Mounting Position, Motor Type: Step Motor, Servo/24 VDC, Lead: LEY25, 3; LEY32, 4, Stroke: 350mm, Motor: w/Lock, Rod End Thread: Rod End Male Thread, 1 Rod End Nut Included, Mounting: Head Flange, Actuator Cable Length: 20m, Controller Type (LEC, JXC): w/o Controller, I/O Cable Length for LEC: w/o Cable, Controller Mounting: Screw Mounting, Communication Plug
Size: 32, Motor Mounting: Top Mounting Position, Motor Type: Step Motor, Servo/24 VDC, Lead: LEY25, 6; LEY32, 8, Stroke: 400mm, Motor: w/o Lock, Rod End Thread: Rod End Male Thread, 1 Rod End Nut Included, Mounting: Ends Tapped (Standard), Actuator Cable Length: 20m, Controller Type (LEC, JXC): w/o Controller, I/O Cable Length for LEC: w/o Cable, Controller Mounting: Screw Mounting, Communication
Size: 25, Motor Mounting: Top Mounting Position, Motor Type: Step Motor, Servo/24 VDC, Lead: A (LEY25, 12; LEY32, 16), Stroke: 300mm, Motor: B (w/Lock), Rod End Thread: Rod End Female Thread, Mounting: Ends Tapped (Standard), Actuator Cable Length: C (20m), Controller Type (LEC, JXC): w/o Controller, I/O Cable Length for LEC: w/o Cable, Controller Mounting: Screw Mounting, Communication Plug
Move mm/s mm mm/s2 mm/s2 mm/s mm mm mm 0 ABS 100 20.00 1000 1000 0 0 0 100 18.00 22.50 0.5 1 ABS 50 10.00 1000 1000 70 60 5 100 6.0 12.0 1.5 63 ABS 20 5.00 500 500 0 0 0 100 3.0 8.0 1.2 Caution Writing of the step data should be performed while the electric actuator is stopped 59 - Details of step data Setting name Range Description No. 0 to 63 Number of the step data.
The guideline is 80% or less. 0 to 100 % 12 Effective load ratio The continuous effective load current is displayed. The effective value is displayed relative to the rated current of 100%. 0 to 300 % 13 Peak load ratio The maximum torque is displayed.
The guideline is 80% or less. 0 to 100 % 12 Effective load ratio The continuous effective load current is displayed. The effective value is displayed relative to the rated current of 100%. 0 to 300 % 13 Peak load ratio The maximum torque is displayed.