SMC Corporation of America
Elite Part Number Search
Search Results "PF3W520-N03-1TN-R"

PF2W520 PF3W520 PF2W540 PF3W540 PF2W511 PF3W511 PF2W504 PF3W504 Function selection mode Safety Instructions Other functions Sensor connector Mounting and Installation PF2D2 series Lever Warning Installation or Channel scan function Peak / Bottom value display Key-lock function PF2D520 PF2D540 PF2D504 Do not disassemble, modify (including changing the printed circuit board) or repair.

50 g 100 g 1OFF (2 5 ) 5 100 (24 5 min100 500 min9.5 ) 290(7 s) 390(7 s) -67No.PF-OMN0011CN-C 0100 1 / -10110 1 3F.S. 7 s 2 5F.S. 1090 2 (ZS-40-W) AWG26 0.51 mm 1.00 mm 3.5 mm -68No.PF-OMN0011CN-C / (PF3W704/720740) A B C 1 V 1.5 V 5 V 4 mA 6 mA 20 mA (PF3W711) A B C 1 V 1.4 V 5 V 4 mA 5.6 mA 20 mA (PF3W721) A B C 1 V 1.5 V 5 V 4 mA 5.9 mA 20 mA [L/min] PF3W504 0.5 4 PF3W520

Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 04 (1/2), Output Specification/Temperature Sensor: 1T (Out 1 Flow Rate: Analog 1 to 5 V; Out 2 Temperature: Analog 1 to 5 V; Temperature Sensor: w/Temperature Sensor), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: Instantaneous Flow: L/min, Temperature:

Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: F (G), Port Size: 03 (3/8), Output Specification/Temperature Sensor: 1T (Out 1 Flow Rate: Analog 1 to 5 V; Out 2 Temperature: Analog 1 to 5 V; Temperature Sensor: w/Temperature Sensor), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: Instantaneous Flow: L/min, Temperature: °

Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 04 (1/2), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor), Lead Wire: N (w/o Lead Wire w/M8 Connector), Units on Label: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C)

Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 03 (3/8), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor), Lead Wire: N (w/o Lead Wire w/M8 Connector), Units on Label: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C), Bracket: R (Bracket)

Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: NPT, Port Size: 1/2, Output Specification/Temperature Sensor: Out 1 Flow Rate: Analog 1 to 5 V; Out 2 Temperature: Analog 1 to 5 V; Temperature Sensor: w/Temperature Sensor, Lead Wire: w/o Lead Wire and M8 Connector, Unit Specification: Instantaneous Flow: L/min, Temperature: °C, Bracket: None, Calibration

Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: G, Port Size: 3/8, Output Specification/Temperature Sensor: Out 1 Flow Rate: Analog 1 to 5 V; Out 2 Temperature: Analog 1 to 5 V; Temperature Sensor: w/Temperature Sensor, Lead Wire: w/o Lead Wire and M8 Connector, Unit Specification: Instantaneous Flow: L/min, Temperature: °C, Bracket: None, Calibration

Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1/2, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: w/o Lead Wire w/M8 Connector, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: -, Calibration Certificate: -, Made to Order: -

Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: None, Thread: Rc, Port Size: 3/8, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: w/o Lead Wire w/M8 Connector, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: Bracket, Calibration Certificate: -, Made to Order: -

(R) Vacuum spec. (V) Standard External pilot spec. (R) Standard External pilot spec. (R) Vacuum spec. (V) Standard External pilot spec. (R) Vacuum spec. (V) Port size Vacuum spec.

D E R S E R I E S (N)AS1000-4000 S Y M B O L S NAS 3 000 A R E A C O D E Japan, Asia, Australia, UK N Canada, USA P O R T T H R E A D P A N E L M O U N T V E R S I O N R(PT) N NPT B O D Y S I Z E P O R T S I Z E 1 M3, M5 2 1/8, 1/4 Standard 3 3/8 Standard 4 1/2 Standard M3 M3x0.5 M5 M5x0.8 01 1/8 (10-32Nom) 02 1/4 03 3/8 04 1/2 T E C H N I C A L SPECIFICATIONS D I M E N S I O N S S E R I

Note 2) Monilor output is switch output lype only. series ITV 1 000/2000/3000 Made to Order Specifications Contact SMC regarding detailed dimensions, specilications and delivery times. 2 through I slation manifold. llTv2o -tHow to Order Manifolds How to Order Manifold Assemblies Tlsl -r a Valve stations f , T, st"tb"t tl-r-'r I | 8 stations Example I ,turooo, r*o I port size 02 1/4 G' 3la

AC 110 12 2 12 3 q e w e t y 220 10 1 10 1.5 440 6 1 3 1 550 5 0.8 2 0.5 r b contact w a contact r q DC 24 3 2.5 3 2.5 C C 48 1.5 1.2 1.5 1.25 When rising pressure q w = ON e r = OFF When rising pressure q e r y = ON q w r t = OFF 110 0.5 0.25 0.5 0.2 220 0.25 0.1 0.25 0.1 Insulation resistance: 100 M or more at 500 VDC by megameter Voltage resistance: 2000 VAC/1 min. 16-9-5 2 Series

The pressure in the pilot chamber e increases and operates on the upper surface of the diaphragm r. As a result, the air supply valve t linked to the diaphragm r opens, and a portion of the supply pressure becomes output pressure. This output pressure feeds back to the control circuit i via the pressure sensor u.

I E S A U I T O D R A I N S S Y M B O L S H O W T O O R D E R A U T O D R A I N S E R I E S AD AD402-02 (1/4) PT AD402-03 (3/8) PT AD402-04 (1/2) PT AD600-06 (3/4) PT AD600-10 (1) PT H O W T O O R D E R A U T O D R A I N S E R I E S NAD NAD402-N02 (1/4) NPT NAD402-N03 (3/8) NPT NAD402-N04 (1/2) NPT NAD600-N06 (3/4) NPT NAD600-N10 (1) NPT FOR FURTHER TECHNICAL DETAILS ON THIS PRODUCT CONSULT

Connection NPT 1/8 IR2000 series N01 Connection NPT 1/4 N02 Connection NPT 3/8 N03 Connection NPT 1/2 N04 Connection G 1/8 F01 Connection G 1/4 F02 Connection G 3/8 F03 Connection G 1/2 F04 IR1000 series Photos are when a pressure gauge is mounted.

VH*-OMX0068-A PRODUCT NAME Pressure Relief 3 Port Valve with Locking Holes MODEL / Series / Product Number VHS20-(F,N)01~(F,N)02(-R,Z)-D VHS30-(F,N)02~(F,N)03(-R,Z)-D VHS40-(F,N)02~(F,N)04(-R,Z)-D Contents Page 1. Safety Instructions 1~5 2. Application 6 3. Specifications 6 4. How to Order 7~8 5. Construction / Parts List 9 6.

(A) 2 4.5(0.25) 9.0(0.5) Refer to Best Pneumatics Vol. 4 for further details. 3 (R) 1 (P) 3 (R) 1 (P) Specifications Mist separator Series AM Model Compressed air 1.0 MPa 0.05 MPa 1.5 MPa 5 to 60C 0.3 m (95% filtered particle diameter) Fluid Max.operating pressure Model AM150 AM250 Rated flow l/min (ANR) 300 750 Min. operating pressure (1) Proof pressure Port