Allow at least 0.5 seconds from a locked stop (intermediate stop of the cylinder) until release of the lock. When the locked stop time is too short, the piston rod (and load) may lurch at a speed greater than the control speed of the speed controller.
It can be used at 50 to 1000 mm/s provided that it is within the allowable kinetic energy range.
Maximum piston speed: 1000 mm/s It can be used at 50 to 1000 mm/s provided that it is within the allowable kinetic energy range.
Allow at least 0.5 seconds from a locked stop (intermediate stop of the cylinder) until release of the lock. When the locked stop time is too short, the piston rod (and load) may lurch at a speed greater than the control speed of the speed controller. RLQ MLU ML1C 5.
maximum set pressure) Bleed hole: 3.5 l/min (ANR) or less (Supply pressure: 1.0 MPa) Exhaust port: 0.9 l/min (ANR) or less (at maximum set pressure) Bleed hole: 9.5 l/min (ANR) or less (Supply pressure: 1.0 MPa) Exhaust port: 2 l/min (ANR) or less (at maximum set pressure) Bleed hole: 3.5 l/min (ANR) or less (Supply pressure: 1.0 MPa) Exhaust port: 0.9 l/min (ANR) or less (at maximum set
Bore size (mm) 40 50 63 80 100 Foot * 90-CA1-L04 90-CA1-L05 90-CA1-L06 90-CA1-L08 90-CA1-L10 Flange 90-CA1-F04 90-CA1-F05 90-CA1-F06 90-CA1-F08 90-CA1-F10 Single clevis * When ordering foot bracket, order 2 pieces per cylinder.
Bank Point Home position sensor position 0. 1. 0 0 0 0 0 0 Moves to the motor side at home position return speed Decelerates and stops at the home position sensor ON position Moves to the end side at low speed Moves and stops at 16 pulse position from the home position sensor OFF position Coordinate attribute Coordinates Speed pattern Operating procedures 1.
Symbol Signal description Signal description Driver model MR-C10A MR-C20A MR-C10A1 MR-C20A1 Symbol Digital output power supply Failure Positioning complete Z phase pulse 1 2 3 4 5 7 8 9 10 11 12 13 14 15 16 17 19 20 V+ ALM PF OP SG NP NG PP PG Shield SD SG CR LSN LSP V5 SON OPC V24 Interface power supply common Clear Reverse stroke end Normal stroke end Interface power supply Servo ON Open
Note 2) To insert the T-nuts, remove the covers at both ends of the body and insert them into the T-slots.
the MR Configurator2TM instruction manual (Manual/ib0300160*.pdf) contained on the setup software (MR Configurator2TM) CD-ROM.
At this time, Monitoring (RXn8) turns to ON at the same time.
At this time, Monitoring (RXn8) turns to ON at the same time.
At this position, 2 mm at the end (size 25, 32) and 4 mm at the end (size 63). Note) When the motor mounting is the right or left side parallel type, the head side foot should be mounted outwards.
MR Configurator2TM instruction manual (Manual/ib0300160*.pdf) contained on the setup software (MR Configurator2TM) CD-ROM.
Designed to work with fluids up to 90ºC, these switches incorporate a built-in temperature sensor so both flow and fluid temperature can be effectively monitored at the same time.
to the MR Configurator2TM instruction manual (Manual/ib0300160*.pdf) contained on the setup software (MR Configurator2TM) CD-ROM.
", 1/4", 5/16", 3/8" 1/4" Inch size 5/32" 3/16" 5/16" 3/8" 1/2" 5/32" 5/16" 3/8" 3/16", 1/4" Controlled flow Free flow Flow rate (L/min (ANR)) 180 230 100 260 390 660 790 1580 1710 460 920 Sonic Conductance dm3/(sbar) 0.54 0.7 0.3 0.8 1.2 1.4 2 2.4 2.8 4.8 5.2 Critical pressure ratio Controlled flow 0.2 0.25 0.3 0.25 0.25 Free flow 0.4 0.2 0.3 0.2 0.3 Note) Flow rate values are measured at
Symbol Metric size 3.2, 4, 6 3.2, 4 6, 8, 10 8, 10 4 6 6 8 10 12 10, 12 Tubing O.D. 1/8", 5/32" 1/8" 3/16", 1/4" 1/4", 5/16" 3/8" 1/4" Inch size 5/32" 3/16" 5/16" 3/8" 1/2" 5/32" 5/16" 3/8" 3/16", 1/4" Controlled flow (Free flow) Flow rate (l/min (ANR)) 100 180 230 260 390 660 790 1580 1710 460 920 Effective area (mm 2) 1.5 2.7 3.5 4 6 7 10 12 14 24 26 Note) Flow rate values are measured at
AS421F AS431F Model 3.2, 4, 6 8, 10 Metric size 6, 8, 10 3.2, 4 4 6 6 8 10, 12 10 12 Tubing O.D. 1/8", 5/32" 3/16", 1/4" 3/16", 1/4" 5/16" 1/4", 5/16" 3/8" 1/8" 5/32" 1/4" Inch size 5/32" 3/16" 5/16" 3/8" 3/8" 1/2" Flow rate (l/min (ANR)) 100 230 180 260 390 460 660 790 920 1580 1710 Controlled flow (Free flow) 1.5 3.5 2.7 4 6 7 10 12 14 24 26 Effective area (mm2) Note) Flow rate values are at
Cantilever When the actuator is operated at high speed while it is fixed at one end and free at the other end (flange type, foot type, double clevis type, direct mount type), a bending moment may act on the actuator due to vibration generated at the stroke end, which can damage the actuator.