Sensor Range: 1 [For Vacuum (0~-101kPa)], Port Size: 02 [R1/4 (M5 Female Thread)], Output Specification: 28 [Current Output (4~20mA) Type], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]
Sensor Range: 1 [For Vacuum (0~-101kPa)], Port Size: A2 (URJ 1/4), Output Specification: 28 [Current Output (4~20mA) Type], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]
Sensor Range: 1 [For Vacuum (0~-101kPa)], Port Size: TSJ 1/4, Output Specification: 28 [Current Output (4~20mA) Type], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]
Sensor Range: 1 [For Vacuum (0~-101kPa)], Port Size: Rc 1/8, Output Specification: 28 [Current Output (4~20mA) Type], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]
Sensor Range: 1 [For Vacuum (0~-101kPa)], Port Size: N02 [NPT 1/4 (w/M5 Female Thread)], Output Specification: 28 [Current Output (4~20mA) Type], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]
Sensor Range: 1 [For Vacuum (0~-101kPa)], Port Size: 01 [R 1/8 (w/M5 Female Thread)], Output Specification: 28 [Current Output (4~20mA) Type], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]
Sensor Range: 1 [For Vacuum (0~-101kPa)], Port Size: 02 [R1/4 (M5 Female Thread)], Output Specification: 28 [Current Output (4~20mA) Type], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]
Sensor Range: 1 [For Vacuum (0~-101kPa)], Port Size: URJ 1/4, Output Specification: 28 [Current Output (4~20mA) Type], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]
Sensor Range: 1 [For Vacuum (0~-101kPa)], Port Size: N01 [NPT 1/8 (w/M5 Female Thread)]
Sensor Range: 1 [For Vacuum (0~-101kPa)], Port Size: N01 [NPT 1/8 (w/M5 Female Thread)], Output Specification: -, Option: -
PSE561 and 562 are remote pressure sensors with an analog V or mA signal output. PSE56* sensors measure pressure of any liquid or gas non-corrosive to 316L stainless steel. PSE561 is for low vacuum (-101 to 0 kPa), while PSE563 is for compound pressure (-100 to 100 kPa). The accuracy and construction are suitable for general purpose applications.
PSE561 and 562 are remote pressure sensors with an analog V or mA signal output. PSE56* sensors measure pressure of any liquid or gas non-corrosive to 316L stainless steel. PSE561 is for low vacuum (-101 to 0 kPa), while PSE563 is for compound pressure (-100 to 100 kPa). The accuracy and construction are suitable for general purpose applications.
Specifications Series PSE200A PSE533 PSE543 PSE563 PSE573 PSE530 PSE540 PSE560 PSE570 Applicable SMC pressure sensor PSE550 PSE531 PSE541 PSE561 PSE532 PSE564 PSE574 PSE575 PSE576 PSE577 Rated pressure range 0 to 2 kPa 0 to 101 kPa 100 to 100 kPa 0 to 100 kPa 0 to 500 kPa 0 to 1 MPa 0 to 2 MPa 0 to 5 MPa 0 to 10 MPa Display/Set pressure range 0.2 to 2.1 kPa 10 to 105 kPa 105 to 105 kPa 10
0.2%F.S. or less, Enclosure: IP65, SENSOR, GENERAL FLUID, VACUUM, VACUUM SERIES, PSE531/PSE541/PSE561, JD, PSE5*1 VAC SWITCH 1/8PORT NPT, .66138 lb
. + PSE530 PSE540 PSE560 PSE570 PSE533 PSE543 PSE563 PSE573 12 to 24 VDC PSE531 PSE541 PSE561 Black OUT Applicable pressure sensor PSE532 (Current output) Load Blue DC(-) PSE300 series (PSE5##) PSE310 series (PSE5##-28) NOTE The direct current power supply to be used should be UL approved as follows: Circuit (of Class 2) which is of maximum 30 Vrms (42.4 V peak), with UL1310 Class 2 power
Sensor Range: 1 [For Vacuum (0~-101kPa)], Port Size: N01 [NPT 1/8 (w/M5 Female Thread)], Output Specification: 28 [Current Output (4~20mA) Type]
Sensor Range: 1 [For Vacuum (0~-101kPa)], Port Size: N01 [NPT 1/8 (w/M5 Female Thread)], Output Specification: 28 [Current Output (4~20mA) Type], Option: -
C2: 2 (SMC) C4: 4 (SMC) 9.1 (C6) 10.3 (C2, C4) D D 3/5 B 2 E 3/5 B 2 B 2 B 2 E B 2 27 (C2, C4) 25.8 (C6) A 4 A 4 A 4 1 P P 1 4 A 4 A S (Pitch of C2, C4) P = 6.5 One-touch fitting [1(P), 3/5(E) port] Applicable tubing: 8 (SMC) (Pitch of C6) P = 9 * Refer to page 97 for dimensions of external pilot and built-in silencer. * Refer to pages 65 to 68, 79, and 80 for dimensions when L6, b, and
(If not specifying dimension C2, indicate instead.)
(If not specifying dimension C2, indicate instead.)