SMC Corporation of America
Elite Part Number Search
Search Results "PF3A701H-LN-M-R"

entry Nil R U Without light/surge voltage suppressor With surge voltage suppresser With light/surge voltage suppresser For DC 24, 12, 6, 5, 3 VDC Grommet L plug connector M plug connector L: With lead wire (Length 300 mm) M: With lead wire (Length 300 mm) MN: Without lead wire G: Lead wire Length 300 mm H: Lead wire Length 600 mm ++ ++ LN: Without lead wire LO: Without connector MO: Without

Please contact SMC regarding water resistant types with the above model numbers. 2 1 m lead wire is only applicable to the D-A93. None N (Example) H7CN Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ Since there are other applicable auto switches than listed above, refer to page 111 for details.

P R R P R A A A A A 14 19.5 11 10 30.7 31.5 29 52.9 [55.1] 53.7 [55.9] B B B B B M5 x 0.8 (P, R port) 2-3.5 (For mounting) M3 x 0.5 (A, B port) L2 3.5 L1 (Station 1) (Station n) (Light/surge voltage suppressor) + + + + + 42 [49] 26.6 13.5 L plug connector (L) M plug connector (M) M8 connector (W0) (Lead wire length) Approx. 300 42 [49] 26.6 M8 x 1 53.1 [60.1] Approx. 300 (Lead wire length

(Value in the initial state) Base mounted Solenoid Specifications JIS Symbol 5 port 4 port (manifold) Grommet (G), (H), L plug connector (L), M plug connector (M), M8 connector (W) 2 position single 2 position single Electrical entry (B) 2 (A) 4 (B) 2 (A) 4 24, 12, 6, 5, 3 DC Coil rated voltage (V) 100, 110, 200, 220 AC 50/60 Hz 1 (P) 1 (P) 3 (R) 3 (R) 5 (R) Allowable voltage fluctuation

P R R P R A A A A A 87.2 [91.6] 33 47 44.2 [46.4] 22.1 (DIN 23.3) 43.6 [45.8] B B B B B 2.5 1/8 (P, R port) (Pitch) P = 16 Manual override 21 (Station n) (Station 1) Built-in speed controller (Light/surge voltage suppressor) 48.6 [55.6] + + + + + 33.2 12 20 M5 x 0.8 (A, B port) 24 Max. 13.5 43.5 (Pitch) P = 16 23 L plug connector (L) M plug connector (M) M8 connector (W0) DIN terminal (D)

P R A B A B A B A B A B 30 R P R 21 21 83.7 [85.9] 84.5 [86.7] 17 21 60 1/4 (P, R port) Manual override 1/8 (A, B port) (Pitch) P = 19 23.5 Built-in one-touch fitting (Station n) (Station 1) (Light/surge voltage suppressor) One-touch fitting (A, B port) Applicable tubing O.D.: 6, 1/4" 8, 5/16" 58.5 [65.5] + + + + + 43.1 26.5 (4.9) 63 L plug connector (L) M plug connector (M) DIN terminal

Approx. 300 (Lead wire length) 35 (DIN 36.2) 21.5 17 A A A A X X 57.1 [59.3] 20.5 38 2-5.5 (For mounting) 1/8 (P, R port) M5 x 0.8 (A port) (Pitch) P=16 23 Manual override L1 L2 4.5 (Station 1) (Station n) (Light/surge voltage suppressor) + + + + 54.1 [61.1] 38.7 25.5 DIN terminal (D) M8 connector (W0) L plug connector (L) M plug connector (M) 49 49 49 49 P R P R P R P R 57.2 [59.4] 52.2

(L): SYJ34-L-M5 M plug connector (M): SYJ34-M-M5 M8 connector (W0): SYJ34-W0-M5 Approx. 300 (Lead wire length) 41.5 [48.5] 26.1 46 M8 x 1 28.5 52.6 [59.6] Approx. 300 (Lead wire length) 58.5 [60.7] 48.7 [50.9] 57.6 50.2 43.7 R P R P R P 10 8.6 10 8.6 10 8.6 23 23 23 5 5 5 28.5 28.5 28.5 35.6 35.6 35.6 Refer to the page 68 for dimensions with connector cable. 6 Series SYJ300 Manifold Specifications

+ 128.2 W = 13n + m + 36 W = 41.2n + m + 77.6 (n: Number of SUP/EXH blocks, m: DIN rail weight) Note 1) In cases such as when many valves are operated simultaneously, supply pressure to port P on both sides and exhaust from port R on both sides, using "stations B (SUP/EXH block both sides)".

3zo r t I r-V-ru ?sdm,{t-!:-!!.Fst-r ?i,oxl+4r5"a, I l r c o M " I r + r t r c o M c , + l ll coM" i q (+) ( coMo ro(+) /r'Y;-"' M* fr'fi-"" ' ire!.f s | ) ,-Js!jr L , 3 smms { l'.;+_2. ( ) ( L--!9!!" zz r +r 3sd5{fj:3'?L i 3 idb61f-1:-_r: ( ' tl co 22 l+) tL-Lg!!"r5 L+' tL-l-s!" 5 (+ (Note 1)Maximum slalion I (Nole2)(+)aid()indicabnredireclionolDCsolnoidvalvewthliqhi.su'ge!

(M5)) (ln ca8e of % NPTF) M Vpe plug connector(M) L typ plug connector(L) 133S (340) ',3.A3 (3&) lo-32Nom. (Ms) Tgpe 40 Manifold,/ Bottom Ported(External Pilot) inch (mm) Grommet (c), (H) (ln case ol lo-3zNorn, (M5)) L type plug connector(L) 13.78 (s50) 13.,13 (s41) r3.19 (35) Symbol (internal pilot tpe) N.C. N.O. slJrb s-zrJh P R P R w (external pilot type) N.C. N.O.

IDX-OM-W029-B / Series IDU22E-23(-C,L,R,T,V) IDU22E-30(-C,L,M,R,T) IDU37E-23(-C,L,R,T,V) IDU37E-30(-C,L,M,R,T) IDU55E-23(-C,L,R,T,V) IDU55E-30(-C,L,M,R,T) IDU75E-23(-C,L,R,T,V) IDU75E-30(-C,L,M,R,T) URLhttps://www.smcworld.com/ English instruction manual can be downloaded from our URLhttps://www.smcworld.com/ SMC () * 1 ) JIS B8370 * 2 ) ISO4414 *1) ISO4414Pneumatic fluid power General

My = 1 x 9.8 (10 + 30)/1000 = 0.39 A3 = 30 Find the static moment M (Nm). M = W x 9.8 (Ln + An)/1000 Corrected value of moment center position distance An: Table 3 Find the allowable static moment Ma (Nm).

Silencer Tubing bore x Length Speed controller Silencer Tubing bore x Length Speed controller Silencer Tubing bore x Length Speed controller Silencer AS2051F-06 AN120-M5 AS3001F-06 AN110-01 SY3120-C6 SY3140-01 T0604 x 1 m T0806 x 1 m AS3001F-06 T0604 x 1 m T0806 x 1 m AS3001F-08 AS3001F-06 SY5120-01 SY5140-02 AS3001F-08 AN101-01 AN101-01 T1075 x 1 m T0604 x 1 m T0604 x 1 m T1209 x 1 m T1075

Mr = 0.5 x 9.8 (30 + 17)/1000 = 0.23 A6 = 17 Mar = 9.14 (Same as May) M = W (Ln + An)/1000 Moment center position distance compensation amount An: Table (3) Ma = KMmax Workpiece mounting coefficient K: Fig. (3) Allowable moment coefficient : Graph (2) Maximum allowable moment Mmax: Table (4) Find the static moment M (Nm).

Response t me 1.Zns ' Shock resistance 300 m/s'(reed swrtch) 1000 m/s'(solid state s',vitch) Flange & Auto Switch Mounting Brqcket Weights NCDRBIOWI0.15.20.30 Rotation Time Setting Fitting Loeation And. Rotation Of Auto Switch luto Swilch 9(r, 160' Ewn a small torque generated by the rotary actuator. due to inertia, can cause qamage.

www.stevenengineering.com I 2.65 SOLENOID VALVES SERIES (N)VZ500 H O W T O O R D E R M A N I F O L D T Y P E 41 B O T T O M P O R T E D D I M E N S I O N S M A N I F O L D T Y P E 41 B O T T O M P O R T E D G R O M M E T T Y P E (N)VV3Z5 41 01T 2 N U M B E R O F S TAT I O N S T H R E A D T Y P E 02 2 Stations to 20 20 Stations PT T NPTF F O R A L L O T H E R D E TA I L S, R E F E R T O T

Cable length VVFS2000-30A-1 VVFS2000-30A-2 VVFS2000-30A-3 VVFS2000-30A-4 VVFS2000-30A-5 VVFS2000-30A-6 VVFS2000-30A-7 1.5 m 3 m 5 m 7 m 10 m 15 m 20 m 1.5 m 3 m 5 m 8 m 10 m 15 m 30 m VVZS3000-21A-1 VVZS3000-21A-2 VVZS3000-21A-3 VVZS3000-21A-4 VVZS3000-21A-5 VVZS3000-21A-6 VVZS3000-21A-7 Plug 206837-1 1 pc. Cable clamp 206138-1 1 pc. Socket 66101-2 24 pcs.

EXH port] (C12 in case of branch type) C10 [3(R) EXH port] C10: 10 One-touch fitting made by CONINVERS GmbH Circular connectors (26 pins) C10: 10 One-touch fitting (C12: 12 One-touch fitting) DIN rail clamp screw R R 76.5 3 3 X X AXT100-MC26-050: 5 m AXT100-MC26-030: 3 m AXT100-MC26-015: 1.5 m Circular connector cable assembly 60 (12) (7.5) 49.5 B B B B B B B B 12 P12 P 30 25 18 1 1 A A