Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: 2T (Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector)
8 345 tl 2t /2-12 UN l 9 50 57 l 9 t 26 26 t0 25 Otl7rx6 456 4t3 77 2t /2-12 l 9 60 60 241 26 26 t0 25 All dimens ons rn millirneters. Notes: 1. A shock absorbers wil function sat sfactorily at 5% of the r maximum rated energy per cycre. lf ess tlran 5%, a sma ler model should be speciTied. 2. Airlo (AoEM.
Valve; w/Stop Valve), Supply/Return Port Size: 06 (3/4), Return Unit Flow Switch Output Specifications: 2T (Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: G (Remote Sensor: L/min/gal/min; °C; Integrated Display: gal/min; Accumulated Flow: gal;
Stations: 5 Stations, Piping: U Side: Open; D Side: Open, Thread Type: NPT, Supply Unit Components: w/o Flow Adj. Valve; w/Stop Valve, Return Unit Flow Switch: Remote Sensor Unit, Return Unit Flow Range: 5 to 40 L/min, Return Unit Components: w/o Flow Adj. Valve; w/Stop Valve, Supply/Return Port Size: 3/4, Return Unit Flow Switch Output Specifications: Out 1: Analog 4 to 20 mA; Out 2: Flow
Dia 25 2t.2 24.5 30 25 42.5 3t.5 2t23 106 32 39.2 45 40.5 54.8 46.2 77 58.2 3920 196 40 54.5 62.5 56.4 76.3 64.2 107 80.9 5450 272.5 50 85 97.7 88 I l 9 100.2 t67.3 126.4 8500 63 135 155 t39.8 r89 t59.2 265.5 200.5 13500 675 80 zl7.'
Dia 25 2t.2 24.5 30 25 42.5 3t.5 2t23 106 32 39.2 45 40.5 54.8 46.2 77 58.2 3920 196 40 54.5 62.5 56.4 76.3 64.2 107 80.9 5450 272.5 50 85 97.7 88 I l 9 100.2 t67.3 126.4 8500 63 135 155 t39.8 r89 t59.2 265.5 200.5 13500 675 80 zl7.'
With surge voltage suppressor) 24 VAC 12 VDC 12 VDC 24 VDC Electrical option Other option Faston terminal 100 VAC 110 VAC 200 VAC 230 VAC DIN terminal (With surge voltage suppressor) 48 VAC 2G 2H 2V 2J 220 VAC 240 VAC 24 VAC 12 VDC 24 VDC 2K 2L 100 VAC 110 VAC 200 VAC 230 VAC 2M 2N 2P 2Q 2R 2S Conduit terminal (With surge voltage suppressor) 48 VAC 220 VAC 240 VAC 2W 24 VAC 12 VDC 24 VDC 2T
Stations: 2 Stations, Piping: U Side: Closed; D Side: Open, Thread Type: NPT, Supply Unit Components: w/Flow Adj. Valve; w/Stop Valve, Return Unit Flow Switch: Remote Sensor Unit, Return Unit Flow Range: 2 to 16 L/min, Return Unit Components: w/Flow Adj. Valve; w/Stop Valve, Supply/Return Port Size: 1/2, Return Unit Flow Switch Output Specifications: Out 1: Analog 4 to 20 mA; Out 2: Flow
Stations: 3 Stations, Piping: U Side: Closed; D Side: Open, Thread Type: NPT, Supply Unit Components: w/Flow Adj. Valve; w/Stop Valve, Return Unit Flow Switch: Remote Sensor Unit, Return Unit Flow Range: 2 to 16 L/min, Return Unit Components: w/Flow Adj. Valve; w/Stop Valve, Supply/Return Port Size: 1/2, Return Unit Flow Switch Output Specifications: Out 1: Analog 4 to 20 mA; Out 2: Flow
Stations: 4 Stations, Piping: U Side: Closed; D Side: Open, Thread Type: NPT, Supply Unit Components: w/Flow Adj. Valve; w/Stop Valve, Return Unit Flow Switch: Remote Sensor Unit, Return Unit Flow Range: 2 to 16 L/min, Return Unit Components: w/Flow Adj. Valve; w/Stop Valve, Supply/Return Port Size: 1/2, Return Unit Flow Switch Output Specifications: Out 1: Analog 4 to 20 mA; Out 2: Flow
Stations: 5 Stations, Piping: U Side: Closed; D Side: Open, Thread Type: NPT, Supply Unit Components: w/Flow Adj. Valve; w/Stop Valve, Return Unit Flow Switch: Remote Sensor Unit, Return Unit Flow Range: 2 to 16 L/min, Return Unit Components: w/Flow Adj. Valve; w/Stop Valve, Supply/Return Port Size: 1/2, Return Unit Flow Switch Output Specifications: Out 1: Analog 4 to 20 mA; Out 2: Flow
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector)
Solenoid: No.1 Solenoid, Body Size: 5 (20A), Style: 0 (Energized Open/N.C.), Option: D (BC6, Copper Body & Shading Coil, FPM Seal, Class H Coil), Port Size: 04 [1/2 (20A)], Thread: Rc, Voltage: 2 (200VAC 50/60HZ), Lead Wire: T (Conduit Terminal)
Solenoid: No.1 Solenoid, Body Option: 4 (15A), Style: 0 (Energized Open/N.C.), Option: S (Brass or BC6, Copper Body & Shading Coil PTFE (FPM)Seal, Class H Coil), Port Size: 04 [1/2 (10,15A)], Thread: Rc, Voltage: 2 (200VAC 50/60HZ), Lead Wire: T (Conduit Terminal)
Solenoid: -, Size: -, Style: -, Option: -, Suffix: -, Port Size: -, Thread: -, Voltage: -, Electrical Entry: -, Surge Suppressor: -, Built-in Full-wave Rectifier: -, 1: -, Bracket: -
Model: -, Orifice Size: -, Style: -, Fluid Option: -, Suffix: -, Port Size: -, Thread: -, Voltage: -, Lead Wire: -, Surge Suppressor: -, Rectifier: -, Bracket: -
Solenoid: No.1 Solenoid, Body Option: 15A, Style: Energized Open/N.C., Option: Brass or BC6, Copper Body & Shading Coil PTFE (FPM)Seal, Class H Coil, Port Size: 04 [1/2 (10,15A)], Thread: Rc, Voltage: 200VAC 50/60HZ, Lead Wire: Conduit Terminal, Surge Suppressor: -, Bracket: -
Solenoid: No.1 Solenoid, Body Size: 20A, Style: Energized Open/N.C., Option: BC6, Copper Body & Shading Coil, FPM Seal, Class H Coil, Port Size: 04 [1/2 (20A)], Thread: Rc, Voltage: 200VAC 50/60HZ, Lead Wire: Conduit Terminal, Surge Suppressor: -
Valve: None; Stop Valve: None, Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes)