Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Solid state auto switches marked with are produced upon receipt of order. Bore sizes 32 to 63 are available for the D-P3DWA. Since there are other applicable auto switches than listed, refer to page 515 for details.
V v v Diagnostic indication (2-color indicator) Relay, PLC 24 V Grommet Yes 2-wire 12 V M9BWV M9BW V V V v v 3-wire (NPN) 5 V, 12 V M9NAV2 M9NA2 v v V v v IC circuit 3-wire (PNP) M9PAV2 M9PA2 v v V v v Water resistant (2-color indicator) 2-wire 12 V M9BAV2 M9BA2 v v V v v 1 Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ
Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ DNote 1) When using the 2-color indicator type, please make the setting so that the indicator is lit in red to ensure the detection at the proper position of the air gripper.
Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Note 1) When using the 2-color indicator type, please make the setting so that the indicator is lit in red to ensure the detection at the proper position of the air gripper. 704 MHY2 Series 180 Angular Type Air Gripper Cam Type Specifications Air Fluid 0.1 to 0.6 MPa Operating
Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Refer to pages 837 and 838 for the details of solid state auto switch with pre-wired connector. Auto switches are shipped together, (but not assembled).
Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Refer to page 28 for applicable auto switches other than listed above. For details about auto switches with pre-wired connector, refer to pages 1192 and 1193. Auto switches are shipped together, (but not assembled).
14- 3. 5mm B B B A A () A B 0 A B A mm B Nm A B MHM-16D1 2 10 6 1.5 5 MHM-25D1 3 14 8 5.2 5 MHM-32D1 3 14 8 5.2 5 MHM-50D1 5 24 17 42 5 -15- D(mm) L(mm) MHM-16D1 14 25 MHM-25D1 19 37 MHM-32D1 19 43 MHM-50D1 30 63 4. 2 1 n /WEB Best Pneumatics m () 0.5 ( ) 3 (NPN) 3 (PNP) IC 2 3 (NPN) IC 3 (PNP) 2 PLC 2 3 (PNP) 3 (NPN) IC (2 ) 2 1 0.5mM9NW 1m M M9NWM 3m L M9NWL 5m Z M9NWZ
Lead wire length symbols 0.5 mNil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Solid state auto switches marked with a symbol are produced upon receipt of order. Since there are other applicable auto switches than listed, refer to page 599 for details. For details about auto switches with pre-wired connector, refer to pages 1014 and 1015.
. * Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM Water resistant (2-color indicator) 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ * Solid state auto switches marked with are produced upon receipt of order. * There are other applicable auto switches than listed above.
Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ There are other applicable auto switches other than the listed above. For details, refer to page 1197. For details about auto switches with pre-wired connector, refer to pages 1648 and 1649.
Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Solid state auto switches marked with are produced upon receipt of order. Mounting bracket (BMY3-016) is separately required to retrofit the above auto switches. There are other applicable auto switches other than listed above. For details, refer to page 1220.
Lead wire length symbols: 0.5 mNil (Example) M9NW 1 mM (Example) M9NWM 3 mL (Example) M9NWL 5 mZ (Example) M9NWZ Solid state auto switches marked with are produced upon receipt of order. Separate switch spacers (BMG2-012) are required to retrofit auto switches (M9 type) on cylinders 25 to 63. 2 1 m type lead wire is only applicable to D-A93.
Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M M9NWM 3 m L M9NWL 5 m Z M9NWZ 1
(Option) Amplifier Heater (Option) Ambient temperature: Max. 150C (Sensor) 2-color indicator An optional heater is available. Auto switches are mountable from 4 directions.
Symbol Nil None A B C Changed part XVD Without indicator With indicator Without indicator With indicator XLF100-30-1 XLF100A-30-1 XLF100-30-1H XLF100A-30-1H 5 to 60C 8-1 8-2 XGT 8-1 5 to 150C 8-2 Temperature specifications Symbol Nil 5 to 60C 5 to 150C H0 CYV Temperature Seal material: Same as the seal materials of How to Order Valve Same as How to Order Specifications Valve type Shaft seal
) Symbol -XB6 2 Heat Resistant Cylinder (10 to 150C) Bore size Stroke How to Order Standard model no.
Residence time of water at 20C is 5.5 x 10-6 sec, whereas at 150C it is 2.8 x 10-8 sec, or 200 times shorter. As an example, it took 800 minutes to evacuate moist air from a 150mm x 500mm P/A test chamber to 10-9Torr. The same process took only 4 minutes with dry (20ppb) nitrogen.
Residence time of water at 20C is 5.5 x 10-6 sec, whereas at 150C it is 2.8 x 10-8 sec, or 200 times shorter. As an example, it took 800 minutes to evacuate moist air from a 150mm x 500mm SMC test chamber to 10-9Torr. The same process took only 4 minutes with dry (20ppb) nitrogen.
(Except swivel elbow) Fluid temperature: 65 to 260C (Swivel elbow: 5 to 150C) Grease-free, Can be used with steam. Applicable tubing O.D.
(Option) Amplifier Heater (Option) Ambient temperature: Max. 150C (Sensor) 2-color indicator An optional heater is available. Auto switches are mountable from 4 directions.