L N VQ110VQ110YVQ110 ZQ1-VQ120Model Push-locking type Non-locking push type / Locking type (Tool type) Manual override Non-locking push type / Locking type (Tool type) Rated coil voltage 12, 24 VDC, 100, 110, 200, 220 VAC 12, 24 VDC, 100, 110, 200, 220 VAC 12, 24 VDC 12, 24 VDC DC 100 VAC 110 VAC 200 VAC 220 VAC 1 W 1 W 0.5 W 0.6 VA (6 mA) 0.65 VA (5.9 mA) 1.2 VA (6 mA) 1.3 VA (5.9 mA) Grommet
Coil rated voltage 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Wiring Specifications The lead wires are connected to the valve as shown below. Connect each to the power supply side.
x 0.35 x 19 M3 x 0.35 x 23 M3 x 0.35 x 24 M3 x 0.35 x 28 M3 x 0.35 x 68 M3 x 0.35 x 72 M3 x 0.35 x 73 M3 x 0.35 x 77 y u Components Ejector unit + Vacuum switch/Filter unit i o For nozzle size 10, 13, 15 M3 x 0.35 x 84 4 [For ZSE4 spec.]
However, for 400 VAC, model should also be selected based on the amount of processed air of 380 VAC regarding IDFA100F to 150F. (Correction factor is based on the rated conditions of 380 VAC, so when the factor of rated conditions of 400 VAC is inputted , the amount of processed air of 400 VAC can be found.)
CQ-M3 x 35L x 40L CQ-M3 x 40L x 45L CQ-M5 x 40L x 45L CQ-M5 x 40L x 45L CQ-M5 x 40L x 45L CQ-M5 x 45L x 50L CQ-M6 x 55L x 60L Cylinder model Mounting bolt part no.
L1 L21 L3 M1 d2 M3 Q1 D22 2 x F VAC.
Rated voltage 24 VDC 12 VDC 100 VAC 200 VAC 110 VAC (115 VAC) 220 VAC (230 VAC) Voltage symbol 24 VN 12 VN 100 VN 200 VN 110 VN 220 VN Part no.
(Fixed SI unit [l/min, or l, m3 or m3 x 103] will be set for switch types without an unit switching function.)
Coil voltage 1 2 3 4 5 6 100 VAC (50/60 Hz) 200 VAC (50/60 Hz) 110 VAC [115 VAC] (50/60 Hz) 220 VAC [230 VAC] (50/60 Hz) 24 VDC 12 VDC Note) For sub-plate part no., refer to page 967.
EX9 FU05 Fuse Model EX9-FU05 Applicable model EX250-IE Rated current 0.5 A Rated insulation capacity 48 VAC/DC 50 A 0.36 Fuse resistance value t End plate (Input side) EX250 EX250-EA1 EA 1 Mounting specification 64.4 1 2 Direct mounting DIN rail mounting Mounting hole for 2 x M4 12.5 18 Accessory Hexagon socket head cap screw (M3 x 10): 2 pcs. 66 10 60 EX 13.2 75 18 EX250-EA2 64.4 M4 clamp
x 48.5 (Flat nickel plated) Mounting screw tightening torques ARBY5000 SX5000-57-5 M2: 0.15Nm M3: 0.6Nm ARBY7000 New!
(50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Other 1 2 3 4 5 6 9 Note) Option Note) Except large flow type.
(50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Other 1 2 3 4 5 6 9 Note) Option Note) Except large flow type.
(50/60 Hz) 200 VAC (50/60 Hz) 110 VAC (50/60 Hz) 220 VAC (50/60 Hz) 24 VDC 12 VDC Other 1 2 3 4 5 6 9 Note) Option Note) Except large flow type.
For manifold type 30, 31 VP Standard type (Cv: 0.008) SY1 3 5 L 1 M3 : Body ported VG VP Standard type (Cv: 0.008) 5 1 SY1 4 M : Base mounted S070 3 port VQ Port size Rated voltage For DC Nil: Without sub-plate M3: With sub-plate VKF 5 6 V S R 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC VQZ VZ Sub-plate style For manifold type S41 For AC (50/60 Hz) 1 2 3 4 100 VAC 200 VAC VS (With gasket and screws)
Load factor 1 = m3 / m3 max = 7.025 / 22.5 = 0.31 m3 M2: Moment Z M2 max (from 2 of graph MY2H / M2) = 19.5 (Nm) . M2 = m3 x g x Z = 7.025 x 9.8 x 37.8 x 103 = 2.60 (Nm) Load factor 2 = M2 / M2 max = 2.60 / 19.5 = 0.13 m3 M2 5 Series E-MY2 Selection Example cont. X M3: Moment M3 max (from 3 of graph MY2H / M3) = 19.5 (Nm) .
, 50/60 Hz 200 VAC, 50/60 Hz 110 to 120 VAC, 50/60 Hz 4 220 VAC, 50/60 Hz 5 6 24 VDC 12 VDC 7 240 VAC, 50/60 Hz 9 Other Option Body Option Pilot type 0 1 Standard Direct manual override R Internal pilot External pilot Nil Option How to Order Pilot Valve Assembly Option SF4 F 1 22 Coil rated voltage 1 100 VAC, 50/60 Hz 2 200 VAC, 50/60 Hz 3110 to 120 VAC, 50/60 Hz 4 220 VAC, 50/60 Hz 5
BQ-2 1.5 M3 x 0.5 x 8 l BQ-1 1 D-A7 D-A8 D-F7 D-J7 Auto switch mounting screw BQ2-012 5 M3 x 0.5 x 10 l BQ-2 1 BBA2 BQP1-050 16 Auto switch mounting nut (Square nut) BQ-1 1 M3 x 0.5 Auto switch mounting nut (Convex type) BQ-2 1 M3 x 0.5 Note) When using BQ-1, BBA2 may be used by itself.
: Yawing M1: Pitching y x M2: Rolling Static moment Ceiling mounting Horizontal mounting Wall mounting M1 M2 M2 M1 M2 M3 y X x Y y z X x Y X x Z m1 x g m2 x g m3 x g Vertical mounting Mounting orientation Horizontal Ceiling Wall Vertical m1 m2 m3 m4 Static load m M3 M1 m1 x g x X m2 x g x X m4 x g x Z Static moment M1 m1 x g x Y m2 x g x Y m3 x g x Z y z M2 z Y m3 x g x X m4 x g x Y M3 m4
Note) Air flow capacity (scfm [ANR]) Applicable air compressor (kW) 50 Hz Model Power supply voltage (Frequency) Port size 60 Hz IDF1E 3.53 4.24 0.75 Single-phase 100 VAC (50 Hz) Single-phase 100/110 VAC (60 Hz) IDF2E 7.06 8.30 1.5 Rc3/8 IDF3E 11.3 13.1 2.2 IDF4E 18.4 20.1 3.7 Rc1/2 Single-phase 100/200 VAC (50 Hz) IDF6E 26.5 29.0 5.5 Single-phase 100/110 VAC, 200/220 VAC (60 Hz) IDF8E 43.1