(mm) 8 2 2.5 4 5 6.5 M Black (B) H/DL L/LL Air Fluid KC 20C 0.9 Max. operating pressure (MPa) 40C 0.7 KK Recommended fittings Antistatic one-touch fittings: KA series Miniature fittings: M and MS series Note) Minimum bending radius (mm) 10 15 20 27 35 10 KK130 0 to 40C Operating temperature Max.
Max. ambient temperature 40C P. 12 IDF1E to 11E IDU3E to 6E Bypass piping set Max. operating pressure 1.0 MPa Max. operating temperature 60C Easy bypass piping (connect this set to the air dryer), allowing substantial reduction in the installation time.
-XB7 Cold resistant (40C) Applicable Model Standard, Double acting, Single rod C(D)U XB7 Enter the applicable model number.
Operating Pressure Air 145psi (1.0MPa) Size At 75F (24C) At 200F (93C) 3/8 1/4 1/2 5/32 5/8 3/4 1400psi 1200psi 950psi 1200psi 900psi 800psi Proof Pressure 450psi (3.1MPa) Recommended Fluid and Ambient Temperature* -40F to 140F (-40C to 60C) 7 Ncm/min. or less Leak Rate at -40F (-40C) Thread Portion Nut ANSI/ASME B1.20.1, 1983, R1992 Thread JIS B 0208 (Unified fine thread), ISO 263 Thread
0.99 4.18 x 103 0.99 1 x 103 40C 1.01 3.92 x 103 1.01 0.94 x 103 Note) The above shown are reference values.
Nylon, Soft nylon, Polyurethane , , , , 5 32 1 4 5 16 3 8 1 2 T VMG KM11 Specifications Fluid Air Water Note) Model KM11 KM12 KM12 1.0 MPa Maximum operating pressure Proof pressure Ambient and fluid temperature 3.0 MPa 5 to 60C (Water: 0 to 40C) (No freezing) ANSI/ASMEB1.20. 1-1983 (NPT thread) Thread Note) Applicable for general industrial water.
OUT Standard specification Option Note) Water (Standard, up to 40C) Air (Standard, Dry) Turbine oil Vacuum (up to 1.3 x102 Pa) Carbon dioxide (CO2), Nitrogen gas (N2) Vacuum (up to 1.3 x101 Pa) (V, M) Non-leak (106 Pa m3/s or less) (V, M) IN N.O.
with the product as accessories. 5 Bernoulli Gripper ZNC Series Specifications Model ZNC20 ZNC30 ZNC40 ZNC60 ZNC80 Lifting force [N]*1, *3 5.2 10.7 13.8 28.3 65 Air consumption [L/min] (ANR)*2, *3 131 138 182 182 255 Type Bernoulli Fluid Air Operating pressure 0.1 to 0.5 MPa Proof pressure 0.75 MPa Aluminum 5 to 80C (0 to 50C) Ambient and operating temperatures*4 Body material Resin 5 to 40C
Arbitrary address Vendor ID 7 h (SMC Corporation) Product type 2 Bh (Generic Device) Product code DEh Serial communication USB2.0 (Full Speed 12 Mbps) Memory Flash-ROM LED indicator PWR, RUN, USB, ALM, NS, MS, L/A, 100 Lock control Forced-lock release terminal *4 Communication Cable length Actuator cable: 20 m or less Cooling system Natural air cooling Operating temperature range 0C to 40C
or less Isobutyl alcohol Note 1), 2) Temperature 40C or less Isopropyl alcohol Temperature 40C or less Note 1), 2) Hydrochloric acid Concentration 30% or less Note 2) Hydrogen peroxide Concentration 5% or less, Temperature 50C or less Nitric acid (except fuming nitric acid) Concentration 10% or less, Temperature 40C or less Note 2) Deionized water Sodium hydroxide (Caustic soda) Concentration
Fluid temperature and ambient temperature ranges are; 0 to 40C for ionizer, 0 to 50C for feedback sensor and auto balance sensor (high accuracy type), 0 to 40C for AC adapter, and 0 to 45C for remote controller. Do not use the sensor in locations where the temperature may change suddenly even if the ambient temperature range is within the specified limits, resulting in condensation. 2.
Time A
Compatible with a low dew point (40C). Using a vacuum port for vacuum suction enables reducing more dust particles than 90series.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Motor capacity 200W 100W 200W 100W 5 to 40C 5 to 50C 5 to 40C 5 to 50C Operating temperature range Electric power 640VA 300VA 640VA 300VA Control system AC software servo/PTP control Position detection system Incremental encoder Home position return direction
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Motor capacity 200W 100W 200W 100W 5 to 40C 5 to 50C 5 to 40C 5 to 50C Operating temperature range Electric power 640VA 300VA 640VA 300VA Control system AC software servo/PTP control Position detection system Incremental encoder Home position return direction
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Motor capacity 200W 100W 200W 100W 5 to 40C 5 to 50C 5 to 40C 5 to 50C Operating temperature range Electric power 640VA 300VA 640VA 300VA Control system AC software servo/PTP control Position detection system Incremental encoder Home position return direction
5 to 40C 5 to 40C 5 to 40C Electric energy 180VA 640VA 300VA 300VA 640VA 100VA 300VA 640VA 640VA 300VA 180VA 300VA Control system AC software servo/PTP control Position detection system Incremental encoder Home position return function Maximum positioning point setting With magnet switch as adjacent switch, and encoder Z phase signal as home position signal.
Fluid Set pressure range Hysteresis ZY Air 0 to 101 kPa 3% Full span or less 3% Full span (5 to 40C) 5% Full span (0 to 60C) 12 to 24 VDC (Ripple 10% or less) M5 x 0.8 Note) If not operated within the specified range of pressure and temperature, trouble may be caused. ZQ 1% Full span Accuracy ZF Voltage Port size ZP ZCU AMJ Misc.
The base oil of grease in the cylinder may seep out of the tube, cover, or crimped part depending on the operating conditions (ambient temperature 40C or more, pressurized condition, low frequency operation). CS1 Releasing the Lock Warning CS2 1.
Allowable voltage range [V] Rated voltage [A] Single phase 200 to 230 VAC (50/60 Hz) Single phase 170 to 253 VAC Single phase 100 to 120 VAC (50/60 Hz) Single phase 85 to 132 VAC 1.5 24 VDC 21.6 to 26.4 VDC 0.5 6 inputs 4 outputs 1 M (when differential receiver), 200 k (when open collector) 0 to 65535 (Pulse command unit) 3 rotations Parameter setting USB communication 32 to 104F (0 to 40C