SMC Corporation of America
Elite Part Number Search
Search Results "MWBF40-UT-850"

Applicable strokes: 150, 250, 350, 450, 550, 650, 750, 850, 950 Example) LJ1S1011SC-150-F2-X2 Allowable Moment (Nm) Allowable static moment Allowable dynamic moment Model Mounting orientation Load movement direction Pitching Rolling Yawing 1.3 1.5 0.7 LJ1S10 30 a = 500 Horizontal/Lateral Horizontal/Lateral Lateral Horizontal a = 1000 a L1 (mm) 20 a = 2000 Pitching Mep m m : Transfer load

), Thin flat with ribs (CT) Thin flat Thin flat with ribs ZP 10 UT N 7 7 Pad diameter ZX Material 12 12 Y Y 10 N 10 NBR ZR 13 S 13 Silicon rubber A A 16 U 16 Urethane rubber B B ZM F Fluoro rubber GN ZPUT ZPCT Conductive NBR Pad type ZH GS Conductive silicon rubber UT Thin flat Dimensions (mm) Dimensions (mm) CT Thin flat with ribs ZU Courtesy of Steven Engineering, Inc.-230 Ryan Way, South

), Thin flat with ribs (CT) Thin flat Thin flat with ribs ZP 10 UT N 7 7 Pad diameter ZX Material 12 12 Y Y 10 N 10 NBR ZR 13 S 13 Silicon rubber A A 16 U 16 Urethane rubber B B ZM F Fluoro rubber GN ZPUT ZPCT Conductive NBR Pad type ZH GS Conductive silicon rubber UT Thin flat Dimensions (mm) Dimensions (mm) CT Thin flat with ribs ZU Courtesy of Steven Engineering, Inc.-230 Ryan Way, South

Com m uni cat i on dat a al l ocat i on Set t arget val ue Resol ut i on : 12bi t ( 100% F. S. ) , O ccupi ed byt e : 2 Byt e Target val ue ( 0 area) 12bi t 0 0 0 0 Target value(Lower 12 bits) * b0 b15 b11 Put 0 i n upper 4 bi t s ( N ot e) M oni t or t he out put pressure. Resol ut i on : 12bi t ( 100% F.

O ut put area I nput area W o rd d ata area In p u t w o rd d ata Rem arks W o rd d ata area O u tp u t w o rd d ata Rem arks RW w 0 b15, b14, b1, b0 b 1 1b 0100% F.S. RW r0 b15, b14, b1, b0 b 1 1b 0100% F.S. RW w 1 U nused RW r1 U nused RW w 2 U nused RW r2 U nused RW w 3 U nused RW r3 U nused O ut put dat a occupi es 4 w ords, but uses onl y t he 1st w ord act ual l y.

Pdrt Numlel llodel (Rel) A I D T H I K UFfll0xl ut 6363109 0 tli0. l l'l( E ) M l O x l r,50 .41 .24 .25 1.000.98 0.49 IVA.20 N/A Ut l2rl ut5588189 0H,r. r 5 (BI M l 2 x l t.50 .47 .24 .15 1.000.980.49 N/A.20 N/A UlV2.20 ut3935095 ([n)0EM.25(B) rr.?0 uNt 1.50 .56.28 -t) t.001.00 0.50 fl/A .?0 il/a UtjA6.

850 6 9 9 9 12 12 12 16 16 460 665 693 693 1162 1162 1162 1416 1416 19 19 19 19 19 19 19 27 27 80 M16 x l 250 M16 x l 250 M16 x l 250 M16 x l 300 M16 x l 300 M16 x l 300 M16 x l 500 M24 x l 500 M24 x l 500 AT6C AT11C AT22C AT37C AT55C AT75C AT125C AT150C AT220C 1 2 Rc 1/2 Rc 3/4 Rc 1 Rc 1 Rc 1 1/4 Rc 1 1/4 Rc 2 Rc 2 Rc 2 Rc 110 110 110 180 180 180 260 260 Rc 3 4 Rc 1 1 2 1 2 Rc 1 2B (JIS

10 to 300 Speed*1 [mm/s] 501 to 600 30 to 1200 20 to 850 10 to 300 Actuator specifications Parallel Stroke range Up to 500 20 to 900 12 to 600 6 to 300 24 to 800 16 to 650 8 to 325 30 to 750 20 to 550 10 to 300 501 to 600 30 to 750 20 to 550 10 to 300 Max. acceleration/deceleration [mm/s2] 3000 Positioning repeatability [mm] 0.01 (Lead H: 0.02) Lost motion [mm]*2 0.05 Lead [mm] 20 12 6 24

/1070 850/1070 1450/1890 2000/2500 Single-phase 200 V 4.3/4.7 4.3/4.7 Operating current [A] Refrigerant R407C (HFC) IDF F 50/60 Hz *6 Three-phase 200 V 3.3/3.5 3.3/3.5 6.0/6.6 7.2/8.0 Applicable earth leakage breaker capacity *7 [A] (Sensitivity of leak current of 30 mA) 10 (200 VAC) 15 (200 VAC) Condenser Air-cooled Refrigerant R407C (HFC) Refrigerant charge [kg] Single-phase 200 V 0.42

W: 800 [W] Power supply output VI: 1.0 [kVA] W Efficiency Q = P = Q = P = V x I x Power factor In this example, using an efficiency of 0.7: In this example, using a power factor of 0.85: 800 0.7 = 1.0 [kVA] x 0.85 = 0.85 [kW] = 850 [W] = = 1143 [W] Cooling capacity = Considering a safety factor of 20%, Cooling capacity = Considering a safety factor of 20%, 850 [W] x 1.2 = 1020 [W] 1143 [W

Power supply output VI: 1.0 [kVA] Q = P = V x I x Power factor In this example, using a power factor of 0.85: = 1.0 [kVA] x 0.85 = 0.85 [kW] = 850 [W] Cooling capacity = Considering a safety factor of 20%, 850 [W] x 1.2 = 1020 [W] HRZ W Efficiency Q = P = HRZD In this example, using an efficiency of 0.7: HRW 800 0.7 = = 1143 [W] HECR Cooling capacity = Considering a safety factor of 20%,

Nil Without cable H Without cable (Connector only) 1 1.5 Applicable Stroke Table : Standard Stroke [mm] Manufacturable 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 stroke range Model [mm] LEFS25 50 to 600 LEFS32 50 to 800 LEFS40 150 to 1000 * When the driver type is selected, the cable is included. Select cable type and cable length.

inch) 138 mm (5.4 inch) 8x12 mm (0.5 inch) 617 mm (24.3 inch) (715 mm) (28.1 inch) 627 mm (24.7 inch) 48 mm (1.9 inch) 43 mm (1.7 inch) (954 mm) (37.6 inch) 19 mm (0.7 inch) 984 mm (38.7 inch) Dimensions for the positions of the anchor bolts (View a-a) 8.2 Dimensions HRSH Series 8-8 HRX-OM-Q026 Chapter 8 Documents 8.2.3 HRSH250/300-A-20-, HRSH250/300-A-40HRSH250-A-20-B1, HRSH250-A-20-S 850

DC500V 50M 690g 13 3-3 7.6 R03-R8M 205m 50cm 14.5mT DC10.826.4V1 50mAMAX. 0.1mm/ 02mm 1 MAX.DC30V50mA) A /B 500mm/s AC500V1 (12E ) DC500V50M (12E ) 33.3Hz6.8G XY 2 Z 4 JIS D1061 30G XYZ 3 IP65 () 5m10m15m20m R03-R8F 1CEU2 14 4. 4-1 () CE2 B 40 100 J 2 B 1 L n F G C D () T J 50 50mm K 63 63mm 80 80mm N 100 100mm R H Z mm mm mm 40 25~850

Weight Model LEFS40 Stroke(mm) 150 200 250 300 350 400 450 500 550 600 Weight(kg) 5.37 5.65 5.93 6.21 6.49 6.77 7.15 7.33 7.61 7.89 0.53 Additional weight for lock(kg) Model LEFS40 Stroke(mm) 650 700 750 800 850 900 950 1000 1100 1200 Weight(kg) 8.17 8.45 8.73 9.01 9.29 9.57 9.85 10.13 10.69 11.25 0.53 Additional weight for lock(kg) 11 - LECP6

5.80 6.00 6.20 6.40 6.60 6.80 7.00 7.20 S7 3.34 3.54 3.74 3.94 4.14 4.34 4.54 4.74 4.94 5.14 5.34 5.54 5.74 5.94 6.14 6.34 6.54 6.74 6.94 7.14 Motor type T7 3.31 3.51 3.71 3.91 4.11 4.31 4.51 4.71 4.91 5.11 5.31 5.51 5.71 5.91 6.11 6.31 6.51 6.71 6.91 7.11 Additional weight for lock[kg] S3:0.4/S7:0.7/T7:0.5 Series LEFS40 Stroke[mm] 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850

For AFF2C to 22C, 37B, 75B, AM150C to 550C, 650, and 850 The pressure drop reaches 0.1 MPa or two years have elapsed after operation start, whichever comes earlier. [The pressure drop can be checked using the equipment with the element service indicator (-T) or differential pressure gauge (made to order specifications).] b.

For AFF2C to 22C, 37B, 75B, AM150C to 550C, 650, and 850 The pressure drop reaches 0.1 MPa or two years have elapsed after operation start, whichever comes earlier. [The pressure drop can be checked using the equipment with the element service indicator (-T) or differential pressure gauge (made to order specifications).] b.

Max. operating frequency Not required Lubrication Double acting Action Solid state auto switch (3-wire, 2-wire) Auto switch (Option) Note) Note) Refer to pages 797 to 850 for further information on auto switches.