If the voltage increase ratio (dV/dt) at the zero cross should exceed 40 V/200 sec., it may result in malfunction. 2 min HRSE 1 min Max.
If the voltage increase ratio (dV/dt) at the zero cross should exceed 40 V/200 sec., it may result in malfunction. It is particularly impossible to use liquid including metallic powder such as iron powder. Voltage dV dt = Voltage increase ratio dV Time dt 211 HRSE Series Specific Product Precautions 4 Be sure to read this before handling the products.
If the voltage increase ratio (dV/dt) at the zero cross should exceed 40 V/200 msec., it may result in malfunction.
If the voltage increase ratio (dV/dt) at the zero cross should exceed 40 V/200 sec., it may result in a malfunction. Time HRW dt
In particular, if the voltage rate of increase (dv/dt) at zero crossing exceeds 40V/200sec, it may cause malfunction.
In particular, if the voltage rate of increase (dv/dt) at zero crossing exceeds 40V/200sec, it may cause malfunction.
In particular, if the voltage rate of increase (dv/dt) at zero crossing exceeds 40V/200sec, it may cause malfunction. V Voltage dV dt = Voltage ratio Voltage rise % on zero-cross point dV t Time dt *: For the product operation in the UL compliant conditions, please refer to "Installation/Operation in accordance with the UL standard" in the next page.
In particular, if the voltage rate of increase (dv/dt) at zero crossing exceeds 40V/200sec, it may cause malfunction.
In particular, if the voltage rate of increase (dv/dt) at zero crossing exceeds 40V/200sec, it may cause malfunction.
In particular, if the voltage rate of increase (dv/dt) at zero crossing exceeds 40V/200sec, it may cause malfunction.
In particular, if the voltage rate of increase (dv/dt) at zero crossing exceeds 40V/200sec, it may cause malfunction. V Voltage dV dt = Voltage ratio Voltage rise % on zero-cross point dV t Time dt * For the product operation in the UL compliant conditions, refer to Installation/Operation in accordance with the UL standard in the next page.
Operating time 20 s 30 s Voltage 10 s 5 s Min. 2 s dV dt 1 s = Voltage increase ratio 0.5 s dV 0.2 s 0.1 s Time 0.05 s 0.02 s dt 0.01 s 100 125 200 300 500 400 600 700 1000 2000 3000 4000 1500 < For option B [With earth leakage breaker]> 3. This product is installed with a breaker with the following operating characteristics.
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 10 (1), Output Specification: D (OUT1: NPN; OUT2: Analog 4 to 20mA), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: F (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °F), Bracket: R (Bracket)
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 10 (1), Output Specification: D (OUT1: NPN; OUT2: Analog 4 to 20mA), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C)
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 10 (1), Output Specification: D (OUT1: NPN; OUT2: Analog 4 to 20mA), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C)
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 10 (1), Output Specification: D (OUT1: NPN; OUT2: Analog 4 to 20mA), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: G (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C), Bracket: None, Calibration Certificate: A (Calibration
Rated Flow Range: 11 (10 to 100 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 10 (1), Output Specification: D (OUT1: NPN; OUT2: Analog 4 to 20mA), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: F (Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °F)
Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1, Output Specification: OUT1: NPN; OUT2: Analog 4 to 20mA, Temperature Sensor: Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °F, Bracket: Bracket, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1, Output Specification: OUT1: NPN; OUT2: Analog 4 to 20mA, Temperature Sensor: Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: None, Thread: Rc, Port Size: 1, Output Specification: OUT1: NPN; OUT2: Analog 4 to 20mA, Temperature Sensor: Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: -, Calibration Certificate: -, Made to Order: -