SMC Corporation of America
Elite Part Number Search
Search Results "SYJ5323-5H-C6-Q"

Ordering example Double solenoid (24 VDC) 10-SZ3260-5LOZ-C6(-Q) (3 sets) SUP/EXH block assembly (U side mounting) Single solenoid (24 VDC) 10-SZ3160-5LOZ-C6(-Q) (2 sets) Manifold base (5 stations) 10-SS5Z3-60S6BD-05U(-Q) SI unit part no. LOCK FREE SI unit specifications SI unit part no.

(-Q) 10-SS3YJ3-42(-Q) 10-SS3YJ3-S42(-Q) Applicable base Sub-plate 10-SS3YJ3-41(-Q) 10-SS3YJ3-S41(-Q) 10-SS3YJ3-42(-Q) 10-SS3YJ3-S42(-Q) Applicable base 10-SS3YJ3-20(-Q) Manifold base Manifold base Manifold base Note) Add suffix -Q for the CE-compliant product.

, C8 C6: One-touch fitting assembly for 6 B B B 4 2-Rc 1/8, 1/4, C6, C8 C6: One-touch fitting assembly for 6 C8: One-touch fitting assembly for 8 VQD 2 A C8: One-touch fitting assembly for 8 B 23 P = 22 L1 L2 L3 (For C6, C8) ( 9.5) DIN rail clamp screw 80 ( 9.5) 2-M4 mounting hole (For C6, C8) (For C6, C8) 4.5 2-M6 mounting hole IN IN IN IN 5.5 80 6.5 (40) 69.5 58 37.5 39.5 Residual pressure

Function: 3 (3 Position Closed Center), Piping: 2 (Body Ported), Exhaust: 3 (Common), Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: H (Grommet Lead Wire 0.6m), Surge Suppressor: None, Manual Override: None, Port Size: M5 (Body Ported M5X0.8)

Type: Solenoid Valves, Application: Single Unit, Mounting Orientation: Direct, Voltage: DC24V, Specification: Standard, Valve Type: 5-Port Valve, Actuation: -, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: 3-Position Closed Center, Pipe Port Type: M, Port Size: M5, Connecting Tube Diameter: -, Pressure Rating(MPa): 0.15 to 0.7, Driving Type: Pilot Type Spool, Pilot

Connector for unit (Plug) 6 y t y t EX600-DXlB EX600-DYlB EX600-DXlCl q w q w e q w er e y t y t y t EX600-DXlD EX600-DXlE EX600-DYlE EX600-DMlE EX600-DXlF EX600-DYlF EX600-DMlF Analog Unit q w e q w e No.

Applicable individual SUP spacer assembly SYJ7000-16-2A 42 Type (5 Port/Base mounted) How to Order SS5YJ7-42-05 -C6 Applicable interface regulator ARBYJ7000-00-P A, B port side Stations C6(6 One-touch fitting) C6 2 stations 02 P port Rc(PT)1/4 C8(8 One-touch fitting) C8 : : 20 stations 20 A, B port C6, C8 R port Rc(PT)1/4 Note) For more than 8 stations, supply air to both sides of "P" port

Specifications External power supply Q 0.1 A F, H, J1, J2, Q, R1, R2, V EX140-SDN1 DeviceNet, CompoBus/D (OMRON Corp.)

C8 1/8 C6 C8 1/8 1/8 C6 C8 SS5YJ7-20 Body ported SYJ72 for internal pilot SS5YJ7-21 SS5YJ7-40 SS5YJ7-41 SS5YJ7-42-C6 SS5YJ7-42-C8 Base mounted SYJ74 for internal pilot Note) Value at manifold base mounted, 2 position single operating How to Order Manifold (Example) Instruct by specifying the valves and blanking plate assembly to be mounted on the manifold along with the manifold base model

Symbol Description Surface treatment Note Material A VCC12(D)-00 For VVCC12-1A-02FC4 C6 PPS resin C4 C6 VVCC12-1A-02F Pilot port C4: 4 piping C6: 6 piping Manifold block assembly for 2 port valve Manifold block q Hard anodized containing PTFE For VVCC12-1G-02FC4 C6 Aluminum C O-ring Special FKM w C4 C6 VVCC12-1G-02F Pilot port C4: 4 piping C6: 6 piping Manifold block assembly for gate

A B Effective orifice(mm2 Weight (g) ) E H M-5H-4 M-5H-6 15.5 16.5 8.5 9.5 7 8 1.8 2.5 7 8 2.1 4.0 2.7 3.9 6.5 8.5 91 Series M Miniature Fittings M3, R(PT) 1/8, M5 Series M5 Hose elbow: M-5HL-4, -6 Part No. Effective orifice(mm2 Weight (g) ) F E D C B A M-5HL-4 M-5HL-6 6.5 8.5 1.4 2.4 4.4 5.2 1.8 2.5 7 8 8.5 9.5 12.5 13.5 16.5 17.5 Hose elbow: M-5HLH-4, -6 Part No.

T I O N A C C E S S O R I E S S E R I E S N C Q 2 / C Q 2 C O I L S C R A P E R X C 3 5 O P T I O N Air XC35 D (N)CQ2 Bore Size 32, 40, 50, 63, 80, 100 Fluid S T R O K E M O U N T I N G B O R E S I Z E Thread Pitch M3 0.5 A C C E S S O R I E S M O U N T I N G K I T S S E R I E S N C Q 2 / C Q 2 A C C E S S O R I E S M O U N T I N G B O L T F O R S E R I E S N C Q 2 / C Q 2 M5 0.8 M6 1 M8

How to Order Manifold Tie-rod base 10-SS5V 1 Q D U 05 10S6 C6 Enclosure Series 1 2 3 W IP40 IP67 Nil 10-SV1000 10-SV2000 10-SV3000 Mounting Nil Direct mounting DIN rail mounting (With DIN rail) DIN rail mounting (Without DIN rail) D D0 Note 1) D3 D20 SI Unit 0 Q N V ZE D Without SI Unit DeviceNet PROFIBUS DP CC-Link EtherNet/IP EtherCAT For 3 stations When a longer DIN rail is desired than

VQC4000 VVQC4000-2A-1 Thread type Nil F T Rc G NPT/NPTF 22 Manifold Specification Sheet Series VQC1000: Base-Mounted Type/Plug-in Unit q How to order manifolds VV5QC 1 1 08 FD1 B C6 F P T Kit / / 1 2 3 8 VV5QC 1 1 08 SDQ B C6 S Kit Fill out for I/O serial kit only.

Body Resin SYJ q (A) 2 Spool valve Aluminum/NBR w e r Pilot valve VK 1 (P) 3 (R) Port plug Resin/NBR VVQZ100-CP VZ VT VQZ200/300 VT Metal seal Rubber seal VP VG q r w e q r w e VP VQ VQZ N.C. N.C. VZ (A) 2 (A) 2 VS 1 (P) 3 (R) 1 (P) 3 (R) q r w e q r w e N.O. N.O. (A) 2 (A) 2 1 (P) 3 (R) 1 (P) 3 (R) Component Parts No.

Manifold Specifications SV1000 SV2000 SV3000 SV4000 Applicable series Manifold type 1 (P: SUP)/3, 5 (E: EXH) type Valve stations (maximum) Max. number of solenoids Tie-rod base manifold Common SUP, EXH 20 stations 32 points 1(P), 3/5(E) port C8, N9 C3, C4, C6 N1, N3, N7 C10, N11 C4, C6, C8 N3, N7, N9 C12, N11 C6, C8, C10 N7, N9, N11 C12, N11, 03 C8, C10, C12 N9, N11, 02, 03 Port size 4(A)

Back cover 8 2-Color Display Digital Flow Switch RoHS PF2M7 Series How to Order PF2M7 10 C6 A M Integrated display q r t y u i w e q Rated flow range e Port size Piping variations 01 0.01 to 1 L/min 02 0.02 to 2 L/min 05 0.05 to 5 L/min 10 0.1 to 10 L/min 25 0.2 to 25 L/min 50 0.5 to 50 L/min 11 1 to 100 L/min 21 2 to 200 L/min With One-touch fitting Female thread C4*2, C6, C8, N7 01, 02,

SX3000 (Metric size) C4: With One-touch fitting for 4 C6: With One-touch fitting for 6 SX5000 (Metric size) C4: With One-touch fitting for 4 C6: With One-touch fitting for 6 C8: With One-touch fitting for 8 (Inch size) N3: With One-touch fitting for 5/32" N7: With One-touch fitting for 1/4" SX5000-50-1A-C6 SX3000-50-1AManifold block assembly q (Inch size) N3: With One-touch fitting for 5/

Fit the grooved part of gasket w into the flange part of case q. b. Place element e in case q. Element e must be positioned at the center of case q. c. Set clamp ring t to case q. The tapered part of clamp ring t must be facing downward. d. Set seal part of the element e to the cover r while the flange part of case q is being placed on clamp ring t. e.