Elbow type How to Order AS 2 2 1 1 F 01 06 S T Tamper proof Speed Controller requires a special tool for flow adjustment. Order separately with part number, AS-T-1. With seal Note) In case that connecting port is either M5 or 10-32 UNF thread, it is not available with seal. With gasket is provided as standard.
Type: Solenoid Valves, Application: Single Unit, Mounting Orientation: Direct, Voltage: DC12V, Specification: Standard, Actuation: [Single] Single, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: 2-Position Normally Closed, Pipe Port Type: NPTF, Port Size: 1/8, Pressure Rating(MPa): 0 to 1.0, Driving Type: Linear Motion Poppet, Seal Type: Soft Seal, Plumbing: Direct Plumbing
Type: Solenoid Valves, Application: Single Unit, Mounting Orientation: Direct, Voltage: DC12V, Specification: Standard, Actuation: [Single] Single, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: 2-Position Normally Closed, Pipe Port Type: NPTF, Port Size: 1/8, Pressure Rating(MPa): 0 to 1.0, Driving Type: Linear Motion Poppet, Seal Type: Soft Seal, Plumbing: Direct Plumbing
Valve Type: 31 (N.C. Body Ported), Voltage: 6 (12VDC), Electrical Entry: G (Grommet), Orifice Size: 16 (1.6mm), Port Size: 01 [Base Mount w/Sub-Plate 1/8(6A) or Body Ported 1/8(6A)], Thread Type: T (NPTF)
Valve Type: 31 (N.C. Body Ported), Voltage: 6 (12VDC), Electrical Entry: G (Grommet), Orifice Size: 23 (2.3mm), Port Size: 01 [Base Mount w/Sub-Plate 1/8(6A) or Body Ported 1/8(6A)], Thread Type: T (NPTF)
Valve Type: N.C. Body Ported, Voltage: 24VDC, Electrical Entry: Grommet, Orifice Size: 4mm, Port Size: 01 [Base Mount w/Sub-Plate 1/8(6A) or Body Ported 1/8(6A)], Thread Type: NPTF, Body/Seal Material: Body SUS, Seal FKM, Option: Foot Bracket
Body Ported), Voltage: 5 (24VDC), Electrical Entry: G (Grommet), Orifice Size: 40 (4mm), Port Size: 01 [Base Mount w/Sub-Plate 1/8(6A) or Body Ported 1/8(6A)], Thread Type: T (NPTF), Body/Seal Material: H (Body SUS, Seal FKM), Option: F (Foot Bracket)
Applicable cylinder bore size (mm) Elbow type Universal type Port size Metric size Inch size 3.2 4 6 8 10 12 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" AS121F-M5 AS131F-M5 6, 10, 16, 20 M5 x 0.8 AS221F-01 AS231F-01 20, 25, 32 R 1/8 AS221F-02 AS231F-02 20, 25, 32, 40 R 1/4 AS321F-02 AS331F-02 40, 50, 63 R 1/4 AS321F-03 AS331F-03 40, 50, 63 R 3/8 AS421F-04 AS431F-04 63, 80, 100 R 1/2 AS121F-U10/
Type 40/Type 41 How to Order SS3YJ7 40 05 01 Applicable solenoid valve SYJ714SYJ714MSYJ724SYJ724MApplicable blanking plate assembly SYJ700-10-2A R port 1/4 R port 1/8 P, R port thread type Manifold type Stations 40 41 Type 40 Type 41 Nil Rc G NPT NPTF 2 stations : 20 stations 02 : 20 A A F N T A A 01 1/8 A port size P port 1/8 P port 1/4 Courtesy of Steven Engineering, Inc.-230 Ryan Way,
Type: Solenoid Valves, Application: Single Unit, Mounting Orientation: Direct, Voltage: DC12V, Specification: Standard, Actuation: [Single] Single, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: 2-Position Normally Closed, Pipe Port Type: NPT, Port Size: 1/8, Pressure Rating(MPa): 0 to 1.0, Driving Type: Linear Motion Poppet, Seal Type: Soft Seal, Plumbing: Direct Plumbing
Valve Type: N.C. Body Ported, Voltage: 12VDC, Electrical Entry: Grommet, Orifice Size: 4mm, Port Size: 01 [Base Mount w/Sub-Plate 1/8(6A) or Body Ported 1/8(6A)], Thread Type: Rc, Body/Seal Material: Body SUS, Seal FKM, Option: -
Body Ported), Voltage: 6 (12VDC), Electrical Entry: G (Grommet), Orifice Size: 40 (4mm), Port Size: 01 [Base Mount w/Sub-Plate 1/8(6A) or Body Ported 1/8(6A)], Thread Type: N (NPT), Body/Seal Material: H (Body SUS, Seal FKM)
Body Ported), Voltage: 6 (12VDC), Electrical Entry: G (Grommet), Orifice Size: 40 (4mm), Port Size: 01 [Base Mount w/Sub-Plate 1/8(6A) or Body Ported 1/8(6A)], Thread Type: Rc, Body/Seal Material: H (Body SUS, Seal FKM)
or less 36 or less 40 or less 36 or less 40 or less 40 or less 45 or less 50 or less 15 or less 20 or less 70 or less 80 or less 70 or less 80 or less 70 or less 80 or less 80 or less Single 2-position 5 (R1) 3 (R2) Double 1 (P) N.C.
Type: Solenoid Valves, Application: Single Unit, Mounting Orientation: Direct, Voltage: DC24V, Specification: Standard, Actuation: [Single] Single, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: 2-Position Normally Closed, Pipe Port Type: NPTF, Port Size: 1/8, Pressure Rating(MPa): 0 to 1.0, Driving Type: Linear Motion Poppet, Seal Type: Soft Seal, Plumbing: Direct Plumbing
Body Ported), Voltage: 5 (24VDC), Electrical Entry: G (Grommet), Orifice Size: 40 (4mm), Port Size: 01 [Base Mount w/Sub-Plate 1/8(6A) or Body Ported 1/8(6A)], Thread Type: T (NPTF)
SOLENOID VALVE, PROPORTIONAL VALVE, F47, 0.108 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VALVE, PROPORTIONAL, VALVE, PVQ PROPORTIONAL VALVE, 2H, PVQ NO SIZE RATING, .25535 lb
Blanking plate with 2 screws and gasket L dimension 39 498 38 485.5 37 473 36 460.5 35 448 34 435.5 33 423 32 410.5 31 398 No. 40 510.5 L dimension 4-12-16