Rated Flow Range: 21 (50 to 250 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 12 (1 1/4), Output Specification: 2 (OUT1: Analog 4 to 20mA), Temperature Sensor: None, Lead Wire: N (w/o Lead Wire w/M8 Connector), Units on Label: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C), Bracket: None, Calibration Certificate: A (Calibration Certificate)
Rated Flow Range: 21 (50 to 250 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 14 (1 1/2), Output Specification: 2 (OUT1: Analog 4 to 20mA), Temperature Sensor: None, Lead Wire: N (w/o Lead Wire w/M8 Connector), Units on Label: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C), Bracket: None, Calibration Certificate: A (Calibration Certificate)
Rated Flow Range: 50 to 250 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1 1/4, Output Specification: OUT1: Analog 4 to 20mA, Temperature Sensor: None, Lead Wire: w/o Lead Wire w/M8 Connector, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: None, Calibration Certificate: Calibration Certificate, Made to Order: -
Rated Flow Range: 50 to 250 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1 1/2, Output Specification: OUT1: Analog 4 to 20mA, Temperature Sensor: None, Lead Wire: w/o Lead Wire w/M8 Connector, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: None, Calibration Certificate: Calibration Certificate, Made to Order: -
Use nothing for Rc(PT), N for NPT and F for G(PF). G(PF) pressure gauge is unavailable.
Normally Closed VXZ 2230 02 1 G N.C. Normally Open VXZ 2232 02 1 G N.O.
Add 10 g for conduit type, 30 g for DIN terminal type, 60 g for conduit terminal type respectively.
0.6 lbs (275 g) Weight 0.75 lbs (340 g) Note 1) M12 (4-pin) connector can be connected.
The electrical entry port {VQ1000: G 1/2, VQ2000: G 3/4} permits connection of conduit fittings.
VVEX2-2-5-02 VY1200-00-G 4 pcs. VEX1-17 1 pc. Nil Rc G F N NPTF NPT In the case of VVEXB, the 2 in the first digit of the valve station number is a dummy part number.
Mounting screw (M4) Terminal block cover M3 screw Gasket 6 mm Electrical entry 2 x G 3/4 Step 3. Mounting the terminal block cover Securely tighten the screws to the torque shown in the table below, after confirming that the gasket is installed correctly.
Piping specifications Additional weight of 1 station g 5 station weight g Note 1) Port size Series Applicable solenoid valve Type of connection Applicable Base type stations P, R A, B Piping Port size C3 (for 3.2) C8 (for 8) C4 (for 4) Side SQ1000 C6 (for 6) J kit: Flat cable 1 to 8 stations SQ130 SQ131 420 20 Option SS5Q13Note 2) L3 (for 3.2) Built-in silencer Direct exhaust L4 (for 4) Top
x 1/4 ARM3000: 2n x 3/8 SRH SRP SRF ITV IC Dimensions For products with pressure gauge, pressure gauges are shipped together with product.
Rated Flow Range: 50 to 250 L/min, Port Size, Pipe O.D.: Port Size: 30A, Pipe O.D.: 38mm, Output Specification: OUT1: NPN; OUT2: Analog 1 to 5V, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 50 to 250 L/min, Port Size, Pipe O.D.: Port Size: 30A, Pipe O.D.: 38mm, Output Specification: OUT1: NPN; OUT2: NPN, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 50 to 250 L/min, Port Size, Pipe O.D.: Port Size: 30A, Pipe O.D.: 38mm, Output Specification: OUT1: NPN; OUT2: Analog 4 to 20mA, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 50 to 250 L/min, Port Size, Pipe O.D.: Port Size: 30A, Pipe O.D.: 38mm, Output Specification: OUT1: PNP; OUT2: PNP, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 50 to 250 L/min, Port Size, Pipe O.D.: Port Size: 30A, Pipe O.D.: 38mm, Output Specification: OUT1: PNP; OUT2: Analog 4 to 20mA, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: -, Calibration Certificate: -, Made to Order: -
.: 38mm), Output Specification: C (OUT1: NPN; OUT2: Analog 1 to 5V), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C)