or less 6.5 or less 5ms or less 5ms or less Response time (2) 1W (42mA) 0.7W (29mA) (3) 1W (42mA) 24V DC 1W (83mA) 0.7W (29mA) (3) 1W (83mA) 12V DC Clean Series Power consumption (Current) 0.6VA (6mA) 0.5VA (5mA) 100V AC Clean series is available for both standard and option specifications. 0.55VA (5mA) 0.65VA (5.9mA) 110V AC 1.0VA (5mA) 1.2VA (6mA) 200V AC How to Order Valve 10-VQ110l-l
Function: 1 (2 Position Single), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: M (M Plug Connector w/Lead Wire 0.3m), Surge Suppressor: S (Surge Suppressor), Manual Override: None, Port Size: C6 (ø6 One-touch Fitting)
Type of Actuation: 1 (2 Position Single), Manifold Type: 20 (Body Ported Plug-in Integrated), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: M (M Plug Connector w/Lead Wire 0.3m), Lead Wire Length: None, Surge Suppressor: S (Surge Suppressor), Manual Override: Non-locking Push Style, A, B Port Size: C6 (Body Ported ø6 One-touch Fitting)
Type of Actuation: 1 (2 Position Single), Manifold Type: 20 (Body Ported Plug-in Integrated), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: M (M Plug Connector w/Lead Wire 0.3m), Lead Wire Length: None, Surge Suppressor: S (Surge Suppressor), Manual Override: Non-locking Push Style, A, B Port Size: C6 (Body Ported ø6 One-touch Fitting)
Type: Solenoid Valves, Application: Single Unit, Mounting Orientation: Direct, Voltage: DC24V, Specification: Standard, Valve Type: 5-Port Valve, Actuation: [Single] Single, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: 2-Position Normally Open, Pipe Port Type: One-Touch Plumbing, Port Size: -, Connecting Tube Diameter: Ø6, Pressure Rating(MPa): 0.15 to 0.7, Driving
Function: 2 (2 Position Double), Pilot: Internal Pilot, Back Pressure Check: None, Voltage: 5 (24VDC), Common: +COM, Lead Wire: M (M Plug Connector w/Lead Wire 0.3m), Surge Suppressor: S (Surge Suppressor), Switch: None, Manual Override: Non-locking Push Style, Port Size: C6 (ø6 One-touch Fitting)
Function: 2 Position Double, Pilot: Internal Pilot, Back Pressure Check: None, Voltage: 24VDC, Common: +COM, Lead Wire: M Plug Connector w/Lead Wire 0.3m, Surge Suppressor: Surge Suppressor, Switch: None, Manual Override: Non-locking Push Style, Port Size: ø6 One-touch Fitting
Type of Actuation: 2 Position Single, Manifold Type: Body Ported Plug-in Integrated, Pilot: Internal Pilot, Specifications: Standard, Voltage: 24VDC, Electrical Entry: M Plug Connector w/Lead Wire 0.3m, Lead Wire Length: None, Surge Suppressor: Surge Suppressor, Manual Override: Non-locking Push Style, A, B Port Size: Body Ported ø6 One-touch Fitting, Thread: -, Option: -
Type of Actuation: 3 Position Closed Center, Manifold Type: Body Ported Plug-in Integrated, Pilot: Internal Pilot, Specifications: Standard, Voltage: 24VDC, Electrical Entry: M Plug Connector w/Lead Wire 0.3m, Lead Wire Length: None, Surge Suppressor: Surge Suppressor, Manual Override: Non-locking Push Style, A, B Port Size: Body Ported ø6 One-touch Fitting, Thread: -, Option: -
Type of Actuation: 2 Position Single, Manifold Type: Body Ported Plug-in Integrated, Pilot: Internal Pilot, Specifications: Standard, Voltage: 24VDC, Electrical Entry: M Plug Connector w/Lead Wire 0.3m, Lead Wire Length: None, Surge Suppressor: Surge Suppressor, Manual Override: Non-locking Push Style, A, B Port Size: Body Ported ø6 One-touch Fitting, Thread: -, Option: -
Type of Actuation: 3 (3 Position Closed Center), Manifold Type: 20 (Body Ported Plug-in Integrated), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: M (M Plug Connector w/Lead Wire 0.3m), Lead Wire Length: None, Surge Suppressor: S (Surge Suppressor), Manual Override: Non-locking Push Style, A, B Port Size: C6 (Body Ported ø6 One-touch Fitting)
Response speed: 5ms or less , Proof pressure: 500 kPa , Low flow rate range , Output: 1 to 5V analog (non-linear) , Piping specification: M5 female threads, Weight 10g (not including the lead wire) DIGITAL FLOW SWITCH. Flow Sensor for Air. 10.00000 lb. F29.
V O Speed Max. 10ms ON OFF BUSY ON OFF BUSY Max. 30ms Max. 60ms V O Speed Timing for alarm reset Response time with respect to controller input signals ON OFF ALARM -RESET Max. 5ms The following factors exist for delay of response with respect to controller input signals.
Response speed: 5ms or less , Proof pressure: 500 kPa , Low flow rate range , Output: 1 to 5V analog (non-linear) , Piping specification: M5 female threads, Weight 10g (not including the lead wire), FLOW SWITCH, INSTRUMENTATION, IFW/PFW FLOW SWITCH, 2X, IFW/PFW NO SIZE ALL OTHER, .22312 lb
V O Speed Max. 10ms ON OFF BUSY ON OFF BUSY Max. 30ms Max. 60ms V O Speed Timing for alarm reset Response time with respect to controller input signals ON OFF ALARM -RESET Max. 5ms The following factors exist for delay of response with respect to controller input signals.
V O Speed Max. 10ms ON OFF BUSY ON OFF BUSY Max. 30ms Max. 60ms V O Speed Timing for alarm reset Response time with respect to controller input signals ON OFF ALARM -RESET Max. 5ms The following factors exist for delay of response with respect to controller input signals.
V O Speed Max. 10ms ON OFF BUSY ON OFF BUSY Max. 30ms Max. 60ms V O Speed Response time with respect to controller input signals Timing for alarm reset ON OFF ALARM -RESET Max. 5ms The following factors exist for delay of response with respect to controller input signals.
V O Speed Max. 10ms ON OFF BUSY ON OFF BUSY Max. 30ms Max. 60ms V O Speed Timing for alarm reset Response time with respect to controller input signals ON OFF ALARM -RESET Max. 5ms The following factors exist for delay of response with respect to controller input signals.
Timing for stop by ALARM-RESET during operation Timing for home position return ON OFF SET -UP ALARM -RESET ON OFF max 5ms max 25ms ON OFF BUSY V O Speed max 20ms max 15ms V O Speed Home position return speed Creeping speed BUSY ON OFF ON OFF SET -ON BUSY-OFF timing is controlled by actuator deceleration.
OUT2 setting/(CH1 only) MPa or kPa OUT1 OUT2 CH 1 2 3 4 PRESSURE Normally Open Normally Closed SET SET 8 Series PSE Operation : Initial Setting 4 Response time setting MPa kPa OUT1 OUT2 CH 1 2 3 4 PRESSURE 5ms 20ms 160ms 640ms SET Press SET button.