Time delay valve series VR2110 with its combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a fixed time period.Transmitter-relay valve, metric threads, Fluid: air, Operating pressure: 0 to 1.0MPa, Effective area (Cv): 7mm (0.38), Port size: Rc (PT) 1/8, VALVE, RELAY, DBL PORT, VALVE, VR CHECK VALVE, DI, VR BODY PT 1/8, .78248 lb, FunctionSub-plateModelIndicatorDouble
Time delay valve series VR2110 with its combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a fixed time period.Transmitter-relay valve, North American threads, Fluid: air, Operating pressure: 0 to 1.0MPa, Effective area (Cv): 7mm (0.38), Port size: NPT 1/8, VALVE, RELAY, SGL PORT, VALVE, VR CHECK VALVE, CI, VR BODY PT 1/8NPT, .66000 lb,
Time delay valve series VR2110 with its combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a fixed time period.3 port check valve, Max. operating pressure: 1.0MPa, Ambient and fluid temp: -5 to 60C, Effective area (Cv): 0.38 to 0.81, SHUTTLE VALVE, CLEAN ROOM, VALVE, VR CHECK VALVE, F5, VR BODY PT 1/4, .00000 lb
Time delay valve series VR2110 with its combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a fixed time period.Transmitter-relay valve, metric threads, Fluid: air, Operating pressure: 0 to 1.0MPa, Effective area (Cv): 7mm² (0.38), Port size: Rc (PT) 1/8, VALVE, RELAY, CHECK VALVE, J87, 0.35 lb
Time delay valve series VR2110 with its combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a fixed time period.Supply pressure: 0 to 1.0 MPa, Signal pressure: 0.25 to 0.8MPa, Time delay: 0.5 to 60s, Operating and fluid temp: -5° to 60°C (no freezing), Effective area (Cv): 0.14, TIME DELAY VALVE, CHECK VALVE, J87, 0.5 lb
Time delay valve series VR2110 with its combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a fixed time period.Transmitter-relay valve, metric threads, Fluid: air, Operating pressure: 0 to 1.0MPa, Effective area (Cv): 7mm² (0.38), Port size: Rc (PT) 1/8, RELAY VALVE DBL, BOTTOM PIPING, CHECK VALVE, 0.3 lb
Time delay valve series VR2110 with its combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a fixed time period.Transmitter-relay valve, metric threads, Fluid: air, Operating pressure: 0 to 1.0MPa, Effective area (Cv): 7mm² (0.38), Port size: Rc (PT) 1/8, VALVE, RELAY,DBL PORT, CHECK VALVE, J87, 0.3 lb
Time delay valve series VR2110 with its combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a fixed time period.3 port check valve, Max. operating pressure: 1.0MPa, Ambient and fluid temp: -5° to 60°C, Effective area (Cv): 0.38 to 0.81, SHUTTLE VALVE, CHECK VALVE, J87, 0.02400 lb
Transmitter / Time Delay Valve VR2110 Series operates in a similar way to an electrical time delay relay.Features· The combination of an adjustable orifice and fixed flow allows the transmission of a pneumatic signal after a fixed time period (delay).
Time delay valve series VR2110 with its combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a fixed time period. Supply pressure: 0 to 1.0 MPa; Signal pressure: 0.25 to 0.8MPa; Time delay: 0.5 to 60s; Operating and fluid temp: -5° to 60°C (no freezing); Effective area (Cv): 0.14
Time delay valve series VR2110 with its combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a fixed time period. Maximum operating pressure: 1MPa (145 psi); Minimum operating pressure: 0.05MPa (7 psi); Proof pressure: 1.5MPa (218 psi); Ambient and fluid temp: -5° to 60°C (23° to 140°F) (with no freezing)
Time delay valve series VR2110 with its combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a fixed time period. Transmitter-relay valve, metric threads; Fluid: air; Operating pressure: 0 to 1.0MPa; Effective area (Cv): 7mm² (0.38); Port size: Rc (PT) 1/8
Time delay valve series VR2110 with its combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a fixed time period. Maximum operating pressure: 1MPa (145 psi); Minimum operating pressure: 0.05MPa (7 psi); Proof pressure: 1.5MPa (218 psi); Ambient and fluid temp: -5° to 60°C (23° to 140°F) (with no freezing)
Time delay valve series VR2110 with its combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a fixed time period. 3 port check valve; Max. operating pressure: 1.0MPa; Ambient and fluid temp: -5° to 60°C; Effective area (Cv): 0.38 to 0.81
Time delay valve series VR2110 with its combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a fixed time period.3 port check valve; Max. operating pressure: 1.0MPa; Ambient and fluid temp: -5° to 60°C; Effective area (Cv): 0.38 to 0.81
Time delay valve series VR2110 with its combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a fixed time period.Transmitter-relay valve, North American threads; Fluid: air; Operating pressure: 0 to 1.0MPa; Effective area (Cv): 7mm² (0.38); Port size: NPT 1/8
Time delay valve series VR2110 with its combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a fixed time period.3 port check valve; Max. operating pressure: 145 psi; Ambient and fluid temp: 23° to 140°F; Effective area (Cv): 0.38 to 0.81
Time delay valve series VR2110 with its combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a fixed time period.Supply pressure: 0 to 145 psi; Signal pressure: 36.25 to 116 psi; Time delay: 0.5 to 60s; Operating and fluid temp: 23° to 140°F (no freezing); Effective area (Cv): 0.14
Time delay valve series VR2110 with its combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a fixed time period.Supply pressure: 0 to 1.0 MPa; Signal pressure: 0.25 to 0.8MPa; Time delay: 0.5 to 60s; Operating and fluid temp: -5° to 60°C (no freezing); Effective area (Cv): 0.14
Time delay valve series VR2110 with its combination of adjustable orifice and fixed flow allows transmission of a pneumatic signal after a fixed time period. 3 port check valve; Max. operating pressure: 1.0MPa; Ambient and fluid temp: -5° to 60°C; Effective area (Cv): 0.38 to 0.81