As a guide, it should be replaced after 6000 to 8000 hours of operation.
For the HRS012/018/024/030 option “T” (high-pressure pump) and the HRS050/060, after 8000 hours, alarm code “AL28” (pump maintenance) will be activated.
We recommend that you check for leaks and replace the mechanical seal at this time. Consider requesting maintenance from a maintenance company.
& N5-G3 5.3 AIR PREPARATION MODULAR TYPE AIR FILTER SERIES (N)AF D I M E N S I O N S NAF10002000 Port Size M5 1 Autodrain available New super efficient 5m Poly-element Quick release bowl guard on some sizes High flow T E C H N I C A L SPECIFICATIONS Model NAF1000 NAF2000 NAF3000 NAF4000 NAF5000 NAF6000 Port size M5x0.8 18 14 14 38 38 12 34 1 1 Flow rate ln/min* 140 1050 2800 5000 7000 8000
.---1798(8000) /' /' _ I 574 (7000) / z 080 ~1348 (6000) ./ 1124 (5000) !lOO (4(00) ./ --.63 --675 (3000) / I 050 -225 (IOOO) 4SO (2000) I 0 14.5 (01) 29 (0.2) 43.5 (O.3) 58 (0.0) 72.5 (0.5) PSI (MPa) Retaining lorce is the capability that can retain a Slatic load with no vlbrallOn or impact after locking.
2270 3390 4935 7685 12835 20625 150 3700 5355 8340 13800 22035 20 25 32 40 50 63 80 100 890 1130 1815 2765 4095 6380 10990 17795 785 985 1585 2455 3675 5730 9935 16385 670 840 1360 2140 3255 5075 8965 14970 650 815 1310 2080 3170 4945 8775 14685 625 785 1265 2015 3085 4815 8580 14405 605 755 1220 1955 3000 4685 8385 14120 580 725 1175 1895 2915 4550 8195 13840 560 700 1130 1830 2835 4420 8000
CKZT80 150 mm 150 mm 300 mm 400 mm Relation between clamp arm length and clamping force Relation between clamp arm length and maximum clamping force (operating pressure 0.5 MPa) Relation between clamp arm length and maximum clamping force (operating pressure 0.5 MPa) 10 2500 9000 For Asia For North America For Europe For France Special Maximum clamping force (lbf) Maximum clamping force (N) 8000
must be noted, however, that oversized piston rods transmit more side load 2400 19 45 75 114 145 213 281 347 than is the case with more flexible smaller rods; therefore, the use of oversized 3200 16 41 67 103 130 194 261 329 4000 13 38 63 94 119 175 240 310 rods should not be considered a remedy against excessive side loads. 5000 9 34 60 87 110 163 225 289 6000 5 30 56 82 102 152 208 274 8000
How to Order IZS31 CP X13 L (Tolerance 1%) Cable length 60 L: Cable length Symbol 7 01 02 04 05 06 07 08 09 11 12 13 14 15 16 17 18 19 20 1000 mm 2000 mm 4000 mm 5000 mm 6000 mm 7000 mm 8000 mm 9000 mm 11000 mm 12000 mm 13000 mm 14000 mm 15000 mm 16000 mm 17000 mm 18000 mm 19000 mm 20 mm (Red) 1 12 (6.2) 3 Cable Specifications No. of cable wire 12 0.14 mm2 (AWG26) 0.48 mm Nominal cross section
mm Blue, Brown 0.7 mm White, Green, Light green, Purple, Gray, Yellow Insulator Outside diameter 3000 Material Outside diameter Heat resistant PVC 6.2 mm Sheath 9800 Remote controller Infrared rays generating part 7 21 48 14 100 2 AAA batteries to be set 17 Transition wiring cable/IZS41-CF 17.5 17.5 16.4 6.2 B A 1 5 BA 5 1 L (mm) IZF41-CF02 IZF41-CF05 IZF41-CF08 16.4 Part no. 2000 5000 8000
Critical pressure 0.6 0.5 Sonic 0.5 0.4 0.4 0.3 0.3 0.2 0.2 0.1 0.1 JSXD30 Port size 1/4 JSXD30 Port sizes 3/8, 1/2 JSXD40 Port size 3/8 JSXD40 Port size 1/2 JSXD50 Port size 3/4 JSXD60 Port size 1 10 1000 2000 3000 10 1000 2000 3000 4000 15 2000 4000 6000 8000 15 2500 5000 7500 10 20 5000 10 15000 25 5000 10 15000 20 Flow rate Q [L/min (ANR)] For Air (Orifice diameter: 35 mm, 40 mm, 50 mm
Process data Conversion formula Inclination a 0x1F40 (8000) 0x1F41 (8001) 0x1F42 (8002) 0x1F43 (8003) 0 R N F32 Refer to Table "Inclination and intercept to the unit specification".
The recommend life time of the mechanical seal before needing replacement is 6000 to 8000 hours (usually 1 year) Check point to see leakage Fig. 8-3 Check for water leakage from pump HRS Series 8.2 Inspection and Cleaning 8-5 HRX-OM-M090 Chapter 8 Control, Inspection and Cleaning 8.2.5 Inspection for winter season Prevention of freezing of circulating fluid The product can prevent freezing
The recommend life time of the mechanical seal before needing replacement is 6000 to 8000 hours (usually 1 year) Check point to see leakage Fig. 8-3 Check for water leakage from pump HRS Series 8.2 Inspection and Cleaning 8-5 HRX-OM-R016 Chapter 8 Control, Inspection and Cleaning 8.2.5 Inspection for winter season Prevention of freezing of circulating fluid The product can prevent freezing
The recommend life time of the mechanical seal before needing replacement is 6000 to 8000 hours (usually 1 year) Check point to see leakage Fig. 8-3 Check for water leakage from pump HRS Series 8.2 Inspection and Cleaning 8-5 HRX-OM-W038 Chapter 8 Control, Inspection and Cleaning 8.2.5 Inspection for winter season Prevention of freezing of circulating fluid The product can prevent freezing
The recommend life time of the mechanical seal before needing replacement is 6000 to 8000 hours. Fig. 7-3 Check for water leakage from pump 7.2 Inspection and Cleaning HRS Series 7-6 HRX-OM-S004 Chapter 7 Control, Inspection and Cleaning 7.2.5 Inspection during winter season Keep the power supply ON for these functions. These functions do not start when the power is OFF.
0040 Reading internal sensor temperature 1 :01 03 0040 0001 BB [CR][LF] :01 03 02 09E1 10 [CR][LF] Answer 25.29 deg.C. 0041 Reading external Sensor temperature 1 :01 03 0041 0001 BA [CR][LF] :01 03 02 09E1 10 [CR][LF] Answer 25.29 deg.C. 0043 Reading status 1 :01 03 0043 0001 B8 [CR][LF] :01 03 02 0005 F5 [CR][LF] Run with alarm 0044 Alarm flag 1 1 :01 03 0044 0001 B7 [CR][LF] :01 03 02 8000
PA07 1 (Positioning mode) 20 12000 6000 24000 16000 8000 30 20 10 Function selection A-3 PA21 0001 2001 (J3 electronic gear setting value compatibility mode) Feel length multiplication (STM) (Multiplier) PT03 0 0 ((<1000 stroke)/0001 (>1000 stroke) Home position return type PT04 0010 3 (Stopper type) Home position return direction PT04 0010 1 (Motor side) Home position return Speed (rpm)
AF3000 AR2500 AF3000 AR3000 AF4000 AR4000 Combination equipment Air filter Regulator 1/8 1/4 1/4 3/8 1/4 3/8 3/4 1 1/4 3/8 1/2 Port size M5 X 0.8 3/4 1 1 1/16 1/8 1/8 1/8 1/4 1/4 1/4 1/4 1/4 Gauge port size Fluid Air 1.5 MPa 1.0 MPa Proof pressure Max. operating pressure 0.05 to 0.85 MPa 0.05 to 0.7 MPa Set pressure range 550(1/4) 1500(3/8) 2000(3/8) 4000(1/2) 5000(3/4) 6000(3/4) 7000(1) 8000
must be noted, however, that oversized piston rods transmit more side load 2400 19 45 75 114 145 213 281 347 than is the case with more flexible smaller rods; therefore, the use of oversized 3200 16 41 67 103 130 194 261 329 4000 13 38 63 94 119 175 240 310 rods should not be considered a remedy against excessive side loads. 5000 9 34 60 87 110 163 225 289 6000 5 30 56 82 102 152 208 274 8000
address for setting Item Setting value Default value AXIS AXIS AXIS AXIS 1 2 3 4 00: Positioning complete Da.1 Operation pattern 01: Continuous positioning control 11: Continuous path control a Da.2 Control system b (Note 1) b c Setting value 0:Pr.9 Acceleration time 0 1:Pr.25 Acceleration time 1 2:Pr.26 Acceleration time 2 3:Pr.27 Acceleration time 3 Da.3 Acceleration time No. 0H 2000 8000
This is accomplished using the same compact controller for either mode, and there is no "hand-shaking" with a separate PID controller.Sensor flow range: 1~8000, Operating pressure: 0~0.5 MPa, Flow controller communication protocol: RS232, Port size: 1/4" O.D., 3/8" O.D., ULTRASONIC FLOW SENSOR, ULTRASONIC FLOW SENSOR, 330 lb