Series: Standard, Mounting: MF1, Front Flange, Bore Size: 2 1/2", Stroke: 1/2", Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Nil (Small Male, Standard, Threaded), Adjustment Range: Not Applicable, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: Oversized Rod Cylinder
Series: Standard, Mounting: MF2, Rear Flange, Bore Size: 3 1/4", Stroke: 1/2", Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Nil (Small Male, Standard, Threaded), Adjustment Range: Not Applicable, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: Oversized Rod Cylinder
Series: Standard w/ Magnet, Mounting: MX0, Basic, Bore Size: 4", Stroke: 1/2", Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Nil (Small Male, Standard, Threaded), Adjustment Range: Not Applicable, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: Oversized Rod Cylinder
Series: Standard, Mounting: MS4, Side Tapped, Bore Size: 3 1/4", Stroke: 1/2", Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Nil (Small Male, Standard, Threaded), Adjustment Range: Not Applicable, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: Oversized Rod Cylinder
Series: Standard, Mounting: MX0, Basic, Bore Size: 4", Stroke: 1/2", Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Nil (Small Male, Standard, Threaded), Adjustment Range: Not Applicable, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: Oversized Rod Cylinder
Series: Standard, Mounting: MF2, Rear Flange, Bore Size: 4", Stroke: 1/2", Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Nil (Small Male, Standard, Threaded), Adjustment Range: Not Applicable, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: Oversized Rod Cylinder
Not applicable for types: Double rod (W), Trunnion (T), XC8, XC9, XC10, XC11, Over sized rod (XB5) with front mounts.
New Products Guide 1 Directional Control Valves Actuators Vacuum Equipment CAT.E00-6A INDEX New Products Guide 1 Directional Control Valves 5 Port Solenoid Valve Fieldbus System (For Input/Output) 2/3 Port Mechanical Valve Series SY3000/5000/7000 Series EX600 Series VM100/200 P .6 P .264 P .322 Actuators Foot Pedal Type 5 Port Mechanical Valve XT34-60/67 Air Cylinder Air Cylinder Series CJ2
MB1 Ex: NCDA1B 250-0200-XB5 CA2 Oversized/rod Auto switch capable CS1 C76 Oversized Rod-Basic Style: NCA1B (XB5) C85 P + Stroke LF + Stroke 2-EE (NPTF) C95 D across flats AA CP95 NCM NCA DSN + Stroke 4-DD Depth ND 4-NT -X ZB + Stroke 20MM KK A AA B BA C D DD E EA EE FA G J R ND NT TN WF XT Y LF P SN ZB Bore size (in) Data 200 (2") 2 7/8 5/16-24 1/2 0.3 3/8 3/8 1.26 1.06 1.84 7/16 5/16-18
MB1 Ex: NCDA1B 250-0200-XB5 CA2 Oversized/rod Auto switch capable CS1 C76 Oversized Rod-Basic Style: NCA1B (XB5) C85 P + Stroke LF + Stroke 2-EE (NPTF) C95 D across flats AA CP95 NCM NCA DSN + Stroke 4-DD Depth ND 4-NT -X ZB + Stroke 20MM KK A AA B BA C D DD E EA EE FA G J R ND NT TN WF XT Y LF P SN ZB Bore size (in) Data 200 (2") 2 7/8 5/16-24 1/2 0.3 3/8 3/8 1.26 1.06 1.84 7/16 5/16-18
Contents 150 NC1A150-PS 150 NC1A150-PS-XB5 200 NC1A200-PS-XB5 200 NC1A200-PS 250 NC1A250-PS 250 NC1A250-PS-XB5 325 NC1A325-PS 325 NC1A325-PS-XB5 400 NC1A400-PS 400 NC1A400-PS-XB5 Rod Option: Double Rod Option: Double, Special Option: Oversized Rod Bore Size (mm) Kit no. Contents Bore Size (mm) Kit no.
www.stevenengineering.com I 1.79 LINEAR ACTUATORS: AIR CYLINDERS SERIES NCA1 D I M E N S I O N S O V E R S I Z E D R O D F R O N T F L A N G E M O U N T I N G T Y P E NC A1F (XB5) BORE (INCH) KK A AA B BA C D DD E EA EE F G J R Y LF P ZB MM TF UF W FB WF 200 (2) 1 1/8 2.6 1.5 1 1/8 1/2 5/16-24 2 1/2 0.3 1.26 1.06 1.84 2.09 3 5/8 2.40 5 1/8 1 3 3/8 4 1/8 1 1 3/8 3/4-16 7/8 3/8 3/8 3/8 250
www.stevenengineering.com I 1.80 LINEAR ACTUATORS: AIR CYLINDERS SERIES NCA1 D I M E N S I O N S O V E R S I Z E D R O D D E TA C H A B L E R E A R C L E V I S M O U N T I N G T Y P E NC A1D (XB5) XD BORE (INCH) KK A AA B C D DD E EA EE FA G J M MM WF P ZD CD LR F L LF CB CW Y 6 1/8 200 (2) 1 1/8 2.6 1.5 1/2 5/16-24 2 1/2 0.3 1.26 1.06 1 1 3/8 2.40 6 5/8 3 5/8 2.09 3/4-16 7/8 3/8 3/8 1/2
. 1M Pa 0. 0050. 5M Pa SETTI N G PRESSU RE 0. 0050. 9M Pa PO W ER VO LTAG E D C24V 10% CO N SU M PTI O N CU RREN T AT CO N STAN T O U YPU T 120M a O R LESS I N PU T SI G N AL D I G I TAL 10bi t ( PARALLEL I N PU T) I N PU T I M PED AN CE 4. 7k O R LESS LI N EARI TY 1% F.
Speci f i cat i ons I TV1010 I TV1030 I TV1050 I TV2010 I TV2030 I TV2050 I TV2090 M odel I TV3010 I TV3030 I TV3050 M i ni m um suppl y pressure Set pressure + 0. 1M Pa Set pressure 13. 3kPa M axi m um suppl y pressure 0. 2M Pa 1. 0M Pa 1. 0M Pa 101kPa Set pressure range 0. 0050. 1M Pa 0. 0050. 5M Pa 0. 0050. 9M Pa 1. 380kPa Vol t age D CV Pow er source Current consum pt i on A or l ess
Speci f i cat i ons I TV1010 I TV1030 I TV1050 I TV2010 I TV2030 I TV2050 I TV2090 M odel I TV3010 I TV3030 I TV3050 M i ni m um suppl y pressure Set pressure + 0. 1M Pa Set pressure 13. 3kPa M axi m um suppl y pressure 0. 2M Pa 1. 0M Pa 1. 0M Pa 101kPa Set pressure range 0. 0050. 1M Pa 0. 0050. 5M Pa 0. 0050. 9M Pa 1. 380kPa Vol t age D CV Pow er source Current consum pt i on A or l ess
Dimension changes for Options Oversized rod (XB5 Option) Rotated Ports (XC3 Option) Port standard location Head end KK MM B Rod end Cushion location standard WF ZJ + Stroke A How to Order: -XC3 Port Cushion Standard Part Number Location.
Oversized rod -XB5 Special port positions -XC3 1 3 The strength of the cylinder is increased by increasing the diameter of the piston rod. This cylinder is used when the stroke is long, and there is a danger of the piston rod bending or buckling, etc. (Please contact SMC in case a lateral load will be applied.)
Oversized Rod Cylinder -XB5 Special Port Position -XC3 1 4 A cylinder that has been made stronger through the use of a piston rod with a larger diameter. It is used for long stroke applications that pose the risk of bending or buckling of the piston rod. (Consult with SMC if a lateral load must be applied to it.)
: Oversized Rod Cylinder Symbol -XB5 1 Oversized Rod Cylinder A cylinder that has been made stronger through the use of a piston rod with a larger diameter.