Mitsubishi Electric Corporation Yaskawa Electric Corporation 02 03 04 05 05 5m Cable length 2m 3m 4m 5m Applicable cables Model Manufacturer part no.
Note Power supply/Output connection cable Description ZS-28-A D Mounting screw (M3 x 8L) (Accessory) Bracket ZS-28-B With M3 x 5L (2 pcs.) Sensor connector ZS-28-C 1 pc. Panel mount adapter Panel mount adapter ZS-27-C With M3 x 8L (2 pcs.) ZS-27-D With M3 x 8L (2 pcs.)
x 10-3 = 2.81 (Nm) Load factor 2 = M2/M2 max = 2.81/50 = 0.06 m3 M2 9 Model Selection Series MY2 Calculation of Guide Load Factors X M3: Moment M3 max (from 3 of graph MY2H/M3) = 60 (Nm) M3 = m3 x g x X = 7.525 x 9.8 x 140.1 x 10-3 = 10.33 (Nm) m3 M3 Load factor 3 = M3/M3 max = 10.33/60 = 0.17 5 Calculation of load factor for dynamic moment Z Equivalent load FE at impact 1.4 100 1.4 100
(M3 x 40) VZ1000-11-4SV3000-69A : Manifold stations Manifold Specification Sheets Refer to DIN rail dimension tables on page 85.
SY11 A 3 4 M3 x 0.5 M3 x 0.5 100 kPA to 0 0.22 100 kPA to 0.6 Large flow 0 to 0.7 N.C. SY13(A): 15 SY14(A): 26 (14) SY13(A): 13 SY14(A): 24 (12) (1) SY12 3 4 M3 x 0.5 M3 x 0.5 100 kPA to 0.6 0.14 100 kPA to 0 Standard 0 to 0.7 N.O. (1) SY12 A 3 4 M3 x 0.5 M3 x 0.5 100 kPA to 0.6 100 kPA to 0 0.22 Large flow 0 to 0.7 N.O.
Coordinates and Moments z M3: Yawing M1: Pitching y x M2: Rolling Static moment Ceiling mounting Horizontal mounting Wall mounting M1 M2 M2 M1 M2 M3 y X x Y y z X x Y X x Z m1 x g m2 x g m3 x g Vertical mounting Mounting orientation Horizontal Ceiling Wall Vertical m1 m2 m3 m4 Static load m M3 M1 m1 x g x X m2 x g x X m4 x g x Z Static moment M1 m1 x g x Y m2 x g x Y m3 x g x Z y z M2 z Y
X 25 l M3 X 30 l M3 X 35 l M3 X 40 l M3 X 45 l M3 X 50 l M3 50 55 60 65 70 25 30 35 40 45 50 6.5 6.5 Secure the cylinder by using Secure the cylinder by using the OA screws that are the OA screws that are provided with the cylinder provided with the cylinder tube. tube.
SY3000 SY3000-23-4 (M2 x 21) M3 x 26 (Flat nickel plated) M4 x 31 (Flat nickel plated) SY3000-11-24 SY5000 SY5000-11-10 SY7000 SY7000-11-9 Note 2) For SY9000, the SUP port is only available on the end plate side. SY9000-18-2 (M3 x 42) SY9000 SY9000-11-1 Plug (white) Insert into unused cylinder ports and SUP/EXH ports. The minimum order quantity is 10 pieces. Order in multiples of 10.
L (Example) C73CL 5m . Z (Example) C73CZ None .
T-brackets T-nuts Model LC1-1-L5 (Weight: 16.0g) Model LC1-1-L3 (Weight: 15.5g) M (Weight: 10.0g) M5 M3 17.5 17.5 17.5 7.5 18 12 11 M Model 20 7.5 7.5 21 LC1-1-N3 M3 x 0.5 29 30 LC1-1-N5 M5 x 0.8 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Controller Connectors
x 0.5 3.5 M3 x 0.5 M3 x 0.5 16 50.5 10.8 24.4 9.4 25 9.5 2H9 2 M3 x 0.5 4.8 20 22.5 2H9 2 11 2H9 2 M3 x 0.5 3.5 M4 x 0.7 M3 x 0.5 18 56 13.4 26.2 11.3 28 10 2H9 2 M3 x 0.5 5.3 21 24.5 2H9 2 11.5 2H9 2 M3 x 0.5 3.5 M5 x 0.8 M3 x 0.5 20.5 60 15.2 31 11.8 30.5 12 2H9 2 M3 x 0.5 5.3 25 27 2H9 2 13.5 2H9 2 M4 x 0.7 4.5 M6 x 1 M5 x 0.8 23 73.5 15.4 37.4 14.9 34.5 14 3H9 3 M4 x 0.7 6.5 29 32.5
(ANR) oil mist concentration (before saturated with hydraulic fluid: 0.01mg/m3 (ANR) or less, approx. 0.008ppm ) Note 1) Pressure gauge connection threads are not required for the regulator with a square embedded type pressure gauge (AWD20 to 40).
2.a VALVES VALVES SERIES PAGE NUMBER SX3000 / SX5000 2.1 SOLENOID VALVE SY100 2.5 3/2 DIRECT ACTING / SOLENOID SPRING VALVE M3 PORTED SY3000/5000/7000 2.8 BODY PORTED SOLENOID VALVE SY3000/5000/7000 2.13 BASE MOUNTED SOLENOID VALVE VQ100 2.19 3/2 DIRECT ACTING / SOLENOID SPRING VALVE M3-M5 PORTED VQ0 2.21 5 PORT METAL/RUBBER SEAL ULTRA HIGH SPEED SOLENOID VALVE VQ1000 2.26 5 PORT METAL/RUBBER
x 0.93 x 1 x 0.88) = 0.51 m3/min 3 Selecting a model According to the corrected air flow capacity of 0.43 m3/min, IDF4E will be selected which air flow capacity is 0.52 m3/min at 50 Hz.