Rated Flow Range: 50 to 250 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1 1/2, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: -, Units on Label: -, Bracket: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 50 to 250 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1 1/2, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: w/o Lead Wire w/M8 Connector, Units on Label: -, Bracket: -, Calibration Certificate: -, Made to Order: -
min100 500 min9.5 ) 290(7 s) 390(7 s) -67No.PF-OMN0011CN-C 0100 1 / -10110 1 3F.S. 7 s 2 5F.S. 1090 2 (ZS-40-W) AWG26 0.51 mm 1.00 mm 3.5 mm -68No.PF-OMN0011CN-C / (PF3W704/720740) A B C 1 V 1.5 V 5 V 4 mA 6 mA 20 mA (PF3W711) A B C 1 V 1.4 V 5 V 4 mA 5.6 mA 20 mA (PF3W721) A B C 1 V 1.5 V 5 V 4 mA 5.9 mA 20 mA [L/min] PF3W504 0.5 4 PF3W520 2 16 PF3W540 5 40 PF3W511 10 100 PF3W521
Rated Flow Range: 21 (50 to 250 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 12 (1 1/4), Output Specification: 2 (OUT1: Analog 4 to 20mA), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C), Bracket: None, Calibration Certificate: A (Calibration Certificate)
Rated Flow Range: 21 (50 to 250 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 12 (1 1/4), Output Specification: 2 (OUT1: Analog 4 to 20mA), Temperature Sensor: None, Lead Wire: N (w/o Lead Wire w/M8 Connector), Units on Label: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C), Bracket: None, Calibration Certificate: A (Calibration Certificate)
Rated Flow Range: 21 (50 to 250 L/min), Port, PVC Pipe O.D.: 30 (Port Size: 30A, Pipe O.D.: 38mm), Output Specification: 2 (OUT1: Analog 4 to 20mA), Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C), Bracket: None, Calibration Certificate: A (Calibration Certificate)
Rated Flow Range: 50 to 250 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1 1/4, Output Specification: OUT1: Analog 4 to 20mA, Temperature Sensor: None, Lead Wire: w/o Lead Wire w/M8 Connector, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: None, Calibration Certificate: Calibration Certificate, Made to Order: -
Rated Flow Range: 50 to 250 L/min, Port, PVC Pipe O.D.: Port Size: 30A, Pipe O.D.: 38mm, Output Specification: OUT1: Analog 4 to 20mA, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: None, Calibration Certificate: Calibration Certificate
Series PF3W digital flow switch is perfect for applications requiring a constantly monitored flow of cooling or cleaning water. The PF3W series has been improved both in design and operating performance over the PF2W flow switch. Depending on the selected model, the PF3W is up to 40% smaller in volume, offering improved piping space and flexibility. Designed to work with fluids up to 90ºC
: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 10 (1), Output Specification: 2 (OUT1: Analog 4 to 20mA), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: None, Made to Order: X128
11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 06 (3/4), Output Specification: 2 (OUT1: Analog 4 to 20mA), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: None, Made to Order: X128
: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 04 (1/2), Output Specification: 2 (OUT1: Analog 4 to 20mA), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: None, Made to Order: X128
: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 04 (1/2), Output Specification: 2 (OUT1: Analog 4 to 20mA), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: None, Made to Order: X128
: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 06 (3/4), Output Specification: 2 (OUT1: Analog 4 to 20mA), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: None, Made to Order: X128
Flow Adjustment Valve: S (Flow Adjustment Valve), Thread: N (NPT), Port Size: 06 (3/4), Output Specification: 2 (OUT1: Analog 4 to 20mA), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: None, Made to Order: X128
Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 06 (3/4), Output Specification: 2 (OUT1: Analog 4 to 20mA), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: None, Made to Order: X128
Flow Adjustment Valve: S (Flow Adjustment Valve), Thread: N (NPT), Port Size: 04 (1/2), Output Specification: 2 (OUT1: Analog 4 to 20mA), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: None, Made to Order: X128
Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 04 (1/2), Output Specification: 2 (OUT1: Analog 4 to 20mA), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: None, Made to Order: X128
), Flow Adjustment Valve: S (Flow Adjustment Valve), Thread: F (G), Port Size: 03 (3/8), Output Specification: 2 (OUT1: Analog 4 to 20mA), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: None, Made to Order: X128
), Flow Adjustment Valve: S (Flow Adjustment Valve), Thread: F (G), Port Size: 03 (3/8), Output Specification: 2 (OUT1: Analog 4 to 20mA), Temperature Sensor: T (OUT2: Analog 1 to 5V, w/Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: None, Calibration Certificate: None, Made to Order: X128