SMC Corporation of America
Elite Part Number Search
Search Results "VQ7-6-FG-D-1A03"

/A80C 12 10 11 12 12 10 D-A79W 16 14 14 13 13 13 D-A9/A9V 11.5 9.5 9.5 9.5 D-F7/J79 D-F7V/J79C D-F7W/F7WV D-J79W/F7NTL D-F7BAL/F7BAVL/F79F 6.5 6 6 6 5.5 5.5 D-M9/M9V D-F9W/F9WV D-F9BAL 4.5 4.5 4.5 4.5 6 5.5 5.5 5.5 Since this is a guideline including hysteresis, not meant to be guaranteed.

Auto Switch Internal Circuit D-A90 (V) Contact protection box OUT () Brown Reed switch Unit: g Weight Table CD-P11 OUT () Blue CD-P12 D-A90 D-A90V D-A93 D-A93V D-A96 D-A96V Model Lead wire length: 0.5 m 6 6 6 6 8 8 D-A93 (V) Lead wire length: 3 m 30 30 30 30 41 41 LED diode Brown OUT (+) Brown Contact protection box Resistor Unit: mm Dimensions Reed switch Zener diode CD-P11 D-A90/D-A93/D-A96

RESET GND FG Connect to GND of the counter cable. RESET Reset signal is output. Connect to RESET of the counter cable. FG FG terminal. Connect to FG of the counter cable. 6.2 Counter plug wiring The wiring of the counter cable (LATH3-) and Multi-counter (CEU5) is shown below. Refer to the Multi-counter (CEU5) operation manual for further details.

Turn ON No. 3 and No. 6, and (c) Differential input R3 = 120 turn OFF the others. ON ON ON 1 2 3 4 5 6 1 2 3 4 5 6 1 2 3 4 5 6 (a) Open collector input (24 V) (b) Open collector input (5 V) (c) Differential input 36 - (4) Pulse input circuit example i.

(Brown) +24 V TD+ TD0 V INPUT OUTPUT DA DB DG SLD FG COM A Pressure welding for branch connector The method of pressure welding for branch connector is explained. (1)Components Internal circuit +24 V RD+ RD0 V FG Insulating cap Brown Black White Blue DC-DC converter (Insulation) Pin no. display Power supply for output +24 V TD+ TD0 V +24 V 0 V INPUT OUTPUT COM D Power supply for input and

AC200230V AC100120V 40 AC100120V 6 AC200230V L 1 L 1 PE L 2 2-M5 2-M5 L 2 L 3 CNP1 CNP1 N N P 1 P 1 P 2 P 2 M4 1.2[Nm] P P C C CNP2 D CNP2 D L 11 L 11 L 21 L 21 U U CNP3 V CNP3 V M5 3.24[Nm] W W 11 2 11 (2) LECSC-S8 [mm] 40 6 5 6 6 (80) 170 CNP1 () CN1 CNP2 CNP3 6 (68) (25.5) MR-J3BA MR-J3BAT 1.0[kg] .

Range Auto switch model Bore size (mm) 12 20 32 40 50 63 D-A7/A80 D-A7H/A80H D-A73C/A80C 12 10 11 12 12 10 D-A79W 16 14 14 13 13 13 D-A9/A9V 11.5 9.5 9.5 9.5 D-F7/J79 D-F7V/J79C D-F7W/F7WV D-J79W/F7NTL D-F7BAL/F7BAVL/F79F 6.5 6 6 6 5.5 5.5 D-M9/M9V D-F9W/F9WV D-F9BAL 4.5 4.5 4.5 4.5 6 5.5 5.5 5.5 Since this is a guideline including hysteresis, not meant to be guaranteed.

mm) Applicable bore size (mm) D C d D C Part No.

Reference dimensions of 10-32UNF and NPT threads after installation. 15-9-47 6 Series AS-FG Dimensions: Universal Type Applicable tubing O.D. d (Hexagon width across flats) Applicable tubing O.D. d M5 type U10/32 type (Hexagon width across flats) Metric Size Inch Size Model d T Weight (g) H D1 D2 L1 L2 L3 L5 A Model d T Weight (g) H D1 D2 L1 L2 L3 L5 A D3 L4 Max. Min. Max. Min.

Precautions mm : D 6 D 1 mm, 6 < D 25 D 2 mm, D > 25 D 4 mm inch : D 0.23 D 0.04 inch, 0.23 < D 0.98 D 0.08 inch, D > 0.98 D 0.16 inch 3. In the case of double rod type and single acting retraction type, enter the dimensions when the rod is retracted. 4. Only the single side of a double rod is able to manufacture. 1.

9.5 18.5 22.5 44.5 49.5 47 43.5 50 58 82 85 88.5 D-F9ll 7 16 20 42 47 44.5 42.5 49 57 81 84 87.5 D-F9lWl 6 15 19 41 46 43.5 4.4-16

Operating Range (mm) Auto switch model Bore size (mm) 9.5 9.5 11.5 12 20 32 40 50 63 D-A9(V) 7 9 9.5 D-M9(V) D-M9W(V) D-M9A(V) 2.5 4 6 6 6 6.5 D-A7(H)(C) D-A80(H)(C) 9.5 12 12 11 10 12 D-A79W 11.5 13 13 14 14 16 D-F7(V) D-J79(C) D-F7W(V) D-F7BA(V) D-F7NT D-F79F 4 5.5 6 6 6 6.5 D-X Since the operating range is provided as a guideline including hysteresis, it cannot be guaranteed (assuming

PW 0 0 0 1 1 1 9 9 9 PW LRUN 2 2 2 8 8 8 3 3 3 7 7 7 4 4 4 6 6 6 SD RD LERR. 5 5 5 L RUN SD RD x10 x1 24V 0V +24V 24G DA DB FG DG L ERR.

No. 1 FG FG GW 1 2 3 4 5 2 0V GW 3 C24V 4 EMGEMG 5 EMG+ EMG () Phoenix Contact (SZS0.42.0) SMC LEC-D-1-1 FK-MC0.5/5-ST-2.5(Phoenix Contact ) GW (CN4) FG GW LEC 0V GW FG CN4 DC24V () 0V LEC 24V DC24V CN1 0V 24V OV 28 - GW LEC (OV) UL UL1310 Class2 D (100) GW GW GW D 6.2 2) AWG20 (0.5mm (24V0V) *60 2) EMG AWG20 (0.5mm (EMG+,EMG-) *60 2) FG AWG20 (0.5mm *60 2.0 8mm

D3 D1 AS-F AS-F TMH M L3 ASD AS L4 D2 L5 A AS-FE KE AS-FG T AS-FP L2 L1 H (Width across flats) AS-FM AS-D Metric Size [mm] Model d T Uni thread H D1 D2 D3 L1 L2 L3 L4 L5 Note 1) A Note 2) M Weight [g] Unlocked Locked Unlocked Locked AS23l1F-U01-23A 3.2 AS-T 13.3 24 17.5 36 30.6 29.2 25.8 24.4 13.3 9 AS23l1F-U01-04A 4 8.2 13.9 25.1 AS23l1F-U01-06A 6 10.4 26.2 20.4 38.8 10 AS23l1F-U01-08A 8

Communication connector D-sub 9 pin (socket) Holding screw: M2.6 6 Contact a for output cutoff alarm (open when alarm occurs) 7 Common for output cutoff alarm 9 15 10 11 12 13 14 Pin no.

(A contact) D-F9N D-F9P D-F9G D-F9H D-F9GL D-F9HL D-F9B D-F9NL D-F9PL D-F9BL N.O. (A contact) 1 2 1 pc. 2 pcs. N.C. (B contact) N.C. (B contact) None Nil Auto/Proximity switch type N.C. (B contact) 6 6 pcs. Refer to the table on the right for auto/proximity switch part numbers.